blind zone
Recently Published Documents


TOTAL DOCUMENTS

110
(FIVE YEARS 37)

H-INDEX

13
(FIVE YEARS 2)

Author(s):  
Lei Han ◽  
Peng Zheng ◽  
Haobo Li ◽  
Jiangfan Chen ◽  
Zexi Hua ◽  
...  

2021 ◽  
Author(s):  
Jingru Wang ◽  
Yuehe Ge ◽  
Zhizhang (David) Chen ◽  
Zhimeng Xu ◽  
Hai Zhang

Abstract Optical metasurfaces are researched more and more intensively for the possible realization of lightweight and compact optical devices with novel functionalities. In this paper, a new beam-steering system based on double metasurface lenses (metalenses) is proposed and developed. The proposed system is lightweight, small volume, low cost, and easy to integrate. The exact forward and inverse solutions are derived respectively using the generalized Snell’s law of refraction. Given the orientations of the double metalenses, the pointing position can be accurately determined. If the desired pointing position is given, the required metalenses’ orientations can be obtained by applied global optimization algorithms to solve nonlinear equations related to the inverse problem. The relationships of the scan region and blind zone with the system parameters are derived. The method to eliminate the blind zone is given. Comparison with double Risley-prism systems is also conducted. This work provides a new approach to control light beams.


2021 ◽  
pp. 3721-3733
Author(s):  
Xiaoju Yong ◽  
Tao Zhang ◽  
Ming Hao ◽  
Xiangyan Luo
Keyword(s):  

2021 ◽  
Author(s):  
Lisha Fan ◽  
Shuowen Zhang ◽  
Qingyu Yan ◽  
Jian Lin ◽  
Qunli Zhang ◽  
...  
Keyword(s):  

Author(s):  
Zhenxing Li ◽  
Jialing Wan ◽  
Pengfei Wang ◽  
Hanli Weng ◽  
Zhenhua Li

AbstractFault section location of a single-phase grounding fault is affected by the neutral grounding mode of the system, transition resistance, and the blind zone. A fault section locating method based on an amplitude feature and an intelligent distance algorithm is proposed to eliminate the influence of the above factors. By analyzing and comparing the amplitude characteristics of the zero-sequence current transient components at both ends of the healthy section and the faulty section, a distance algorithm with strong abnormal data immune capability is introduced in this paper. The matching degree of the amplitude characteristics at both ends of the feeder section are used as the criterion and by comparing with the set threshold, the faulty section is effectively determined. Finally, simulations using Matlab/Simulink and PSCAD/EMTDC show that the proposed section locating method can locate the faulty section accurately, and is not affected by grounding mode, grounding resistance, or the blind zone.


Sign in / Sign up

Export Citation Format

Share Document