relay coordination
Recently Published Documents


TOTAL DOCUMENTS

240
(FIVE YEARS 81)

H-INDEX

22
(FIVE YEARS 4)

Energies ◽  
2021 ◽  
Vol 14 (21) ◽  
pp. 7192
Author(s):  
Aayush Shrivastava ◽  
Abhishek Sharma ◽  
Manjaree Pandit ◽  
Vibhu Jately ◽  
Brian Azzopardi

A directional overcurrent relay is commonly used to protect the power distribution networks of a distributed system. The selection of the appropriate settings for the relays is an important component of the protection strategies used to isolate the faulty parts of the system. The rapid growth of distributed generation (DG) systems present new challenges to these protection schemes. The effect of solar photovoltaic power plants on relay coordination is studied initially in this research work. A protection strategy was formulated to guarantee that the increased penetration of solar photovoltaic (PV) plants does not affect the relay coordination time. This paper addresses these issues associated with a high penetration of DG through the use of a hybrid protection scheme. The protection strategy is divided into two parts. The first part is based on an optimal fault current limiter value estimated with respect to constraints and the optimal time multiplier setting, and then the coordination time interval is estimated with respect to constraint in Part II. The results of these analyses show that a hybrid protection scheme can effectively handle the complexity of distributed generation (DG) and dynamic relay coordination problems. In this research, three optimization algorithms have been used for calculating the estimated value of impedance fault current limiter (Zfcl) and time multiplier setting (TMS). The response time of hybrid protection schemes is very important. If the computational time of their proposed algorithms is less than their actual computational time, then their response time to address the issue is also less. The performance in all algorithms was identified to arrive at a conclusion that the grey wolf optimized algorithm (GWO) algorithm can substantially reduce the computational time needed to implement hybrid protection algorithms. The GWO algorithm takes a computational time of 0.946 s, achieving its feasible solution in less than 1 s.


Author(s):  
Sanjay Varghese John ◽  
Mabel Ebenezer

Energies ◽  
2021 ◽  
Vol 14 (18) ◽  
pp. 5603
Author(s):  
Muhammad Irfan ◽  
Abdul Wadood ◽  
Tahir Khurshaid ◽  
Bakht Muhammad Khan ◽  
Ki-Chai Kim ◽  
...  

The relay coordination problem is of dire importance as it is critical to isolate the faulty portion in a timely way and thus ensure electrical network security and reliability. Meanwhile a relay protection optimization problem is highly constraint and complicated problem to be addressed. To fulfill this purpose, Harris Hawk Optimization (HHO) is adapted to solve the optimization problem for Directional Over-current Relays (DOCRs) and numerical relays. As it is inspired by the intelligent and collegial chasing and preying behavior of hawks for capturing the prey, it shows quite an impressive result for finding the global optimum values. Two decision variables; Time Dial Settings (TDS) and Plug Settings (PS) are chosen as the decision variables for minimization of overall operating time of relays. The proposed algorithm is implemented on three IEEE test systems. In comparison to other state-of-the-art nature inspired and traditional algorithms, the results demonstrate the superiority of HHO.


2021 ◽  
Author(s):  
Mert Bekir Atsever ◽  
Ozgur Karacasu ◽  
Mehmet Hakan Hocaoglu