Abstract The power output of plasma experiments and fusion reactors is a crucial parameter. It is determined by neutron yields that are proportional and directly related to the fusion yield. The number of emitted neutrons should be known for safety reasons and for neutron budget management. The PF-1000 is the large plasma facility based on the plasma focus phenomenon. PF-1000 is operating in the Institute of Plasma Physics and Laser Microfusion in Warsaw. Neutron yield changes during subsequent pulses, which is immanent part of this type device and so it must be monitored in terms of neutron emission. The reference diagnostic intended for this purpose is the silver activation counter (SAC) used for many years. Our previous studies demonstrated the applicability of radio-yttrium for neutron yield measurements during the deuterium campaign on the PF-1000 facility. The obtained results were compared with data from silver activation counter and shown linear dependence but with some protuberances in local scale. Correlation between results for both neutron monitors was maintained. But the yttrium monitor registered the fast energy neutron that reached measurement apparatus directly from the plasma pinch. Based on the preliminary experiences, the yttrium monitor was designed to automatically register neutron-induced yttrium activity. The MCNP geometrical model of PF-1000 and yttrium monitor were both used for calculation of the activation coefficient for yttrium. The yttrium monitor has been established as the permanent diagnostic for monitoring fusion reactions in the PF-1000 device.



Author(s):  
Sahar Rajabi Moghadam ◽  
Fereydoon Abbasi Davani ◽  
Babak Shirani Bidabadi

A silver activation counter has been constructed by plastic scintillator plates along with silver foils for determination the neutron yield of a 2.48kJ plasma focus device, SBUPF1. This counter was calibrated by source removal method with an Am-Be 5 Ci neutron source which was placed above the anode of plasma focus device. Deuterium gas up to 8mbar pressure was injected to this device, and the neutron yield produced by pulsed D-D fusion of plasma focus device was measured by the counter. the neutron yield of SBUPF1 in 8mbar pressure was obtained 3.71±0.32×107 neutrons per shot. This result has relatively agreed with the neutron yield measured by silver activation Geiger counters.



Sign in / Sign up

Export Citation Format

Share Document