scholarly journals Successful Identification of Anatomical Markers and Placement of Feeding Tubes in Critically Ill Patients via Camera‐Assisted Technology with Real‐Time Video Guidance

2018 ◽  
Vol 43 (1) ◽  
pp. 118-125 ◽  
Author(s):  
Paul E. Wischmeyer ◽  
Michelle M. McMoon ◽  
Nathan H. Waldron ◽  
Elizabeth J. Dye
2005 ◽  
Vol 33 (2) ◽  
pp. 229-234 ◽  
Author(s):  
R. J. Young ◽  
M. J. Chapman ◽  
R. Fraser ◽  
R. Vozzo ◽  
D. P. Chorley ◽  
...  

Delivery of enteral nutrition in critically ill patients is often hampered by gastric stasis necessitating direct feeding into the small intestine. Current techniques for placement of post-pyloric feeding catheters are complex, time consuming or both, and improvements in feeding tube placement techniques are required. The Cathlocator™ is a novel device that permits real time localisation of the end of feeding tubes via detection of a magnetic field generated by a small electric current in a coil incorporated in the tip of the tube. We performed a pilot study evaluating the feasibility of the Cathlocator™ system to guide and evaluate the placement of (1) nasoduodenal feeding tubes, and (2) nasogastric drainage tubes in critically ill patients with feed intolerance due to slow gastric emptying. A prospective study of eight critically ill patients was undertaken in the intensive care unit of a tertiary hospital. The Cathlocator™ was used to (1) guide the positioning of the tubes post-pylorically and (2) determine whether nasogastric and nasoduodenal tubes were placed correctly. Tube tip position was compared with data obtained by radiology. Data are expressed as median (range). Duodenal tube placement was successful in 7 of 8 patients (insertion time 12.6 min (5.3–34.4)). All nasogastric tube placements were successful (insertion time 3.4 min (0.6–10.0)). The Cathlocator™ accurately determined the position of both tubes without complication in all cases. The Cathlocator™ allows placement and location of an enteral feeding tube in real time in critically ill patients with slow gastric emptying. These findings warrant further studies into the application of this technique for placement of post-pyloric feeding tubes.


2020 ◽  
Vol 44 (8) ◽  
pp. 1484-1491 ◽  
Author(s):  
Liam McKeever ◽  
Sarah J. Peterson ◽  
Sofia Cienfuegos ◽  
Jaime Rizzie ◽  
Omar Lateef ◽  
...  

2002 ◽  
Vol 28 (12) ◽  
pp. 1768-1774 ◽  
Author(s):  
Mette Berger ◽  
Marc Bollmann ◽  
Jean-Pierre Revelly ◽  
M.-Christine Cayeux ◽  
Nathalie Pilon ◽  
...  

2008 ◽  
Vol 17 (1) ◽  
pp. 53-61 ◽  
Author(s):  
Debra O’Meara ◽  
Eduardo Mireles-Cabodevila ◽  
Fran Frame ◽  
A. Christine Hummell ◽  
Jeffrey Hammel ◽  
...  

Background Published reports consistently describe incomplete delivery of prescribed enteral nutrition. Which specific step in the process delays or interferes with the administration of a full dose of nutrients is unclear. Objectives To assess factors associated with interruptions in enteral nutrition in critically ill patients receiving mechanical ventilation. Methods An observational prospective study of 59 consecutive patients who required mechanical ventilation and were receiving enteral nutrition was done in an 18-bed medical intensive care unit of an academic center. Data were collected prospectively on standardized forms. Steps involved in the feeding process from admission to discharge were recorded, each step was timed, and delivery of nutrition was quantified. Results Patients received approximately 50% (mean, 1106.3; SD, 885.9 Cal) of the prescribed caloric needs. Enteral nutrition was interrupted 27.3% of the available time. A mean of 1.13 interruptions occurred per patient per day; enteral nutrition was interrupted a mean of 6 (SD, 0.9) hours per patient each day. Prolonged interruptions were mainly associated with problems related to small-bore feeding tubes (25.5%), increased residual volumes (13.3%), weaning (11.7%), and other reasons (22.8%). Placement and confirmation of placement of the small-bore feeding tube were significant causes of incomplete delivery of nutrients on the day of admission. Conclusions Delivery of enteral nutrition in critically ill patients receiving mechanical ventilation is interrupted by practices embedded in the care of these patients. Evaluation of the process reveals areas to improve the delivery of enteral nutrition.


2010 ◽  
Vol 30 (6) ◽  
pp. 80-82 ◽  
Author(s):  
Carol M. McGinnis ◽  
Pat Worthington ◽  
Linda M. Lord

Nutrition ◽  
2000 ◽  
Vol 16 (4) ◽  
pp. 264-267 ◽  
Author(s):  
Guillermo Huerta ◽  
Vinod K Puri

Sign in / Sign up

Export Citation Format

Share Document