electron event
Recently Published Documents


TOTAL DOCUMENTS

24
(FIVE YEARS 8)

H-INDEX

8
(FIVE YEARS 1)

2021 ◽  
Vol 27 (S1) ◽  
pp. 188-189
Author(s):  
Philipp Pelz ◽  
Peter Ercius ◽  
Colin Ophus ◽  
Ian Johnson ◽  
Mary Scott

2020 ◽  
Vol 900 (2) ◽  
pp. L16
Author(s):  
G. Li ◽  
L. Zhao ◽  
L. Wang ◽  
W. Liu ◽  
X. Wu

IUCrJ ◽  
2020 ◽  
Vol 7 (5) ◽  
pp. 860-869 ◽  
Author(s):  
Hui Guo ◽  
Erik Franken ◽  
Yuchen Deng ◽  
Samir Benlekbir ◽  
Garbi Singla Lezcano ◽  
...  

Direct detector device (DDD) cameras have revolutionized electron cryomicroscopy (cryoEM) with their high detective quantum efficiency (DQE) and output of movie data. A high ratio of camera frame rate (frames per second) to camera exposure rate (electrons per pixel per second) allows electron counting, which further improves the DQE and enables the recording of super-resolution information. Movie output also allows the correction of specimen movement and compensation for radiation damage. However, these movies come at the cost of producing large volumes of data. It is common practice to sum groups of successive camera frames to reduce the final frame rate, and therefore the file size, to one suitable for storage and image processing. This reduction in the temporal resolution of the camera requires decisions to be made during data acquisition that may result in the loss of information that could have been advantageous during image analysis. Here, experimental analysis of a new electron-event representation (EER) data format for electron-counting DDD movies is presented, which is enabled by new hardware developed by Thermo Fisher Scientific for their Falcon DDD cameras. This format enables the recording of DDD movies at the raw camera frame rate without sacrificing either spatial or temporal resolution. Experimental data demonstrate that the method retains super-resolution information and allows the correction of specimen movement at the physical frame rate of the camera while maintaining manageable file sizes. The EER format will enable the development of new methods that can utilize the full spatial and temporal resolution of DDD cameras.


Author(s):  
Hui Guo ◽  
Erik Franken ◽  
Yuchen Deng ◽  
Samir Benlekbir ◽  
Garbi Singla Lezcano ◽  
...  

AbstractDirect detector device (DDD) cameras have revolutionized electron cryomicroscopy (cryoEM) with their high detective quantum efficiency (DQE) and output of movie data. A high ratio of camera frame rate (frames/sec) to camera exposure rate (electrons/pixel/sec) allows electron counting, which further improves DQE and enables recording of super-resolution information. Movie output also allows for computational correction of specimen movement and compensation for radiation damage. However, these movies come at the cost of producing large volumes of data. It is common practice to sum groups of successive camera frames to reduce the final frame rate, and therefore file size, to one suitable for storage and image processing. This reduction in the camera’s temporal resolution requires decisions to be made during data acquisition that may result in the loss of information that could have been advantageous during image analysis. Here we present experimental analysis of a new Electron Event Representation (EER) data format for electron counting DDD movies, which is enabled by new hardware developed by Thermo Fisher Scientific for their Falcon DDD cameras. This format enables recording of DDD movies at the raw camera frame rate without sacrificing either spatial or temporal resolution. Experimental data demonstrate that the method retains super-resolution information and allows correction of specimen movement at the physical frame rate of the camera while maintaining manageable file sizes. The EER format will enable the development of new methods that can utilize the full spatial and temporal resolution of DDD cameras.


2019 ◽  
Vol 64 (9) ◽  
pp. 1825-1837
Author(s):  
Jian-zhao Wang ◽  
Ying Wang ◽  
Shu-wu Dai ◽  
Chen Wang ◽  
Ji-nan Ma ◽  
...  

2018 ◽  
Author(s):  
Veejendra Yadav ◽  
Dasari L V K Prasad ◽  
Arpita Yadav ◽  
Maddali L N Rao

<p>The torquoselectivity of conrotatory ring opening of 3-carbomethoxycyclobutene is controlled by p<sub>C1C2</sub>→s*<sub>C3C4</sub> and s<sub>C3C4</sub>→p*<sub>CO</sub> interactions in the transition state in a 4-electron process as opposed to only s<sub>C3C4</sub>→p*<sub>CO</sub> interaction in an apparently 8-electron event in 3-carbomethoxy-1,2-benzocyclobutene. The ring opening of 3-carbomethoxy-1,2-benzocyclobutene is sufficiently endothermic. We therefore argue that the reverse ring closing reaction is faster than the forward ring opening reaction and, thus, it establishes an equilibrium between the two and subsequently allows formation of the more stable species <i>via</i> outward ring opening reaction. Application of this argument to 3-dimethylaminocarbonyl-1,2-benzocyclobutene explains the predominantly observed inward opening.</p>


2018 ◽  
Author(s):  
Veejendra Yadav ◽  
Dasari L V K Prasad ◽  
Arpita Yadav ◽  
Maddali L N Rao

<p>The torquoselectivity of conrotatory ring opening of 3-carbomethoxycyclobutene is controlled by p<sub>C1C2</sub>→s*<sub>C3C4</sub> and s<sub>C3C4</sub>→p*<sub>CO</sub> interactions in the transition state in a 4-electron process as opposed to only s<sub>C3C4</sub>→p*<sub>CO</sub> interaction in an apparently 8-electron event in 3-carbomethoxy-1,2-benzocyclobutene. The ring opening of 3-carbomethoxy-1,2-benzocyclobutene is sufficiently endothermic. We therefore argue that the reverse ring closing reaction is faster than the forward ring opening reaction and, thus, it establishes an equilibrium between the two and subsequently allows formation of the more stable species <i>via</i> outward ring opening reaction. Application of this argument to 3-dimethylaminocarbonyl-1,2-benzocyclobutene explains the predominantly observed inward opening.</p>


Sign in / Sign up

Export Citation Format

Share Document