Lung Nodule Detection Using Combined Traditional and Deep Models and Chest CT

Author(s):  
Junjie Zhang ◽  
Zhaowei Huang ◽  
Tairan Huang ◽  
Yong Xia ◽  
Yanning Zhang
2021 ◽  
Author(s):  
Pasquale Ardimento ◽  
Lerina Aversano ◽  
Mario Luca Bernardi ◽  
Marta Cimitile

2021 ◽  
Vol 2021 ◽  
pp. 1-10
Author(s):  
Fukui Liang ◽  
Caiqin Li ◽  
Xiaoqin Fu

Lung cancer is one of the most malignant tumors. If it can be detected early and treated actively, it can effectively improve a patient’s survival rate. Therefore, early diagnosis of lung cancer is very important. Early-stage lung cancer usually appears as a solitary lung nodule on medical imaging. It usually appears as a round or nearly round dense shadow in the chest radiograph. It is difficult to distinguish lung nodules and lung soft tissues with the naked eye. Therefore, this article proposes a deep learning-based artificial intelligence chest CT lung nodule detection performance evaluation study, aiming to evaluate the value of chest CT imaging technology in the detection of noncalcified nodules and provide help for the detection and treatment of lung cancer. In this article, the Lung Medical Imaging Database Consortium (LIDC) was selected to obtain 536 usable cases based on inclusion criteria; 80 cases were selected for examination, artificial intelligence software, radiologists, and thoracic imaging specialists. Using 80 pulmonary nodules detection in each case, the pathological type of pulmonary nodules, nonlime tuberculous test results, detection sensitivity, false negative rate, false positive rate, and CT findings were individually analyzed, and the detection efficiency software of artificial intelligence was evaluated. Experiments have proved that the sensitivity of artificial intelligence software to detect noncalcified nodules in the pleural, peripheral, central, and hilar areas is higher than that of radiologists, indicating that the method proposed in this article has achieved good detection results. It has a better nodule detection sensitivity than a radiologist, reducing the complexity of the detection process.


Author(s):  
Yaping Zhang ◽  
Beibei Jiang ◽  
Lu Zhang ◽  
Marcel J.W. Greuter ◽  
Geertruida H. de Bock ◽  
...  

Background: Artificial intelligence (AI)-based automatic lung nodule detection system improves the detection rate of nodules. It is important to evaluate the clinical value of AI system by comparing AI-assisted nodule detection with actu-al radiology reports. Objective: To compare the detection rate of lung nodules between the actual radiology reports and AI-assisted reading in lung cancer CT screening. Methods: Participants in chest CT screening from November to December 2019 were retrospectively included. In the real-world radiologist observation, 14 residents and 15 radiologists participated to finalize radiology reports. In AI-assisted reading, one resident and one radiologist reevaluated all subjects with the assistance of an AI system to lo-cate and measure the detected lung nodules. A reading panel determined the type and number of detected lung nodules between these two methods. Results: In 860 participants (57±7 years), the reading panel confirmed 250 patients with >1 solid nodule, while radiolo-gists observed 131, lower than 247 by AI-assisted reading (p<0.001). The panel confirmed 111 patients with >1 non-solid nodule, whereas radiologist observation identified 28, lower than 110 by AI-assisted reading (p<0.001). The accuracy and sensitivity of radiologist observation for solid nodules were 86.2% and 52.4%, lower than 99.1% and 98.8% by AI-assisted reading, respectively. These metrics were 90.4% and 25.2% for non-solid nodules, lower than 98.8% and 99.1% by AI-assisted reading, respectively. Conclusion: Comparing with the actual radiology reports, AI-assisted reading greatly improves the accuracy and sensi-tivity of nodule detection in chest CT, which benefits lung nodule detection, especially for non-solid nodules.


2011 ◽  
Vol 38 (5) ◽  
pp. 2609-2618 ◽  
Author(s):  
Xiang Li ◽  
Ehsan Samei ◽  
Huiman X. Barnhart ◽  
Ana Maria Gaca ◽  
Caroline L. Hollingsworth ◽  
...  

Radiology ◽  
2003 ◽  
Vol 228 (1) ◽  
pp. 70-75 ◽  
Author(s):  
Jane P. Ko ◽  
Henry Rusinek ◽  
David P. Naidich ◽  
Georgeann McGuinness ◽  
Ami N. Rubinowitz ◽  
...  

2005 ◽  
Vol 6 (2) ◽  
pp. 89 ◽  
Author(s):  
In Jae Lee ◽  
Gordon Gamsu ◽  
Julianna Czum ◽  
Ning Wu ◽  
Rebecca Johnson ◽  
...  

Diagnostics ◽  
2021 ◽  
Vol 12 (1) ◽  
pp. 93
Author(s):  
Yu-Sen Huang ◽  
Emi Niisato ◽  
Mao-Yuan Marine Su ◽  
Thomas Benkert ◽  
Ning Chien ◽  
...  

This prospective study aimed to investigate the ability of spiral ultrashort echo time (UTE) and compressed sensing volumetric interpolated breath-hold examination (CS-VIBE) sequences in magnetic resonance imaging (MRI) compared to conventional VIBE and chest computed tomography (CT) in terms of image quality and small nodule detection. Patients with small lung nodules scheduled for video-assisted thoracoscopic surgery (VATS) for lung wedge resection were prospectively enrolled. Each patient underwent non-contrast chest CT and non-contrast MRI on the same day prior to thoracic surgery. The chest CT was performed to obtain a standard reference for nodule size, location, and morphology. The chest MRI included breath-hold conventional VIBE and CS-VIBE with scanning durations of 11 and 13 s, respectively, and free-breathing spiral UTE for 3.5–5 min. The signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and normal structure visualizations were measured to evaluate MRI quality. Nodule detection sensitivity was evaluated on a lobe-by-lobe basis. Inter-reader and inter-modality reliability analyses were performed using the Cohen κ statistic and the nodule size comparison was performed using Bland–Altman plots. Among 96 pulmonary nodules requiring surgery, the average nodule diameter was 7.7 ± 3.9 mm (range: 4–20 mm); of the 73 resected nodules, most were invasive cancer (74%) or pre-invasive carcinoma in situ (15%). Both spiral UTE and CS-VIBE images achieved significantly higher overall image quality scores, SNRs, and CNRs than conventional VIBE. Spiral UTE (81%) and CS-VIBE (83%) achieved a higher lung nodule detection rate than conventional VIBE (53%). Specifically, the nodule detection rate for spiral UTE and CS-VIBE reached 95% and 100% for nodules >8 and >10 mm, respectively. A 90% detection rate was achieved for nodules of all sizes with a part-solid or solid morphology. Spiral UTE and CS-VIBE under-estimated the nodule size by 0.2 ± 1.4 mm with 95% limits of agreement from −2.6 to 2.9 mm and by 0.2 ± 1.7 mm with 95% limits of agreement from −3.3 to 3.5 mm, respectively, compared to the reference CT. In conclusion, chest CT remains the gold standard for lung nodule detection due to its high image resolutions. Both spiral UTE and CS-VIBE MRI could detect small lung nodules requiring surgery and could be considered a potential alternative to chest CT; however, their clinical application requires further investigation.


2008 ◽  
Vol 64 (3) ◽  
pp. 316-324 ◽  
Author(s):  
Megumi Yamamoto ◽  
Ikuo Kawashita ◽  
Yasuhiko Okura ◽  
Mitoshi Akiyama ◽  
Koichi Fujikawa ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document