Space Edge Detection Based SVM Algorithm

Author(s):  
Fanrong Meng ◽  
Wei Lin ◽  
Zhixiao Wang
Keyword(s):  
2021 ◽  
Vol 2021 ◽  
pp. 1-11
Author(s):  
Zhongyi Li ◽  
Xi Ji

Background. Wrist joint injury refers to the injury of the wrist joint caused by excessive stretching of the ligaments and joint capsules around the joint caused by indirect violence. The tissue structure of the wrist joint is complex, and the clinical diagnosis effect is poor. Methods. The purpose of this study was to improve the diagnostic accuracy of wrist joint injuries and provide evidence for imaging analysis and automatic diagnosis of lesions in patients with wrist joint injuries. The Canny algorithm was adopted to extract the edge features of the patient’s magnetic resonance imaging (MRI) image, and the particle swarm optimization-support vector machine (PSO-SVM) algorithm was applied to segment the lesion. The image processing effect of the algorithm was evaluated by taking peak signal to noise ratio (PSNR), mean square error (MSE), figure of merit (FOM), and structural similarity (SSIM) as indicators. The accuracy, sensitivity, specificity, and Dice similarity coefficient of the algorithm were analyzed to evaluate the diagnostic accuracy in WJI. Results. Compared with the Gradient Vector Flo (GVF) algorithm and the Elastic Automatic Region Growing (ERG) algorithm, the edge stability of the PSO-SVM algorithm was stable above 0.9. After the quality of images processed using different algorithms was analyzed, it was found that the PSNR of the PSO-SVM algorithm was 26.891 ± 5.331 dB, the MSE was 0.0014 ± 0.0003, the FOM was 0.8832 ± 0.0957, and the SSIM was 0.9032 ± 0.0807. The four indicators were all much better than those of the GVF algorithm and the EARG algorithm, showing statistically obvious differences ( P  < 0.05). Analysis on diagnostic accuracy of different algorithms for WJI suggested that the diagnostic accuracy of the PSO-SVM algorithm was 0.9413, the sensitivity was 0.9129, the specificity was 0.9088, and the Dice similarity coefficient was 0.8715. The four indicators all showed statistically great difference compared with those of the GVF algorithm and the EARG algorithm ( P  < 0.05). Conclusions. The PSO-SVM algorithm showed excellent edge detection performance and higher accuracy in the diagnosis of WJI, which can assist clinicians in the clinical auxiliary diagnosis of WJI.


Author(s):  
Michael K. Kundmann ◽  
Ondrej L. Krivanek

Parallel detection has greatly improved the elemental detection sensitivities attainable with EELS. An important element of this advance has been the development of differencing techniques which circumvent limitations imposed by the channel-to-channel gain variation of parallel detectors. The gain variation problem is particularly severe for detection of the subtle post-threshold structure comprising the EXELFS signal. Although correction techniques such as gain averaging or normalization can yield useful EXELFS signals, these are not ideal solutions. The former is a partial throwback to serial detection and the latter can only achieve partial correction because of detector cell inhomogeneities. We consider here the feasibility of using the difference method to efficiently and accurately measure the EXELFS signal.An important distinction between the edge-detection and EXELFS cases lies in the energy-space periodicities which comprise the two signals. Edge detection involves the near-edge structure and its well-defined, shortperiod (5-10 eV) oscillations. On the other hand, EXELFS has continuously changing long-period oscillations (∼10-100 eV).


2008 ◽  
Vol 128 (7) ◽  
pp. 1185-1190 ◽  
Author(s):  
Kuniaki Fujimoto ◽  
Hirofumi Sasaki ◽  
Mitsutoshi Yahara
Keyword(s):  

2014 ◽  
Vol 9 (5) ◽  
pp. 1060
Author(s):  
Frank Zoko Ble ◽  
Matti Lehtonen ◽  
Ari Sihvola ◽  
Charles Kim

2017 ◽  
Author(s):  
Prof. S. H. Jawale ◽  
Prof. A. B. Bavaskar
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document