How do different brands of size 1 laryngeal mask airway compare with face mask ventilation in a dedicated laryngeal mask airway teaching manikin?

2017 ◽  
Vol 103 (3) ◽  
pp. F271-F276 ◽  
Author(s):  
Mark Brian Tracy ◽  
Archana Priyadarshi ◽  
Dimple Goel ◽  
Krista Lowe ◽  
Jacqueline Huvanandana ◽  
...  

BackgroundInternational neonatal resuscitation guidelines recommend the use of laryngeal mask airway (LMA) with newborn infants (≥34 weeks’ gestation or >2 kg weight) when bag-mask ventilation (BMV) or tracheal intubation is unsuccessful. Previous publications do not allow broad LMA device comparison.ObjectiveTo compare delivered ventilation of seven brands of size 1 LMA devices with two brands of face mask using self-inflating bag (SIB).Design40 experienced neonatal staff provided inflation cycles using SIB with positive end expiratory pressure (PEEP) (5 cmH2O) to a specialised newborn/infant training manikin randomised for each LMA and face mask. All subjects received prior education in LMA insertion and BMV.Results12 415 recorded inflations for LMAs and face masks were analysed. Leak detected was lowest with i-gel brand, with a mean of 5.7% compared with face mask (triangular 42.7, round 35.7) and other LMAs (45.5–65.4) (p<0.001). Peak inspiratory pressure was higher with i-gel, with a mean of 28.9 cmH2O compared with face mask (triangular 22.8, round 25.8) and other LMAs (14.3–22.0) (p<0.001). PEEP was higher with i-gel, with a mean of 5.1 cmH2O compared with face mask (triangular 3.0, round 3.6) and other LMAs (0.6–2.6) (p<0.001). In contrast to other LMAs examined, i-gel had no insertion failures and all users found i-gel easy to use.ConclusionThis study has shown dramatic performance differences in delivered ventilation, mask leak and ease of use among seven different brands of LMA tested in a manikin model. This coupled with no partial or complete insertion failures and ease of use suggests i-gel LMA may have an expanded role with newborn resuscitation as a primary resuscitation device.

2015 ◽  
Vol 167 (2) ◽  
pp. 286-291.e1 ◽  
Author(s):  
Daniele Trevisanuto ◽  
Francesco Cavallin ◽  
Loi Ngoc Nguyen ◽  
Tien Viet Nguyen ◽  
Linh Dieu Tran ◽  
...  

2014 ◽  
Vol 21 (3) ◽  
pp. 189-194 ◽  
Author(s):  
Sebastian G. Russo ◽  
Christoph Stradtmann ◽  
Thomas A. Crozier ◽  
Christiane Ringer ◽  
Hans-Joachim Helms ◽  
...  

2017 ◽  
Vol 103 (3) ◽  
pp. 255-260 ◽  
Author(s):  
Nicolas J Pejovic ◽  
Daniele Trevisanuto ◽  
Clare Lubulwa ◽  
Susanna Myrnerts Höök ◽  
Francesco Cavallin ◽  
...  

ObjectiveMortality rates from birth asphyxia in low-income countries remain high. Face mask ventilation (FMV) performed by midwives is the usual method of resuscitating neonates in such settings but may not always be effective. The i-gel is a cuffless laryngeal mask airway (LMA) that could enhance neonatal resuscitation performance. We aimed to compare LMA and face mask (FM) during neonatal resuscitation in a low-resource setting.SettingMulago National Referral Hospital, Kampala, Uganda.DesignThis prospective randomised clinical trial was conducted at the labour ward operating theatre. After a brief training on LMA and FM use, infants with a birth weight >2000 g and requiring positive pressure ventilation at birth were randomised to resuscitation by LMA or FM. Resuscitations were video recorded.Main outcome measuresTime to spontaneous breathing.ResultsForty-nine (24 in the LMA and 25 in the FM arm) out of 50 enrolled patients were analysed. Baseline characteristics were comparable between the two arms. Time to spontaneous breathing was shorter in LMA arm than in FM arm (mean 153 s (SD±59) vs 216 s (SD±92)). All resuscitations were effective in LMA arm, whereas 11 patients receiving FM were converted to LMA because response to FMV was unsatisfactory. There were no adverse effects.ConclusionA cuffless LMA was more effective than FM in reducing time to spontaneous breathing. LMA seems to be safe and effective in clinical practice after a short training programme. Its potential benefits on long-term outcomes need to be assessed in a larger trial.Clinical trial registryThis trial was registered in https://clinicaltrials.gov, with registration number NCT02042118.


Neonatology ◽  
2021 ◽  
pp. 1-13
Author(s):  
Marlies Bruckner ◽  
Gianluca Lista ◽  
Ola D. Saugstad ◽  
Georg M. Schmölzer

Approximately 800,000 newborns die annually due to birth asphyxia. The resuscitation of asphyxiated term newly born infants often occurs unexpected and is challenging for healthcare providers as it demands experience and knowledge in neonatal resuscitation. Current neonatal resuscitation guidelines often focus on resuscitation of extremely and/or very preterm infants; however, the recommendations for asphyxiated term newborn infants differ in some aspects to those for preterm infants (i.e., respiratory support, supplemental oxygen, and temperature management). Since the update of the neonatal resuscitation guidelines in 2015, several studies examining various resuscitation approaches to improve the outcome of asphyxiated infants have been published. In this review, we discuss current recommendations and recent findings and provide an overview of delivery room management of asphyxiated term newborn infants.