A new fiber optic physico-chemical sensor for chlorinated hydrocarbons in water

1992 ◽  
Vol 342 (1-2) ◽  
pp. 202-202 ◽  
Author(s):  
R. Krska ◽  
K. Taga ◽  
R. Kellner ◽  
A. Messica ◽  
A. Katzir
1993 ◽  
Vol 47 (9) ◽  
pp. 1484-1487 ◽  
Author(s):  
R. Krska ◽  
K. Taga ◽  
R. Kellner

In this work the development and validation of a new MIR fiber-optic physicochemical sensor system for the continuous in situ analysis of chlorinated hydrocarbons (CHCs) in water is described. This study took advantage of the selectivity and sensitivity of fiber evanescent wave spectroscopy (FEWS) and the recent development of polycrystalline silver halide fibers. Since these fibers are transparent up to 20 μm, it was possible for the first time to develop a fiber-optic sensing system for CHCs, which have their strongest absorption bands > 10 μm. The silver halide fibers were coated with low-density polyethylene (LDPE) to enrich the CHC within the evanescent wave and to exclude the IR absorbing water from the measurement. For the quantitative in situ FEWS measurements, the coated silver halide fibers were coupled to a Fourier transform infrared (FT-IR) spectrometer using an off-axis parabolic mirror and a fiber-detector coupling system. This setup enabled the simultaneous in situ detection of the most common chlorinated hydrocarbons in concentrations between 1 to 50 mg/L in water by employing a fiber sensing part only 10 cm in length. A comparative analysis of waste water samples under participation of two experienced head space-gas chromatography (HSGC) laboratories showed good agreement of this continuous sensor system with the established standard techniques. The resulting working curve for tetrachloroethylene showed a correlation coefficient of r2 = 0.968 and a relative standard deviation of 17% in the range from 1 to 10 ppm.


1993 ◽  
Vol 47 (5) ◽  
pp. 590-597 ◽  
Author(s):  
Stephane Mottin ◽  
Canh Tran-Minh ◽  
Pierre Laporte ◽  
Raymond Cespuglio ◽  
Michel Jouvet

At pH 7 and with the excitation at wavelengths above 315 nm, previously unreported fluorescence of 5-HT (5-hydroxytryptamine) is observed. Two fluorescence bands were observed for 5-HT; the first emits at around 390 nm with an associated lifetime near 1 ns, and the other (well known) emits at 340 nm with an associated lifetime of 2.7 ns. With both static and time-resolved fluorescences, the spectral and temporal effects of the excitation wavelength were studied between 285 and 340 nm. With these basic spectroscopic properties as a starting point, a fiber-optic chemical sensor (FOCS) was developed in order to measure 5-HT with a single-fiber configuration, nitrogen laser excitation, and fast digitizing techniques. Temporal effects including fluorescence of the optical fiber were studied and compared with measurements both directly in cuvette and through the fiber-optic sensor. Less than thirty seconds are required for each measurement. A detection limit of 5-HT is reached in the range of 5 μM. Our system, with an improved sensitivity, could therefore be a possible and convenient “tool” for in vivo determination of 5-HT.


1991 ◽  
Vol 7 (Supple) ◽  
pp. 1465-1468 ◽  
Author(s):  
YUJI KAWABATA ◽  
KEN-ICHI YASUNAGA ◽  
TOTARO IMASAKA ◽  
NOBUHIKO ISHIBASHI

Author(s):  
B Mulyanti ◽  
Y M R Faozan ◽  
W S Putro ◽  
R E Pawinanto ◽  
A H S Budi ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document