Soil Resistivity Measurements and Ground Resistance

2021 ◽  
pp. 205-229

This chapter contains the factors affecting the soil resistivity and grounding resistance such as the soil moisture content, soil mineral content and soil temperature. It discusses the methods of measuring of soil resistivity and grounding resistance using Wenner method. Method to obtain the required samples for obtaining accurate site resistivity is presented. Soil resistivity measurement procedure is given in this chapter. The chapter contains three electrode method or fall-of-Potential method, dead earth method, and ground resistance testing existing systems using ‘Selective' Clamp-on-Measuring of high voltage transmission towers feet resistance. Methods of calculating the apparent soil resistivity of Multi-Layers, apparent soil resistivity of two layers and apparent soil resistivity of three layers are presented in this chapter.


2004 ◽  
Author(s):  
Vladimir Shevnin ◽  
Omar Delgado Rodríguez ◽  
Aleksandr Mousatov ◽  
Albert Ryjov

2015 ◽  
Vol 5 (2) ◽  
pp. 290-297 ◽  
Author(s):  
Md. Abdus SALAM ◽  
Quazi Mehbubar RAHMAN ◽  
Swee Peng ANG ◽  
Fushuan WEN

Author(s):  
I G. N. Janardana ◽  
W. Arta Wijaya ◽  
Cok Gede Indra Partha ◽  
N. Budiastra

Grounding system is one of the components in building equipment security. To fulfill the operational continuity of electronic equipment in Faculty of Engineering, Udayana University, Denpasar, a grounding system with a ground resistance of ? 3 ohms is required to be installed. The aim of this study is to find out the characteristics of grounding system to secure the equipment in the building around the research location, with ground resistance of ? 3 ohms and it is expected to be beneficial to use as a reference in grounding system installation as well as.  According to the measurement results at the research location, it is found that the soil resistance value is equal to 0.23 ohms, where the soil resistivity (?) is 28.89 Ohm-meters. There are some results analysis obtained in ground resistance value of ? 3 Ohm. Those are 1) grounding system type 1 rod where minimal depth installation of the electrode is 14 meters with ground resistance value of 2.6751 ohms; 2) grounding system type two rod with s < L, it is obtained that each depth is 8 meters with distance of 2 meters between electrodes, where the ground resistance value is 2.4940 ohms. In the installation of two electrodes with s > L, it is gained that the depth of each electrode is 6 meters where the distance between the electrodes is 8 meters and the ground resistance value is 2.8718 ohms. By applying the plates type grounding system with 3 meters in length, 1 meter in width, and 2 meters in installation depth is gained 2.8431 ohms ground resistance value. Furthermore, by applying grid type grounding system with 2 meters in length h = 2,5 meters in depth, A = 4 meters in width and the total length of the electrode diameter 1 cm is 504 meters, it is obtained 2.0978 ohms ground resistance value.


Sign in / Sign up

Export Citation Format