protection device
Recently Published Documents


TOTAL DOCUMENTS

846
(FIVE YEARS 227)

H-INDEX

23
(FIVE YEARS 2)

2021 ◽  
Vol 70 (12) ◽  
pp. 2041-2045
Author(s):  
Seung-Jin Kim ◽  
Jae-Ho Hur ◽  
Tae-Hyun Kim ◽  
Young-Il Kim ◽  
Hosung Jung

2021 ◽  
Author(s):  
Shunzou Ohshima

<p>・Table 1 shows the evaluation results of four types (05-</p><p>T125, (05-T-40), (05-L125A), (05-L-40A)) in a 500V power supply. Table 2 shows the evaluation results of four types (10-T125, (10-T-40), (10-L125A), (10-L-40A)) in a 1000V power supply.<br></p><p>・Figure 5 and Table 3 show the waveform and data of 05-T125. Fig. 6 and Table 4 show the waveform and data of 10-L-40A.</p><p>・ All eight types of waveforms, including those with (), are attached together in a separate document.</p><p><br></p>


2021 ◽  
Author(s):  
Shunzou Ohshima

<p>・Table 1 shows the evaluation results of four types (05-</p><p>T125, (05-T-40), (05-L125A), (05-L-40A)) in a 500V power supply. Table 2 shows the evaluation results of four types (10-T125, (10-T-40), (10-L125A), (10-L-40A)) in a 1000V power supply.<br></p><p>・Figure 5 and Table 3 show the waveform and data of 05-T125. Fig. 6 and Table 4 show the waveform and data of 10-L-40A.</p><p>・ All eight types of waveforms, including those with (), are attached together in a separate document.</p><p><br></p>


2021 ◽  
Vol 2137 (1) ◽  
pp. 012045
Author(s):  
Aihua Liu ◽  
Shuning Ma

Abstract Zinc oxide arrester is often used as lightning protection device in 10KV distribution network. In order to check the reliable operation of the zinc oxide arrester, preventive tests are often carried out. In this project, the intelligent tester adopts high-precision clamp current mutual inductance technology as the front-end acquisition mode of current signals; Magnetic isolation technology is used to ensure the accuracy of current and voltage sampling and the anti-interference ability and testing accuracy of the instrument are improved by using fast Fourier transform for data processing. The integrated application of several technologies provides a basis for judging the operating state of the 10kV zinc oxide arrester. The charged measurement of operating parameters of 10kV zinc oxide arrester is realized and the measurement efficiency is improved.


Author(s):  
A. A. Sidorov ◽  
V. I. Abolmasov ◽  
K. O. Kosolapov ◽  
A. V. Kuznetsov ◽  
M. A. Arkhipov
Keyword(s):  

2021 ◽  
Author(s):  
D. A. Stepanova ◽  
V. I. Antonov ◽  
V. A. Naumov ◽  
A. V. Soldatov
Keyword(s):  

2021 ◽  
Author(s):  
Yan Huang ◽  
Yu Feng Gao ◽  
Yong Liu ◽  
Hao Bai ◽  
Xing Yu Xiang