internal heat capacity
Recently Published Documents


TOTAL DOCUMENTS

2
(FIVE YEARS 2)

H-INDEX

0
(FIVE YEARS 0)

2021 ◽  
pp. 45-61
Author(s):  
I. Antypov ◽  
◽  
A. Mishchenko ◽  
O. Shelimanova ◽  
S. Tarasenko ◽  
...  

When assessing the thermal condition of the building and the parameters of the microclimate of the premises, the main factors influencing its thermal inertia were identified and taken into account. An assessment of the influence of the resistance of enclosing structures on the efficiency of the heating system, taking into account the influence of external and internal climatic parameters in the dynamic mode. It is shown that the time factor and depth of regulation, as well as the outdoor air temperature are important factors. Researches are carried out and the expediency of introduction of a duty mode of heating of buildings of HIGH SCHOOLS is estimated. The given algorithm of control of process of heat release (especially in the presence of a point of "breaking" - average (them) on the schedule) in addition increases accuracy of the decisions of the specified problems and reduces a temperature deviation by 4 ÷ 6 ° C in comparison with usual ("linear") dependence that allows to correct more precisely release of the heat carrier in system of heating of a structure at introduction of a standby mode. It was found that it took about 6.5 hours to achieve normalized air temperature and space heating in the forced (after a long stay on duty). It is shown that the heat consumption of the system in such conditions of its operation compared to the nominal mode increased by 25 % (taking into account the limit value of the specific allowance from table H1 DBN B.2.5-67: 2013 "Heating, ventilation and air conditioning"), but for the entire period the action of the standby mode savings amounted to about 6-8% of energy consumed. Taking into account the design of the outer walls of the object of study, the temperature graph of the heating system was adjusted taking into account the value of the internal heat capacity of the building when implementing on-duty heating, which, according to preliminary estimates, will: improve comfort in the room; to reduce heating costs of the educational and administrative building of NULES of Ukraine by 10-12 % for the heating period. Key words: microclimate, internal heat capacity of a building, standby mode, heating system, heat loss


2021 ◽  
pp. 97-117
Author(s):  
I. Antypov ◽  
◽  
O. Shelimanova ◽  
S. Tarasenko ◽  
L. Martynyuk ◽  
...  

When assessing the thermal condition of the building and the parameters of the microclimate of the premises, the main factors influencing its thermal inertia were identified and taken into account. An assessment of the influence of the resistance of enclosing structures on the efficiency of the heating system, taking into account the influence of external and internal climatic parameters in the dynamic mode. It is shown that the time factor and depth of regulation, as well as the outdoor air temperature are important factors. Researches are carried out and the expediency of introduction of a duty mode of heating of buildings of HIGH SCHOOLS is estimated. The given algorithm of control of process of heat release (especially in the presence of a point of "breaking" - average (them) on the schedule) in addition increases accuracy of the decisions of the specified problems and reduces a temperature deviation by 4 ÷ 6 ° C in comparison with usual ("linear") dependence that allows to correct more precisely release of the heat carrier in system of heating of a structure at introduction of a standby mode. It was found that it took about 6.5 hours to achieve normalized air temperature and space heating in the forced (after a long stay on duty). It is shown that the heat consumption of the system in such conditions of its operation compared to the nominal mode increased by 25% (taking into account the limit value of the specific allowance from table H1 DBN B.2.5-67: 2013 "Heating, ventilation and air conditioning"), but for the entire period the action of the standby mode savings amounted to about 6-8% of energy consumed. Taking into account the design of the outer walls of the object of study, the temperature graph of the heating system was adjusted taking into account the value of the internal heat capacity of the building when implementing on-duty heating, which, according to preliminary estimates, will: improve comfort in the room; to reduce heating costs of the educational and administrative building of NULES of Ukraine by 10-12% for the heating period. Key words: enclosing structure, humidity conditions, dew point, partial pressure, water vapor


Sign in / Sign up

Export Citation Format

Share Document