ultrashort echo time
Recently Published Documents


TOTAL DOCUMENTS

341
(FIVE YEARS 135)

H-INDEX

35
(FIVE YEARS 9)

Diagnostics ◽  
2021 ◽  
Vol 12 (1) ◽  
pp. 93
Author(s):  
Yu-Sen Huang ◽  
Emi Niisato ◽  
Mao-Yuan Marine Su ◽  
Thomas Benkert ◽  
Ning Chien ◽  
...  

This prospective study aimed to investigate the ability of spiral ultrashort echo time (UTE) and compressed sensing volumetric interpolated breath-hold examination (CS-VIBE) sequences in magnetic resonance imaging (MRI) compared to conventional VIBE and chest computed tomography (CT) in terms of image quality and small nodule detection. Patients with small lung nodules scheduled for video-assisted thoracoscopic surgery (VATS) for lung wedge resection were prospectively enrolled. Each patient underwent non-contrast chest CT and non-contrast MRI on the same day prior to thoracic surgery. The chest CT was performed to obtain a standard reference for nodule size, location, and morphology. The chest MRI included breath-hold conventional VIBE and CS-VIBE with scanning durations of 11 and 13 s, respectively, and free-breathing spiral UTE for 3.5–5 min. The signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and normal structure visualizations were measured to evaluate MRI quality. Nodule detection sensitivity was evaluated on a lobe-by-lobe basis. Inter-reader and inter-modality reliability analyses were performed using the Cohen κ statistic and the nodule size comparison was performed using Bland–Altman plots. Among 96 pulmonary nodules requiring surgery, the average nodule diameter was 7.7 ± 3.9 mm (range: 4–20 mm); of the 73 resected nodules, most were invasive cancer (74%) or pre-invasive carcinoma in situ (15%). Both spiral UTE and CS-VIBE images achieved significantly higher overall image quality scores, SNRs, and CNRs than conventional VIBE. Spiral UTE (81%) and CS-VIBE (83%) achieved a higher lung nodule detection rate than conventional VIBE (53%). Specifically, the nodule detection rate for spiral UTE and CS-VIBE reached 95% and 100% for nodules >8 and >10 mm, respectively. A 90% detection rate was achieved for nodules of all sizes with a part-solid or solid morphology. Spiral UTE and CS-VIBE under-estimated the nodule size by 0.2 ± 1.4 mm with 95% limits of agreement from −2.6 to 2.9 mm and by 0.2 ± 1.7 mm with 95% limits of agreement from −3.3 to 3.5 mm, respectively, compared to the reference CT. In conclusion, chest CT remains the gold standard for lung nodule detection due to its high image resolutions. Both spiral UTE and CS-VIBE MRI could detect small lung nodules requiring surgery and could be considered a potential alternative to chest CT; however, their clinical application requires further investigation.


Radiology ◽  
2021 ◽  
Author(s):  
Yoshiharu Ohno ◽  
Daisuke Takenaka ◽  
Takeshi Yoshikawa ◽  
Masao Yui ◽  
Hisanobu Koyama ◽  
...  

2021 ◽  
Vol 12 (1) ◽  
Author(s):  
Susann-Cathrin Olthof ◽  
Christian Reinert ◽  
Konstantin Nikolaou ◽  
Christina Pfannenberg ◽  
Sergios Gatidis ◽  
...  

Abstract Background Detection of pulmonary nodules in MRI requires fast imaging strategies without respiratory motion impairment, such as single-breath-hold Cartesian VIBE. As patients with pulmonary diseases have limited breath-hold capacities, this study investigates the clinical feasibility of non-Cartesian Spiral VIBE under free-breathing compared to CT as the gold standard. Methods Prospective analysis of 27 oncological patients examined in PET/CT and PET/MR. A novel motion-robust 3D ultrashort-echo-time (UTE) MR sequence was evaluated in comparison with CT and conventional breath-hold MR. CT scans were performed under breath-hold in end-expiratory and end-inspiratory position (CT ex, CT in). MR data was acquired with non-contrast-enhanced breath-hold Cartesian VIBE followed by a free-breathing 3D UTE Spiral VIBE. Impact of respiratory motion on pulmonary evaluation was investigated by two readers in Cartesian VIBE, followed by UTE Spiral VIBE and CT ex and the reference standard of CT in. Diagnostic accuracy was calculated, and visual image quality assessed. Results Higher detection rate and sensitivity of pulmonary nodules in free-breathing UTE Spiral VIBE in comparison with breath-hold Cartesian VIBE were found for lesions > 10 mm (UTE Spiral VIBE/VIBE/CT ex): 93%/54%/100%; Lesions 5–10 mm: 67%/25%/ 92%; Lesions < 5 mm: 11%/11%/78%. Lobe-based analysis revealed sensitivities and specificities of 64%/96%/41% and 96%/93%/100% for UTE Spiral VIBE/VIBE/CT ex. Conclusion Free-breathing UTE Spiral VIBE indicates higher sensitivity for detection of pulmonary nodules than breath-hold Cartesian VIBE and is a promising but time-consuming approach. However, sensitivity and specificity of inspiratory CT remain superior in comparison and should be preferred for detection of pulmonary lesions.


2021 ◽  
Vol 29 (4) ◽  
pp. 583-593
Author(s):  
Naoharu Kobayashi ◽  
Sven Bambach ◽  
Mai-Lan Ho

Author(s):  
Corona Metz ◽  
David Böckle ◽  
Julius Frederik Heidenreich ◽  
Andreas Max Weng ◽  
Thomas Benkert ◽  
...  

Purpose To evaluate the feasibility of non-contrast-enhanced three-dimensional ultrashort echo time (3D-UTE) MRI for pulmonary imaging in immunocompromised patients during hematopoietic stem cell transplantation (HSCT). Methods MRI was performed using a stack-of-spirals 3D-UTE sequence (slice thickness: 2.34mm; matrix: 256 × 256; acquisition time: 12.7–17.6 seconds) enabling imaging of the entire thorax within single breath-holds. Patients underwent MRI before HSCT initiation, in the case of periprocedural pneumonia, before discharge, and in the case of re-hospitalization. Two readers separately assessed the images regarding presence of pleural effusions, ground glass opacities (GGO), and consolidations on a per lung basis. A T2-weighted (T2w) multi-shot Turbo Spin Echo sequence (BLADE) was acquired in coronal orientation during breath-hold (slice thickness: 6.00mm; matrix: 320 × 320; acquisition time: 3.1–5.5 min) and read on a per lesion basis. Low-dose CT scans in inspiration were used as reference and were read on a per lung basis. Only scans performed within a maximum of three days were included in the inter-method analyses. Interrater agreement, sensitivity, specificity, positive and negative predictive values, and diagnostic accuracy of 3D-UTE MRI were calculated. Results 67 MRI scans of 28 patients were acquired. A reference CT examination was available for 33 scans of 23 patients. 3D-UTE MRI showed high sensitivity and specificity regarding pleural effusions (n = 6; sensitivity, 92 %; specificity, 100 %) and consolidations (n = 22; sensitivity 98 %, specificity, 86 %). Diagnostic performance was lower for GGO (n = 9; sensitivity, 63 %; specificity, 84 %). Accuracy rates were high (pleural effusions, 98 %; GGO, 79 %; consolidations 94 %). Interrater agreement was substantial for consolidations and pleural effusions (κ = 0.69–0.82) and moderate for GGO (κ = 0.54). Compared to T2w imaging, 3D-UTE MRI depicted the assessed pathologies with at least equivalent quality and was rated superior regarding consolidations and GGO in ~50 %. Conclusion Non-contrast 3D-UTE MRI enables radiation-free assessment of typical pulmonary complications during HSCT procedure within a single breath-hold. Yet, CT was found to be superior regarding the identification of pure GGO changes. Key Points:  Citation Format


Sign in / Sign up

Export Citation Format

Share Document