How does the laryngeal mask airway compare with bag-mask ventilation for neonatal resuscitation?

2018 ◽  
Author(s):  
Amanda Ullman
2017 ◽  
Vol 103 (3) ◽  
pp. F271-F276 ◽  
Author(s):  
Mark Brian Tracy ◽  
Archana Priyadarshi ◽  
Dimple Goel ◽  
Krista Lowe ◽  
Jacqueline Huvanandana ◽  
...  

BackgroundInternational neonatal resuscitation guidelines recommend the use of laryngeal mask airway (LMA) with newborn infants (≥34 weeks’ gestation or >2 kg weight) when bag-mask ventilation (BMV) or tracheal intubation is unsuccessful. Previous publications do not allow broad LMA device comparison.ObjectiveTo compare delivered ventilation of seven brands of size 1 LMA devices with two brands of face mask using self-inflating bag (SIB).Design40 experienced neonatal staff provided inflation cycles using SIB with positive end expiratory pressure (PEEP) (5 cmH2O) to a specialised newborn/infant training manikin randomised for each LMA and face mask. All subjects received prior education in LMA insertion and BMV.Results12 415 recorded inflations for LMAs and face masks were analysed. Leak detected was lowest with i-gel brand, with a mean of 5.7% compared with face mask (triangular 42.7, round 35.7) and other LMAs (45.5–65.4) (p<0.001). Peak inspiratory pressure was higher with i-gel, with a mean of 28.9 cmH2O compared with face mask (triangular 22.8, round 25.8) and other LMAs (14.3–22.0) (p<0.001). PEEP was higher with i-gel, with a mean of 5.1 cmH2O compared with face mask (triangular 3.0, round 3.6) and other LMAs (0.6–2.6) (p<0.001). In contrast to other LMAs examined, i-gel had no insertion failures and all users found i-gel easy to use.ConclusionThis study has shown dramatic performance differences in delivered ventilation, mask leak and ease of use among seven different brands of LMA tested in a manikin model. This coupled with no partial or complete insertion failures and ease of use suggests i-gel LMA may have an expanded role with newborn resuscitation as a primary resuscitation device.


2014 ◽  
Vol 21 (3) ◽  
pp. 189-194 ◽  
Author(s):  
Sebastian G. Russo ◽  
Christoph Stradtmann ◽  
Thomas A. Crozier ◽  
Christiane Ringer ◽  
Hans-Joachim Helms ◽  
...  

2015 ◽  
Vol 167 (2) ◽  
pp. 286-291.e1 ◽  
Author(s):  
Daniele Trevisanuto ◽  
Francesco Cavallin ◽  
Loi Ngoc Nguyen ◽  
Tien Viet Nguyen ◽  
Linh Dieu Tran ◽  
...  

Author(s):  
Joyce E O'Shea ◽  
Alexandra Scrivens ◽  
Gemma Edwards ◽  
Charles Christoph Roehr

This review examines the airway adjuncts currently used to acutely manage the neonatal airway. It describes the challenges encountered with facemask ventilation and intubation. Evidence is presented on how to optimise intubation safety and success rates with the use of videolaryngoscopy and attention to the intubation environment. The supraglottic airway (laryngeal mask airway) is emerging as a promising neonatal airway adjunct. It can be used effectively with little training to provide a viable alternative to facemask ventilation and intubation in neonatal resuscitation and be used as an alternative conduit for the administration of surfactant.


Sign in / Sign up

Export Citation Format

Share Document