Energy parameters of the temperature-stabilization system in an extracorporeal-circulation system

1978 ◽  
Vol 12 (4) ◽  
pp. 203-206
Author(s):  
A. A. Efremov ◽  
B. S. Bobrov
2018 ◽  
pp. 14-17
Author(s):  
О. Kriukov ◽  
I. Lysak

The relevance of measuring of the pressure of gunpowder gases in the barrel channels of a firearm is noted. The main requirements for a pressure sensor for intra-ballistic measurements are considered. A review of the works in the field of strain gauges error modelling is given. The analysis of the static characteristic of the strain gauge sensor of instantaneous pressure values is carried out. For typical combinations of sensor parameters, a quantitative estimation of the temperature error is performed. To reduce the effect of temperature on the measurement results, it is suggested to take into account the correction in the measurement results, or to apply the temperature stabilization system.


1974 ◽  
Vol 4 (3) ◽  
pp. 137-147
Author(s):  
Takeshi Shimizu ◽  
Yohtaro Iyomasa ◽  
Tetsuya Tajika ◽  
Hiroshi Hikosaka ◽  
Toshio Abe ◽  
...  

Author(s):  
Hiroyuki Ijima ◽  
Taku Matsushita ◽  
Masashi Taga ◽  
Shigehisa Wada ◽  
Keisuke Hamazaki ◽  
...  

2019 ◽  
Vol 11 (S10) ◽  
pp. S1446-S1452
Author(s):  
Alexander Kadner ◽  
Paul Philipp Heinisch ◽  
Maris Bartkevics ◽  
Serena Wyss ◽  
Hans-Joerg Jenni ◽  
...  

Perfusion ◽  
2019 ◽  
Vol 34 (7) ◽  
pp. 590-597 ◽  
Author(s):  
Shekhar Saha ◽  
Sam Varghese ◽  
Mike Herr ◽  
Marcus Leistner ◽  
Christian Ulrich ◽  
...  

Objectives: Minimally invasive extracorporeal circulation circuits provide several advantages compared to conventional extracorporeal circulation circuits. We compared the results of a minimally invasive extracorporeal circulation system with those of conventional extracorporeal circulation system, in patients undergoing isolated coronary artery bypass grafting. Methods: We identified 753 consecutive patients who underwent coronary artery bypass grafting at our centre between October 2014 and September 2016. These patients were divided into two groups: a minimally invasive extracorporeal circulation group (M, n = 229) and a conventional extracorporeal circulation group (C, n = 524). Baseline parameters, details of cardiac surgery as well as postoperative complications and outcomes were compared by means of a propensity-matched analysis of 180 matched pairs. Results: The median EuroSCORE II was 1.3%. Transfusion requirement of packed red blood cells (p = 0.002) was lower in Group M compared to conventional extracorporeal circulation systems. There were no differences in hospital mortality or in rates of adverse events between the matched groups. Total in-hospital mortality of the cohort was 1.7%. Conclusion: The use of minimally invasive extracorporeal circulation is associated with a significantly lower use of blood products after isolated coronary revascularisation. There were no differences concerning duration of surgery, complication rates and mortality between the groups. Therefore, the application of minimally invasive extracorporeal circulation systems should be considered as preferred technique in isolated coronary artery bypass grafting procedures.


2009 ◽  
Vol 15 (8) ◽  
pp. 1187-1193 ◽  
Author(s):  
Anis Nurashikin Nordin ◽  
Ioana Voiculescu ◽  
Mona Zaghloul

Sign in / Sign up

Export Citation Format

Share Document