coupler device
Recently Published Documents


TOTAL DOCUMENTS

36
(FIVE YEARS 11)

H-INDEX

6
(FIVE YEARS 1)

Author(s):  
Joshua Rezkalla ◽  
Majid Husain ◽  
Ginger Slack ◽  
Sanjay Sinha

Refractory post-operative chylothorax in congenital heart disease is difficult to treat. We present a case of intractable neonatal chylothorax after cardiac surgery due to central lymphatic flow disorder that was treated by creating a lymphovenous anastomosis of the thoracic duct to the left external jugular vein for definitive treatment


2021 ◽  
Vol 1885 (5) ◽  
pp. 052019
Author(s):  
Bo Yang ◽  
Huanjun Liu ◽  
Jun Yin
Keyword(s):  

2020 ◽  
Vol 4 (4) ◽  
pp. 1-5
Author(s):  
Sherif Sultan ◽  
Mohamed K E Mustafa ◽  
Nora Barrett ◽  
Niamh Hynes

Abstract Background  Resistant and uncontrolled hypertension prominently amplifies the risk of end-stage renal disease and fatal cardiovascular events. Therapeutic inertia, despite maximum tolerated anti-hypertensive medications, puts patients at high risk, thus non-pharmacologic therapies have been proposed. The ROX arteriovenous coupler (ROX, Medical Inc., San Clemente, CA, USA), initially developed for treatment of chronic obstructive pulmonary disease, exploits the biomechanical effects of diverting arterial blood into a low-resistance, high-compliance venous segment, thereby decreasing arterial vascular resistance and blood pressure (BP). Case summary  A 76-year-old male, non-smoker and non-diabetic with resistant primary hypertension presented to our institution with disabling claudication, lower limb swelling and right hip pain. He had concomitant saccular abdominal aortic and right iliac aneurysms. He had previously undergone renal denervation on two separate occasions yet continued to require increasing anti-hypertensive medications. He subsequently had an insertion of an ROX coupler device between his right external iliac artery and vein after failure of insertion into his left iliac system. He developed right hip and buttock pain and consequently underwent a total hip replacement and subsequent revision, which did not alleviate his symptoms. Ankle-brachial indices were reduced to 0.70 on the right limb and normal on the left. Insertion of the ROX coupler device was reversed with concomitant endovascular aortic repair. Discussion  There is no clear consensus on reversal of the ROX coupler device. Endovascular aortic repair reversal of the ROX coupler device in this case was safe, effective, and improved symptoms including patient’s BP control and limb symptoms


2020 ◽  
Vol 1 (2) ◽  
Author(s):  
Oded Goren ◽  
Raghuram Sampath ◽  
Akshal S Patel ◽  
Christoph J Griessenauer ◽  
Clemens M Schirmer ◽  
...  

ABSTRACT BACKGROUND AND IMPORTANCE The Coupler microanastomotic device (Medical Companies Alliance, Birmingham, Alabama) aims at facilitating safe and efficient end-to-end reconstruction of the native vessel ends following resection of intracranial aneurysms. CLINICAL PRESENTATION We report the first case of the Coupler device used to treat a ruptured posterior inferior cerebellar artery (PICA) aneurysm. Following aneurysmal trapping and excision, the native parent vessel ends were connected in an end-to-end fashion. CONCLUSION The microanastomotic Coupler device is an acceptable option for end-to-end anastomosis and was successfully applied in the management of a ruptured fusiform PICA aneurysm.


Microsurgery ◽  
2020 ◽  
Vol 40 (5) ◽  
pp. 608-617 ◽  
Author(s):  
Michele Maruccia ◽  
Giusy Fatigato ◽  
Rossella Elia ◽  
Luigi Amerigo Ragusa ◽  
Michelangelo G. Vestita ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document