membrane lung
Recently Published Documents


TOTAL DOCUMENTS

98
(FIVE YEARS 11)

H-INDEX

15
(FIVE YEARS 1)

2021 ◽  
Vol 50 (1) ◽  
pp. 683-683
Author(s):  
Riad Akkari ◽  
Joseph Devlin ◽  
Robert Markie ◽  
David Yamane ◽  
Mustafa Al-mashat

Membranes ◽  
2021 ◽  
Vol 11 (7) ◽  
pp. 464
Author(s):  
Luigi Vivona ◽  
Michele Battistin ◽  
Eleonora Carlesso ◽  
Thomas Langer ◽  
Carlo Valsecchi ◽  
...  

Extracorporeal carbon dioxide removal (ECCO2R) is a promising strategy to manage acute respiratory failure. We hypothesized that ECCO2R could be enhanced by ventilating the membrane lung with a sodium hydroxide (NaOH) solution with high CO2 absorbing capacity. A computed mathematical model was implemented to assess NaOH–CO2 interactions. Subsequently, we compared NaOH infusion, named “alkaline liquid ventilation”, to conventional oxygen sweeping flows. We built an extracorporeal circuit with two polypropylene membrane lungs, one to remove CO2 and the other to maintain a constant PCO2 (60 ± 2 mmHg). The circuit was primed with swine blood. Blood flow was 500 mL × min−1. After testing the safety and feasibility of increasing concentrations of aqueous NaOH (up to 100 mmol × L−1), the CO2 removal capacity of sweeping oxygen was compared to that of 100 mmol × L−1 NaOH. We performed six experiments to randomly test four sweep flows (100, 250, 500, 1000 mL × min−1) for each fluid plus 10 L × min−1 oxygen. Alkaline liquid ventilation proved to be feasible and safe. No damages or hemolysis were detected. NaOH showed higher CO2 removal capacity compared to oxygen for flows up to 1 L × min−1. However, the highest CO2 extraction power exerted by NaOH was comparable to that of 10 L × min−1 oxygen. Further studies with dedicated devices are required to exploit potential clinical applications of alkaline liquid ventilation.


Perfusion ◽  
2021 ◽  
pp. 026765912199142
Author(s):  
George T Harea ◽  
Vitali Karaliou ◽  
Teryn R Roberts ◽  
Jae-Hyek Choi ◽  
Brendan M Beely ◽  
...  

Introduction: Extracorporeal life support (ECLS) patients are at risk for complications caused by gaseous microemboli (GME). GMEs can cause hypoxia, inflammation, coagulation, and end-organ damage. The objective of this in vitro study was to assess dynamics of GME formation during circulation of whole blood or a glycerol blood surrogate. We hypothesized that there is no difference in GME counts and sizes between whole blood and the glycerol blood surrogate and that the membrane lung reduces GME counts over time. Methods: A circulation platform was developed using the Cardiohelp ECLS system to run either donor blood or glycerol solution. We conducted 10 repetitions consisting of three phases of ultrasound GME detection using the EDAC™ Quantifier (Luna Innovations, Charlottesville, VA, USA) for each group. Phases were 3-minute recordings at the initiation of 2 L/min flow (Phase 1), post-injection of a GME suspension (Phase 2), and 10 minutes after injection (Phase 3). The number and size of GME pre- and post-ML were recorded separately and binned based on diameter ranges. Results: In Phase 1, GME count in blood was higher than in glycerol. In Phase 2, there was a large increase in GME counts; however, most GME were reduced post-membrane in both groups. In Phase 3, there was a significant decrease in GME counts compared to Phase 2. GME > 100 μm in glycerol decreased post membrane. Conclusions: We demonstrated GME formation and decay dynamics during in vitro circulation in an ECLS system with blood and glycerol. GME counts were higher in blood, likely due to varying rheological properties. There were decreases in GME levels post membrane in both groups after GME injection, with the membrane lung effectively trapping the GME, and additional reduction 10 minutes after GME injection.


ASAIO Journal ◽  
2021 ◽  
Vol Publish Ahead of Print ◽  
Author(s):  
McKenzie M. Hayes ◽  
Brian P. Fallon ◽  
Ryan P. Barbaro ◽  
Niki Manusko ◽  
Robert H. Bartlett ◽  
...  

Membranes ◽  
2020 ◽  
Vol 11 (1) ◽  
pp. 8
Author(s):  
Matteo Di Nardo ◽  
Filippo Annoni ◽  
Fuhong Su ◽  
Mirko Belliato ◽  
Roberto Lorusso ◽  
...  

Background: Ultra-protective lung ventilation in acute respiratory distress syndrome or early weaning and/or avoidance of mechanical ventilation in decompensated chronic obstructive pulmonary disease may be facilitated by the use of extracorporeal CO2 removal (ECCO2R). We tested the CO2 removal performance of a new ECCO2R (CO2RESET) device in an experimental animal model. Methods: Three healthy pigs were mechanically ventilated and connected to the CO2RESET device (surface area = 1.8 m2, EUROSETS S.r.l., Medolla, Italy). Respiratory settings were adjusted to induce respiratory acidosis with the adjunct of an external source of pure CO2 (target pre membrane lung venous PCO2 (PpreCO2): 80–120 mmHg). The amount of CO2 removed (VCO2, mL/min) by the membrane lung was assessed directly by the ECCO2R device. Results: Before the initiation of ECCO2R, the median PpreCO2 was 102.50 (95.30–118.20) mmHg. Using fixed incremental steps of the sweep gas flow and maintaining a fixed blood flow of 600 mL/min, VCO2 progressively increased from 0 mL/min (gas flow of 0 mL/min) to 170.00 (160.00–200.00) mL/min at a gas flow of 10 L/min. In particular, a high increase of VCO2 was observed increasing the gas flow from 0 to 2 L/min, then, VCO2 tended to progressively achieve a steady-state for higher gas flows. No animal or pump complications were observed. Conclusions: Medium-flow ECCO2R devices with a blood flow of 600 mL/min and a high surface membrane lung (1.8 m2) provided a high VCO2 using moderate sweep gas flows (i.e., >2 L/min) in an experimental swine models with healthy lungs.


Critical Care ◽  
2020 ◽  
Vol 24 (1) ◽  
Author(s):  
Bishoy Zakhary ◽  
Leen Vercaemst ◽  
Phillip Mason ◽  
Marta V. Antonini ◽  
Roberto Lorusso ◽  
...  

Perfusion ◽  
2020 ◽  
Vol 35 (8) ◽  
pp. 878-879
Author(s):  
Bishoy Zakhary ◽  
Jayne Sheldrake ◽  
Vincent Pellegrino

Perfusion ◽  
2020 ◽  
Vol 35 (8) ◽  
pp. 875-877
Author(s):  
Kaspar F Bachmann ◽  
David Berger

Perfusion ◽  
2019 ◽  
Vol 35 (4) ◽  
pp. 348-350
Author(s):  
Sheng Zhang ◽  
Ronghai Lin ◽  
Yongpo Jiang ◽  
YaFei Mi ◽  
Yinghe Xu

A 55-year-old man who suffered from acute myocardial infarction complicated with cardiogenic shock was administered veno-arterial extracorporeal membrane oxygenation. Ultra-high pre-membrane lung oxygen saturation of 93% was observed. Transthoracic echocardiography revealed the presence of patent foramen ovale. The four-chamber view showed that the tip of the cannula was located in the patent foramen ovale, which resulted in a left-to-right shunt. Without adjusting the position of the drainage cannula, the patient was weaned from extracorporeal membrane oxygenation at 136 hours after initiation and survived to hospital discharge.