contrast imaging
Recently Published Documents


TOTAL DOCUMENTS

3513
(FIVE YEARS 802)

H-INDEX

83
(FIVE YEARS 10)

2022 ◽  
Vol 163 (2) ◽  
pp. 62
Author(s):  
E. Spalding ◽  
K. M. Morzinski ◽  
P. Hinz ◽  
J. Males ◽  
M. Meyer ◽  
...  

Abstract The Large Binocular Telescope (LBT) has two 8.4 m primary mirrors that produce beams that can be combined coherently in a “Fizeau” interferometric mode. In principle, the Fizeau point-spread function (PSF) enables the probing of structure at a resolution up to three times better than that of the adaptive-optics-corrected PSF of a single 8.4 m telescope. In this work, we examined the nearby star Altair (5.13 pc, type A7V, hundreds of Myr to ≈1.4 Gyr) in the Fizeau mode with the LBT at Brα (4.05 μm) and carried out angular differential imaging to search for companions. This work presents the first filled-aperture LBT Fizeau science data set to benefit from a correcting mirror that provides active phase control. In the analysis of the λ/D angular regime, the sensitivity of the data set is down to ≈0.5 M ⊙ at 1″ for a 1.0 Gyr system. This sensitivity remains limited by the small amount of integration time, which is in turn limited by the instability of the Fizeau PSF. However, in the Fizeau fringe regime we attain sensitivities of Δm ≈ 5 at 0.″2 and put constraints on companions of 1.3 M ⊙ down to an inner angle of ≈0.″15, closer than any previously published direct imaging of Altair. This analysis is a pathfinder for future data sets of this type, and represents some of the first steps to unlocking the potential of the first Extremely Large Telescope. Fizeau observations will be able to reach dimmer targets with upgrades to the instrument, in particular the phase detector.


2022 ◽  
Author(s):  
Zhongxing Zhou ◽  
Liqiang Ren ◽  
Kishore Rajendran ◽  
Felix E. Diehn ◽  
Joel G. Fletcher ◽  
...  

2022 ◽  
Vol 163 (2) ◽  
pp. 50
Author(s):  
Kyle Franson ◽  
Brendan P. Bowler ◽  
Timothy D. Brandt ◽  
Trent J. Dupuy ◽  
Quang H. Tran ◽  
...  

Abstract Model-independent masses of substellar companions are critical tools to validate models of planet and brown dwarf cooling, test their input physics, and determine the formation and evolution of these objects. In this work, we measure the dynamical mass and orbit of the young substellar companion HD 984 B. We obtained new high-contrast imaging of the HD 984 system with Keck/NIRC2 that expands the baseline of relative astrometry from 3 to 8 yr. We also present new radial velocities of the host star with the Habitable-Zone Planet Finder spectrograph at the Hobby-Eberly Telescope. Furthermore, HD 984 exhibits a significant proper motion difference between Hipparcos and Gaia EDR3. Our joint orbit fit of the relative astrometry, proper motions, and radial velocities yields a dynamical mass of 61 ± 4 M Jup for HD 984 B, placing the companion firmly in the brown dwarf regime. The new fit also reveals a higher eccentricity for the companion (e = 0.76 ± 0.05) compared to previous orbit fits. Given the broad age constraint for HD 984, this mass is consistent with predictions from evolutionary models. HD 984 B’s dynamical mass places it among a small but growing list of giant planet and brown dwarf companions with direct mass measurements.


2022 ◽  
Author(s):  
Samantha Alloo ◽  
David Paganin ◽  
Kaye Morgan ◽  
Timur Gureyev ◽  
Sheridan Mayo ◽  
...  

2022 ◽  
Vol 17 (01) ◽  
pp. P01004
Author(s):  
N. Clements ◽  
D. Richtsmeier ◽  
A. Hart ◽  
M. Bazalova-Carter

Abstract Computed tomography (CT) imaging with high energy resolution detectors shows great promise in material decomposition and multi-contrast imaging. Multi-contrast imaging was studied by imaging a phantom with iodine (I), gadolinium (Gd), and gold (Au) solutions, and mixtures of the three using a cadmium telluride (CdTe) spectrometer with an energy resolution of 1% as well as with a cadmium zinc telluride (CZT) detector with an energy resolution of 13%. The phantom was imaged at 120 kVp and 1.1 mA with 7 mm of aluminum filtration. For the CdTe data collection, the phantom was imaged using a 0.2 mm diameter x-ray beam with 96 ten-second data acquisitions across the phantom at 45 rotation angles. For the CZT detector, we had 720 projections using a cone beam, and the six detector energy thresholds were set to 23, 33, 50, 64, 81, and 120 keV so that three thresholds corresponded to the K-edges of the contrast agents. Contrast agent isolation methods were then examined. K-edge subtraction and novel spectrometric algebraic image reconstruction (SAIR) were used for the CdTe data. K-edge subtraction alone was used for the CZT data. Linearity plots produced similar R 2 values and slopes for all three reconstruction methods. Comparing CdTe methods, SAIR offered less noise than CdTe K-edge subtraction and better geometric accuracy at low contrast concentrations. CdTe contrast agent images of I, Gd, and Au offered less noise and greater contrast than the CZT images, highlighting the benefits of high energy resolution CdTe detectors for possible use in pre-clinical or clinical CT imaging.


2022 ◽  
Vol 17 (01) ◽  
pp. C01043
Author(s):  
L. Brombal ◽  
L. Rigon ◽  
F. Arfelli ◽  
R.H. Menk ◽  
F. Brun

Abstract The PEPI project is developing a new experimental facility integrating a chromatic photon-counting detector within an edge-illumination (EI) phase-contrast setup. In this context, a novel Geant4-based simulation tool has been introduced with the aim of defining the optimal design of the experimental setup. The code includes a custom X-ray refraction process and allows simulating the whole EI system, comprising a polychromatic and extended source, absorbing masks, substrates, their movement during acquisition, and X-ray detection. In this paper, a realistic spectral detector model is introduced and its energy response validated against experimental data acquired with synchrotron radiation at energies between 26 and 50 keV. Moreover, refraction and transmission images of a plastic phantom are reconstructed from simulation data and successfully compared with theoretical predictions. Finally, an optimization study aiming at finding the effect of the X-ray focal spot size (i.e. spatial coherence) on image quality is presented; the results suggest that, in the considered configuration, the system can tolerate source sizes up to 30 μm, while, for a fixed exposure time, the best signal-to-noise ratio in refraction images is found for source sizes in the order of 10 to 15 μm.


Sign in / Sign up

Export Citation Format

Share Document