scholarly journals Systematic Regularization of Linear Inverse Solutions of the EEG Source Localization Problem

NeuroImage ◽  
2002 ◽  
Vol 17 (1) ◽  
pp. 287-301 ◽  
Author(s):  
Christophe Phillips ◽  
Michael D. Rugg ◽  
Karl J. Friston
2018 ◽  
Vol 65 (6) ◽  
pp. 1359-1372 ◽  
Author(s):  
Elvira Pirondini ◽  
Behtash Babadi ◽  
Gabriel Obregon-Henao ◽  
Camilo Lamus ◽  
Wasim Q. Malik ◽  
...  

2016 ◽  
Author(s):  
Keyvan Mahjoory ◽  
Vadim V. Nikulin ◽  
Loïc Botrel ◽  
Klaus Linkenkaer-Hansen ◽  
Marco M. Fato ◽  
...  

AbstractAs the EEG inverse problem does not have a unique solution, the sources reconstructed from EEG and their connectivity properties depend on forward and inverse modeling parameters such as the choice of an anatomical template and electrical model, prior assumptions on the sources, and further implementational details. In order to use source connectivity analysis as a reliable research tool, there is a need for stability across a wider range of standard estimation routines. Using resting state EEG recordings of N=65 participants acquired within two studies, we present the first comprehensive assessment of the consistency of EEG source localization and functional/effective connectivity metrics across two anatomical templates (ICBM152 and Colin27), three electrical models (BEM, FEM and spherical harmonics expansions), three inverse methods (WMNE, eLORETA and LCMV), and three software implementations (Brainstorm, Fieldtrip and our own toolbox). Source localizations were found to be more stable across reconstruction pipelines than subsequent estimations of functional connectivity, while effective connectivity estimates where the least consistent. All results were relatively unaffected by the choice of the electrical head model, while the choice of the inverse method and source imaging package induced a considerable variability. In particular, a relatively strong difference was found between LCMV beamformer solutions on one hand and eLORETA/WMNE distributed inverse solutions on the other hand. We also observed a gradual decrease of consistency when results are compared between studies, within individual participants, and between individual participants. In order to provide reliable findings in the face of the observed variability, additional simulations involving interacting brain sources are required. Meanwhile, we encourage verification of the obtained results using more than one source imaging procedure.


2008 ◽  
Vol 19 (3) ◽  
pp. 1397-1416 ◽  
Author(s):  
Amir Beck ◽  
Marc Teboulle ◽  
Zahar Chikishev

2014 ◽  
Vol 28 (4) ◽  
pp. 499-514 ◽  
Author(s):  
Qaiser Mahmood ◽  
Artur Chodorowski ◽  
Andrew Mehnert ◽  
Johanna Gellermann ◽  
Mikael Persson

Author(s):  
E. Cuartas-Morales ◽  
Angel Torrado-Carvajal ◽  
Juan Antonio Hernandez-Tamames ◽  
Norberto Malpica ◽  
G. Castellanos-Dominguez

Sign in / Sign up

Export Citation Format

Share Document