Flow-injection potentiometric determination of creatinine in urine using sub-Nernstian linear response range

1993 ◽  
Vol 5 (2) ◽  
pp. 113-120 ◽  
Author(s):  
Wojciech Matuszewski ◽  
Marek Trojanowicz ◽  
Mark E. Meyerhoff ◽  
Anna Moszczyńska ◽  
Elzbieta Lange-Moroz
2012 ◽  
Vol 600 ◽  
pp. 230-233 ◽  
Author(s):  
Qiu Huan Han ◽  
Jian Fei Xia ◽  
Zong Hua Wang ◽  
Yan Zhi Xia ◽  
Fei Fei Zhang

A new type of poly (sulfosalicylic acid)/graphene modified electrode (PSA/GH/GCE) was fabricated by dispensing graphene (GH) on glassy carbon electrode (GCE) and then electro-polymerized sulfosalicylic acid onto GH/GCE with cyclic voltammtry method. It can be used with composite properties of biochemical materials for highly selective and sensitive detection of dopamine (DA) even in the presence of mass ascorbic acid (AA). The linear response range for DA was 70 nM to 700 μM, and the detection limit was 20 nM (S/N = 3).


2012 ◽  
Vol 2012 ◽  
pp. 1-6 ◽  
Author(s):  
Frantisek Cacho ◽  
Lukas Lauko ◽  
Alena Manova ◽  
Jan Dzurov ◽  
Ernest Beinrohr

Flow-through stripping chronopotentiometry with a gold wire electrode was used for the determination of total arsenic and cadmium in cadmium sulphate solutions for cadmium production. The analysis is based on the online separation of arsenic as arsenate anion from cadmium cations by means of a cation exchanger. On measuring arsenate in the effluent, the trapped cadmium is eluted by sodium chloride solution and determined in a small segment of the effluent by making use of the same electrode. The elaborated protocol enables a full automatic measurement of both species in the same sample solution. The accuracy of the results was confirmed by atomic absorption spectrometry. The LOD and LOQ for Arsenic were found to be 0.9 μg dm-3and 2.7 μg dm-3, respectively. A linear response range was observed in the concentration range of 1 to 300 μg dm-3for sample volumes of 4 mL. The repeatability and reproducibility were found to be 2.9% and 5.2%, respectively. The linear response range for cadmium was found to be 0.5 to 60 g/L. The method was tested on samples from a cadmium production plant.


2020 ◽  
Vol 12 (49) ◽  
pp. 55362-55371
Author(s):  
Tingting Zhao ◽  
Li Yuan ◽  
Tongkuai Li ◽  
Longlong Chen ◽  
Xifeng Li ◽  
...  

2004 ◽  
Vol 78 (2) ◽  
pp. 107-113 ◽  
Author(s):  
R.M. El-Nashar ◽  
N.T. Abdel Ghani ◽  
A.A. Bioumy

Talanta ◽  
1989 ◽  
Vol 36 (8) ◽  
pp. 811-815 ◽  
Author(s):  
T.Krawczyński vel Krawczyk ◽  
B. Szostek ◽  
M. Trojanowicz

Sign in / Sign up

Export Citation Format

Share Document