Transcatheter closure of a patent arterial duct in a patient on veno-arterial extracorporeal membrane oxygenation

2002 ◽  
Vol 28 (4) ◽  
pp. 501-503 ◽  
Author(s):  
Kate L. Brown ◽  
Lara S. Shekerdemian ◽  
Daniel J. Penny
2010 ◽  
Vol 20 (04) ◽  
pp. 462-464 ◽  
Author(s):  
Neven Cace ◽  
Vladimir Ahel ◽  
Iva Bilic

2005 ◽  
Vol 15 (4) ◽  
pp. 373-378 ◽  
Author(s):  
Ronald B. Tanke ◽  
Otto Daniëls ◽  
Arno F. van Heijst ◽  
Henk van Lier ◽  
Cees Festen

Our aim was to analyze left ventricular fractional shortening during extracorporeal membrane oxygenation under the influence of changing volume loading conditions induced by a ductal left-to-right shunt. In all patients, the fractional shortening was observed using echocardiography before, during, and after bypass, irrespective of the presence or absence of the ductal left-to-right shunt. During membrane oxygenation, there was a significant decrease in fractional shortening (p less than 0.001), with no difference before and after membrane oxygenation. A greater decrease in fractional shortening was observed in the group with a ductal left-to-right shunt when compared to patients lacking the ductal shunt (p less than 0.006). The diastolic diameter of the left ventricle also increased significantly during the membrane oxygenation in those patients with left-to-right ductal shunting. Moreover, the patients with left-to-right shunting showed a very severe decreased fractional shortening, lower than 10 per cent, with significantly greater frequency (p less than 0.05) during the course of membrane oxygenation. Conclusion: An important decrease in left ventricular fractional shortening is observed during veno-arterial extracorporeal membrane oxygenation. Left-to-right shunting during bypass, as seen in the patients with patency of the arterial duct, increases the loading conditions on the left ventricle, and produces a significant increase in left ventricular diastolic dimensions. Despite the effects of volume loading produced by the ductal shunt during bypass, the decrease in fractional shortening is significantly more pronounced for these patients. Therefore, during membrane oxygenation the volume loading produced by the ductal shunt is unable to prevent a decrease in left ventricular fractional shortening.


2001 ◽  
Vol 87 (1) ◽  
pp. 76-81 ◽  
Author(s):  
Henri Justino ◽  
Robert N Justo ◽  
Caroline Ovaert ◽  
Alan Magee ◽  
Kyong-Jin Lee ◽  
...  

2014 ◽  
Vol 41 (1) ◽  
pp. 83-86
Author(s):  
Liang Tang ◽  
Shenghua Zhou ◽  
Xiangqian Shen

Percutaneous closure of patent arterial ducts with the Amplatzer Ductal Occluder has become an effective and widely accepted alternative to surgical management. Although rarely, the occluder can be dislodged after an initially successful deployment, and with catastrophic consequences. We describe such a case in a 12-month-old girl who underwent transcatheter closure of a patent arterial duct. After device deployment, the occluder embolized in the patient's descending thoracic aorta, and severe spinal cord ischemic injury resulted. To our knowledge, ours is the first report of this complication after the deployment of an Amplatzer Ductal Occluder. We discuss pathophysiologic mechanisms that could expose patients to the risk of device dislodgment, and we review the relevant medical literature.


2000 ◽  
Vol 10 (3) ◽  
pp. 265-267 ◽  
Author(s):  
François Godart ◽  
Josep Rodés ◽  
Christian Rey

AbstractSevere mechanical haemolysis occurred in an 11-month-old boy after implantation of the new Amplatzer duct occluder. Temporary balloon occlusion of the aortic ampulla was performed 4 days after the initial procedure leading to prompt abolition of the haemolysis.


2009 ◽  
Vol 19 (2) ◽  
pp. 209-211 ◽  
Author(s):  
Payam Ghazi ◽  
Ali-Mohammad Haji-Zeinali

AbstractWe describe successful closure of a persistently patent arterial duct, using an Amplatzer occluder, in the presence of a large thoracic aortic aneurysm in the area of the ductal ampulla. Although percutaneous closure is more difficult in this setting, because of the risk of traumatising the fragile tissues, it can safely be performed. In our case, it produced a decrease in the size of the aneurysm, and permitted us to delay endovascular repair of the thoracic aorta.


1996 ◽  
Vol 6 (4) ◽  
pp. 327-331 ◽  
Author(s):  
Benjamin Zeevi ◽  
Michael Berant ◽  
Galit Bar-Mor ◽  
Leonard C. Blieden

AbstractIn recent years, the percutaneous closure of small and medium-sized patent arterial ducts has been achieved using occluding spring coils. We describe our experience in 33 patients with this technique using a snare to facilitate the procedure. All patients had a clinically apparent patent arterial duct and underwent an attempt at transcatheter closure at a mean age of 5.6 years. In one patient, the duct was a residual lesion following surgical ligation, and in three was residual following attempted closure with a Rashkind double-umbrella. The mean narrowest diameter of the ducts was 1.9 mm. The coil embolized in two of the first four patients, and subsequent to that experience we used a snare to improve delivery. Of the 33 patients, implantation was successful in 32 (97%) using one [29 patients] or two [two patients] coils and in one by a combination of a double-umbrella device and an occluding spring coil. The mean fluoroscopic screening time for the whole group was 26.5 minutes, this time decreasing to 18.5 minutes in the last 26 patients [p <0.05]. Color-Doppler echocardiogram performed the morning after placement of the coils has shown residual leaks in nine of 32 patients [28%]. At a mean follow-up of 7.6 months, repeated imaging has shown residual leaks in four of these patients [12.5%]. No patient had a residual continuous murmur immediately following occlusion. Based on our results, we conclude that occlusion of small to medium-sized ducts using coils appears to be effective. The use of a snare to hold and manipulate the coil as it is delivered improves both control of the coil and the accuracy of its placement.