Nukleonika
Latest Publications


TOTAL DOCUMENTS

363
(FIVE YEARS 46)

H-INDEX

10
(FIVE YEARS 3)

Published By De Gruyter Open Sp. Z O.O.

0029-5922

Nukleonika ◽  
2021 ◽  
Vol 66 (1) ◽  
pp. 35-44
Author(s):  
Abdulsalam M. Alhawsawi ◽  
E. I. Shababa ◽  
Maher M. T. Qutub ◽  
Essam M. Banoqitah ◽  
A. A. Kinsara

AbstractIt is a known fact that phosphate rocks have high levels of natural radioactivity due to the presence of large concentrations of radionuclides. This work aims to estimate radiation exposure and dose levels at Al-Jalamid site in northern Saudi Arabia. Al-Jalamid area is one of the largest reserves of phosphate worldwide. Ma’aden, a Saudi Government public company, owns the mine and is responsible for all mining activities. Phosphate and soil samples collected from Al-Jalamid phosphate mining area have been analysed for their uranium and thorium content by an α-spectrometer using radiochemical techniques. The quantity of radon gas was measured both in groundwater and in the atmosphere (indoor and outdoor) at the site using a portable radiation survey instrument. Groundwater samples collected from wells surrounding the mining area were analysed using a liquid scintillation counter in addition to an α-spectrometer. Finally, it is found that phosphate rock concentrate products cannot be utilized economically based on the standards set by the International Atomic Energy Agency (IAEA), since the average activity concentration does not reach the limit set by IAEA and hence are not commercially feasible.


Nukleonika ◽  
2021 ◽  
Vol 66 (1) ◽  
pp. 29-34
Author(s):  
Anna Turek-Fijak ◽  
Joanna Brania ◽  
Katarzyna Styszko ◽  
Damian Zięba ◽  
Zdzisław Stęgowski ◽  
...  

Abstract The purpose of this study is to analyse the elements and PM10 concentrations in air samples gathered in the winter of 2017/2018 in two small towns, namely Skala and Wadowice. The chemical elements were identified for each sample using the energy dispersive X-ray method. The spectrometer was equipped, among others, with an Mo-X-ray tube which was the source of the photons and the Si(Li) detector. The following chemical elements: Cl, K, Fe, Ca, Zn, Pb, Br, Ti, Cu, Mn, V, Co, Rb, Ni, Sr, and Cr were identified in the samples. In addition, As and Se were identified in Wadowice. First, the results were compared with each other and then with the results for the nearest city. It was observed that the PM10 concentrations were significantly higher than the UE limit value for PM10, which equals 50 μg·m−3 per 24 h. Moreover, the high concentrations of, among others, K, Pb, Cl or Zn, are likely to be linked with fossil fuels combustion and biomass burning. The levels of element concentrations in Wadowice and Skala resemble the levels observed several years earlier in Krakow.


Nukleonika ◽  
2021 ◽  
Vol 66 (1) ◽  
pp. 3-9
Author(s):  
Krystyna A. Cieśla ◽  
Anna Abramowska

Abstract The paper discusses the effect of ionizing radiation on the functional properties of the biodegradable starch:PVA films. The analysis is related to the possible use of the material for packing the products (particularly, food) that are predicted for radiation decontamination and to the potential modification of the material by radiation treatment. Our previous results have shown that the influence of ionizing radiation on the films’ properties varied for the specific compositions (differing in starch:PVA ratio or the type of substrates) and depended on irradiation conditions. However, these studies considered only the irradiation performed in gamma chamber or in e-beam using a dose of 25 kGy. Therefore, the present study deals with the effect of the irradiations performed using various doses on the selected promising starch:PVA composition. The films characterized by starch:PVA weight ratio of 45:55 was obtained by solution casting and irradiated with fast electrons in air and with 60Co gamma rays in nitrogen applying the doses of 5, 10, 20, 25, 30, 50, and 75 kGy. No regular dependence has been noticed between the composition of films (differing in the starch and PVA content) and the intensities of the particular bands in the UV-VIS DRS spectra after irradiation. The results indicated strong interaction of the starch and PVA components in the films and the occurrence of specific reactions in each composition upon irradiation. No special differences were observed between tensile strength and Young’s modulus of the non-irradiated films characterized by the starch:PVA ratio equal to 45:55 and the samples irradiated using doses in the range of 5–75 kGy. Similarly, no differences were observed in both cases between the swelling capability of the non-irradiated and the irradiated films. However, it can be deduced that solubility in water increased when the radiation dose increased. The results show that using the doses till the range 25 kGy does not cause an essential change of all the examined properties of the starch:PVA (45:55) films. Accordingly, starch:PVA (45:55) films might be considered suitable for packing food predicted for radiation decontamination.


Nukleonika ◽  
2021 ◽  
Vol 66 (1) ◽  
pp. 11-19
Author(s):  
Aslina Br. Ginting ◽  
Amini Siti ◽  
Noviarty ◽  
Yanlinastuti ◽  
Arif Nugroho ◽  
...  

Abstract Characterization of natural salts from Bayah, Lampung, and Tasikmalaya, Indonesia has been carried out as a substitute for synthetic resins. The characteristics include zeolite activation with NH4Cl, and heated at 200°C, the bond stability test of 137Cs-zeolite, chemical composition analysis, surface area, pore size, analysis of Cs cation exchange capacity (CEC), diffusion coefficient (Di ), activation energy (Ea ), and absorption of three zeolites. To do this, pipette 50 μl of a standard solution of 137Cs from the National Institute of Standards and Technology (NIST), put in, 2 ml of 0.1 N HCl, and then add 1 g of zeolite and stir each for 1, 2, 3, 4, 5, and 24 h. Based on this stirring time, the 137C isotope will exchange ions with NH4-zeolite to 137Cs-zeolite in the solid phase. The content of 137Cs in 137Cs-zeolites (solid phase) was analysed using a gamma spectrometer. The results of the chemical composition analysis showed that the character of zeolite from Lampung has a Si/Al ratio, with a CEC value of 1.448 mEq/g which is greater than Bayah and Tasikmalaya, while the Di and Ea values for the three select types were obtained almost the same. Moreover, the stability test of the Cs ion bond with zeolite showed no significant release of Cs ions from the zeolite structure. It can be concluded that the three soloists tested that the zeolite from Lampung has better characters. The results of 137Cs isotope separation in 150 μl of U3Si2/Al fuel solution post-irradiation using zeolite from Lampung and Dowex resins obtained almost the same recovery around 98–99%, so it can be concluded that zeolite from Lampung can be used as a substitute for synthetic resin in the cation exchange process for the 137Cs isotope in nuclear fuel post-irradiated.


Nukleonika ◽  
2021 ◽  
Vol 66 (1) ◽  
pp. 21-27
Author(s):  
Mohammed Siddig H. Mohammed ◽  
Essam M. Banoqitah ◽  
Ezzat Elmoujarkach ◽  
Abdulsalam M. Alhawsawi ◽  
Fathi Djouider

Abstract Radioactive sealed sources and radiotracer techniques are used to diagnose industrial process units. This work introduces a workspace to simulate four sealed sources and radiotracer applications, namely, gamma scanning of distillation columns, gamma scanning of pipes, gamma transmission tomography, and radiotracer flow rate measurements. The workspace was created in Geant4 Application for Tomographic Emission (GATE) simulation toolkit and was called Industrial Radioisotope Applications Virtual Laboratory. The flexibility of GATE and the fact that it is an open-source software render it advantageous to radioisotope technology practitioners, educators, and students. The comparison of the simulation results with experimental results that are available in the literature showed the effectiveness of the virtual laboratory.


Nukleonika ◽  
2020 ◽  
Vol 65 (4) ◽  
pp. 211-215
Author(s):  
Sarwat Zahra ◽  
Bushra Shafaq ◽  
Bushra Kanwal ◽  
Nosheen Akbar

AbstractBy considering energy-dependent form factors extracted from generalized Chou–Yang model, root mean square (rms) charge radii of deuteron and helium nuclei (alpha) are predicted at different values of center of mass energy which are in good agreement with theoretical predictions and experimental results. The rms radius is inversely proportional to mass of nuclei. Besides, the relationship between radii and energy are also derived.


Nukleonika ◽  
2020 ◽  
Vol 65 (4) ◽  
pp. 223-227
Author(s):  
Piotr Sobotka ◽  
Bartłomiej Kliś ◽  
Zuzanna Baranowska ◽  
Katarzyna Wołoszczuk ◽  
Katarzyna Rutkowska ◽  
...  

AbstractThe aim of this experimental work was to examine whether semiconductor photodetectors may be applied for the efficient reading of thermoluminescent dosimeter (TLD) signals. For this purpose, a series of experiments have been performed at the Department of Physics, Warsaw University of Technology, in cooperation with the Central Laboratory for Radiological Protection (CLOR). Specifically, the measurement system proposed here has been designed to detect a signal from TLDs that use a semiconductor detector operating in conditions analogous to those met when using commercial devices equipped with a classic photomultiplier. For the experimental tests, the TLDs were irradiated with a beam of 137Cs radiation in the accredited Laboratory for Calibration of Dosimetric and Radon Instruments. Eventually, a comparison of the results obtained with a semiconductor detector (ID120) and a commercial TLD reader with a photomultiplier tube (RADOS) were made.


Nukleonika ◽  
2020 ◽  
Vol 65 (4) ◽  
pp. 229-232
Author(s):  
Józef Bogowicz ◽  
Mariusz Chabera ◽  
Wojciech Dziewiecki ◽  
Kacper Kaźmierczak ◽  
Jan Klimaszewski ◽  
...  

AbstractThe new vehicle scanning system Sowa has been developed in the National Centre for Nuclear Research. This innovative device is equipped with a 300 kV X-ray tube, U-shape imaging detector line, transport system, and fully shielded container. Sowa allows for a detailed inspection of the car and the detection of illegal transported items. This article presents the design, applied solutions, and achieved results of Sowa scanning system.


Nukleonika ◽  
2020 ◽  
Vol 65 (4) ◽  
pp. 205-210
Author(s):  
Jan Wild ◽  
Peter Pira ◽  
Tomas Burian ◽  
Ludek Vysin ◽  
Libor Juha ◽  
...  

AbstractExtreme ultraviolet (XUV) capillary-discharge lasers (CDLs) are a suitable source for the efficient, clean ablation of ionic crystals, which are obviously difficult to ablate with conventional, long-wavelength lasers. In the present study, a single crystal of cesium iodide (CsI) was irradiated by multiple, focused 1.5-ns pulses of 46.9-nm radiation delivered from a compact XUV-CDL device operated at either 2-Hz or 3-Hz repetition rates. The ablation rates were determined from the depth of the craters produced by the accumulation of laser pulses. Langmuir probes were used to diagnose the plasma plume produced by the focused XUV-CDL beam. Both the electron density and electron temperature were sufficiently high to confirm that ablation was the key process in the observed CsI removal. Moreover, a CsI thin film on MgO substrate was prepared by XUV pulsed laser deposition; a fraction of the film was detected by X-ray photoelectron spectroscopy.


Nukleonika ◽  
2020 ◽  
Vol 65 (4) ◽  
pp. 217-222
Author(s):  
Monika Paluch-Ferszt ◽  
Beata Kozłowska ◽  
Marcin Dybek

AbstractThe aim of the present study is to compare dose distributions and their verification in target areas and organs at risk (OAR) in conformal and volumetric modulated arc therapy (VMAT) techniques. Proper verification procedures allow the removal of the major sources of errors, such as incorrect application of a planning system, its insufficient or cursory commissioning, as well as an erroneous interpretation of the obtained results. Three target areas (head and neck, chest, and pelvic) were selected and the treatment was delivered based on plans made using collapsed cone convolution and Monte Carlo algorithms with 6-MV photon beams, adopting conformal and VMAT techniques, respectively. All the plans were prepared for the anthropomorphic phantom. Dose measurements were performed with TL detectors made of LiF phosphor doped with magnesium and titanium (LiF:Mg,Ti). This paper presents the results of TL measurements and calculated doses, as well as their deviations from the treatment planning system (TPS) in the three planned target areas. It was established that the algorithms subject to analysis differ, particularly in dose calculations for highly inhomogeneous regions (OAR). Aside from the need to achieve the dose intended for the tumour, the choice of irradiation technique in teleradiotherapy should be dictated by the degree of exposure to individual critical organs during irradiation. While nothing deviated beyond the bounds of what is acceptable by international regulatory bodies in plans from TPS, clinically one must be more cautious with the OAR areas.


Sign in / Sign up

Export Citation Format

Share Document