Cyclic Loading Test on 0.2-Scale RC Column Models Repaired by Strain-Hardening Fiber-Reinforced Cement-Based Composites

Author(s):  
Shogo Yamamoto ◽  
Yoshitomo Yano ◽  
Koji Kinoshita ◽  
Seungchan Lim ◽  
Kazuhide Shinya
2012 ◽  
Vol 36 ◽  
pp. 325-336 ◽  
Author(s):  
Hong-Gun Park ◽  
Hyeon-Jong Hwang ◽  
Cheol-Ho Lee ◽  
Chang-Hee Park ◽  
Chang-Nam Lee

2019 ◽  
Vol 345 ◽  
pp. 1-14 ◽  
Author(s):  
Yidong Xia ◽  
Zhengshou Lai ◽  
Tyler Westover ◽  
Jordan Klinger ◽  
Hai Huang ◽  
...  

2020 ◽  
Vol 9 (12) ◽  
pp. 840-847
Author(s):  
Shaobo Nie ◽  
Ming Li ◽  
Hui Ji ◽  
Zhirui Li ◽  
Wenwen Li ◽  
...  

Aims Restoration of proximal medial femoral support is the keystone in the treatment of intertrochanteric fractures. None of the available implants are effective in constructing the medial femoral support. Medial sustainable nail (MSN-II) is a novel cephalomedullary nail designed for this. In this study, biomechanical difference between MSN-II and proximal femoral nail anti-rotation (PFNA-II) was compared to determine whether or not MSN-II can effectively reconstruct the medial femoral support. Methods A total of 36 synthetic femur models with simulated intertrochanteric fractures without medial support (AO/OTA 31-A2.3) were assigned to two groups with 18 specimens each for stabilization with MSN-II or PFNA-II. Each group was further divided into three subgroups of six specimens according to different experimental conditions respectively as follows: axial loading test; static torsional test; and cyclic loading test. Results The mean axial stiffness, vertical displacement, and maximum failure load of MSN-II were 258.47 N/mm (SD 42.27), 2.99 mm (SD 0.56), and 4,886 N (SD 525.31), respectively, while those of PFNA-II were 170.28 N/mm (SD 64.63), 4.86 mm (SD 1.66), and 3,870.87 N (SD 552.21), respectively. The mean torsional stiffness and failure torque of MSN-II were 1.72 N m/° (SD 0.61) and 16.54 N m (SD 7.06), respectively, while those of PFNA-II were 0.61 N m/° (SD 0.39) and 6.6 N m (SD 6.65), respectively. The displacement of MSN-II in each cycle point was less than that of PFNA-II in cyclic loading test. Significantly higher stiffness and less displacement were detected in the MSN-II group (p < 0.05). Conclusion The biomechanical performance of MSN-II was better than that of PFNA-II, suggesting that MSN-II may provide more effective mechanical support in the treatment of unstable intertrochanteric fractures. Cite this article: Bone Joint Res 2020;9(12):840–847.


Sign in / Sign up

Export Citation Format

Share Document