scholarly journals An in vitro analysis of medial structures and a medial soft tissue reconstruction in a constrained condylar total knee arthroplasty

2016 ◽  
Vol 25 (8) ◽  
pp. 2646-2655 ◽  
Author(s):  
Kiron K. Athwal ◽  
Hadi El Daou ◽  
Eivind Inderhaug ◽  
William Manning ◽  
Andrew J. Davies ◽  
...  
Orthopedics ◽  
2000 ◽  
Vol 23 (10) ◽  
pp. 1051-1056
Author(s):  
Bryan R Parry ◽  
Theodore J Ganley ◽  
David T Bortel ◽  
Richard Englund ◽  
Timothy E Cooney

2019 ◽  
Vol 33 (07) ◽  
pp. 732-744 ◽  
Author(s):  
Demetrius M. Coombs ◽  
Jessica Churchill ◽  
Paul Cartwright ◽  
Morad Chughtai ◽  
Assem A. Sultan ◽  
...  

AbstractDeep soft tissue defects after complicated primary or revision total knee arthroplasty (TKA) can be devastating to the patient and technically challenging. The purpose of this review was to (1) discuss different methods used to provide coverage for deep defects of the knee following TKA, as well as to (2) report on their success rates. A comprehensive literature search was performed. Reports were only included if they (1) were case series, (2) were level III studies or above (including retrospective cohort studies and meta-analyses), (3) were in English, and (4) discussed the outcome of graft or flap coverage of soft tissue defects after total knee arthroplasty. A total of 28 case series and four retrospective comparative studies were retrieved. In 16 studies, 195 out of 241 patients who received gastrocnemius flaps (81%) experienced successful outcomes. In seven studies including 84 patients that underwent fasciocutaneous flap coverage, over 90% of patients experienced successful outcomes. In the four studies examining 144 patients with delayed versus prophylactic soft tissue reconstruction, up to 81% of patients experienced a successful outcome. Various factors must be taken into consideration when assessing full-thickness defects over a TKA and collaboration between plastic and orthopaedic surgeons is required to select the optimal approach.


2016 ◽  
Vol 31 (7) ◽  
pp. 1529-1538 ◽  
Author(s):  
Allison J. Rao ◽  
Steven J. Kempton ◽  
Brandon J. Erickson ◽  
Brett R. Levine ◽  
Venkat K. Rao

1996 ◽  
Vol 118 (1) ◽  
pp. 130-132 ◽  
Author(s):  
Zong-Ping Luo ◽  
Horng-Chaung Hsu ◽  
James A. Rand ◽  
Kai-Nan An

This study evaluated the effects of soft tissue integrity on patellar tracking and patellofemoral joint force after total knee arthroplasty. The results indicate that partial dissection of the soft tissue integrity in the in vitro biomechanical studies of the patellofemoral joint can alter patellar tracking and joint force significantly, leading to improper conclusions.


Author(s):  
Meredith Perkins ◽  
Julie Lowell ◽  
Christina Arnholt ◽  
Daniel MacDonald ◽  
Anita L. Kerkhof ◽  
...  

2021 ◽  
Vol 29 (1) ◽  
pp. 230949902110020
Author(s):  
Seikai Toyooka ◽  
Hironari Masuda ◽  
Nobuhiro Nishihara ◽  
Takashi Kobayashi ◽  
Wataru Miyamoto ◽  
...  

Purpose: To evaluate the integrity of lateral soft tissue in varus osteoarthritis knee by comparing the mechanical axis under varus stress during navigation-assisted total knee arthroplasty before and after compensating for a bone defect with the implant. Methods: Sixty-six knees that underwent total knee arthroplasty were investigated. The mechanical axis of the operated knee was evaluated under manual varus stress immediately after knee exposure and after navigation-assisted implantation. The correlation between each value of the mechanical axis and degree of preoperative varus deformity was compared by regression analysis. Results: The maximum mechanical axis under varus stress immediately after knee exposure increased in proportion to the degree of preoperative varus deformity. Moreover, the maximum mechanical axis under varus stress after implantation increased in proportion to the degree of preoperative varus deformity. Therefore, the severity of varus knee deformity leads to a progressive laxity of the lateral soft tissue. However, regression coefficients after implantation were much smaller than those measured immediately after knee exposure (0.99 vs 0.20). Based on the results of the regression formula, the postoperative laxity of the lateral soft tissue was negligible, provided that an appropriate thickness of the implant was compensated for the bone and cartilage defect in the medial compartment without changing the joint line. Conclusion: The severity of varus knee deformity leads to a progressive laxity of the lateral soft tissue. However, even if the degree of preoperative varus deformity is severe, most cases may not require additional procedures to address the residual lateral laxity.


2021 ◽  
Vol 16 (1) ◽  
Author(s):  
Ran Zhao ◽  
Yanqing Liu ◽  
Hua Tian

Abstract Background Soft tissue balancing is essential for the success of total knee arthroplasty (TKA) and is mainly dependent on surgeon-defined assessment (SDA) or a gap-balancer (GB). However, an electronic sensor has been developed to objectively measure the gap pressure. This study aimed to evaluate the accuracy of soft tissue balancing using SDA and GB compared with a sensor. Methods Forty-eight patients undergoing TKA (60 knees) were prospectively enrolled. Soft tissue balancing was sequentially performed using SDA, a GB, and an electronic sensor. We compared the SDA, GB, and sensor data to calculate the sensitivity, specificity, and accuracy at 0°, 45°, 90°, and 120° flexion. Cumulative summation (CUSUM) analysis was performed to assess the surgeon’s performance during the sensor introductory phase. Results The sensitivity of SDA was 63.3%, 68.3%, 80.0%, and 80.0% at 0°, 45°, 90°, and 120°, respectively. The accuracy of the GB compared with sensor data was 76.7% and 71.7% at 0° and 90°, respectively. Cohen’s kappa coefficient for the accuracy of the GB was 0.406 at 0° (moderate agreement) and 0.227 at 90° (fair agreement). The CUSUM 0° line achieved good prior performance at case 45, CUSUM 90° and 120° showed a trend toward good prior performance, while CUSUM 45° reached poor prior performance at case 8. Conclusion SDA was a poor predictor of knee balance. GB improved the accuracy of soft tissue balancing, but was still less accurate than the sensor, particularly for unbalanced knees. SDA improved with ongoing use of the sensor, except at 45° flexion.