Effects of β-escin and saponin on the transverse-tubular system and sarcoplasmic reticulum membranes of rat and toad skeletal muscle

1999 ◽  
Vol 437 (6) ◽  
pp. 955-965 ◽  
Author(s):  
B. S. Launikonis ◽  
D. George Stephenson
1967 ◽  
Vol 24 (12) ◽  
pp. 2549-2553 ◽  
Author(s):  
C. M. Bishop ◽  
P. H. Odense

The structure of the white skeletal muscle of the cod (Gadus morhua) is described. The peripheral fibrils are ribbon-like and rectangular in cross section with the long axis normal to the sarcolemma. The inner fibrils are mainly polygonal in cross section. Most of the mitochondria and nuclei are peripheral to the fibrils and next to the sarcolemma. The arrangement of the contractile proteins is typical for striated muscle, and the sarcoplasmic reticulum and transverse tubular system are similar to those in other white skeletal fish muscle. A distinct N-band is apparent with indications of branching and reorientation of the actin filaments. Mitochondria are often closely associated with the Z line.


2005 ◽  
Vol 1668 (1) ◽  
pp. 64-74 ◽  
Author(s):  
J.A. Frías ◽  
J.A. Cadefau ◽  
C. Prats ◽  
M. Morán ◽  
A. Megías ◽  
...  

2010 ◽  
Vol 137 (1) ◽  
pp. 21-41 ◽  
Author(s):  
Marino DiFranco ◽  
Alvaro Herrera ◽  
Julio L. Vergara

Chloride fluxes are the main contributors to the resting conductance of mammalian skeletal muscle fibers. ClC-1, the most abundant chloride channel isoform in this preparation, is believed to be responsible for this conductance. However, the actual distribution of ClC-1 channels between the surface and transverse tubular system (TTS) membranes has not been assessed in intact muscle fibers. To investigate this issue, we voltageclamped enzymatically dissociated short fibers using a two-microelectrode configuration and simultaneously recorded chloride currents (ICl) and di-8-ANEPPS fluorescence signals to assess membrane potential changes in the TTS. Experiments were conducted in conditions that blocked all but the chloride conductance. Fibers were equilibrated with 40 or 70 mM intracellular chloride to enhance the magnitude of inward ICl, and the specific ClC-1 blocker 9-ACA was used to eliminate these currents whenever necessary. Voltage-dependent di-8-ANEPPS signals and ICl acquired before (control) and after the addition of 9-ACA were comparatively assessed. Early after the onset of stimulus pulses, di-8-ANEPPS signals under control conditions were smaller than those recorded in the presence of 9-ACA. We defined as attenuation the normalized time-dependent difference between these signals. Attenuation was discovered to be ICl dependent since its magnitude varied in close correlation with the amplitude and time course of ICl. While the properties of ICl, and those of the attenuation seen in optical records, could be simultaneously predicted by model simulations when the chloride permeability (PCl) at the surface and TTS membranes were approximately equal, the model failed to explain the optical data if PCl was precluded from the TTS membranes. Since the ratio between the areas of TTS membranes and the sarcolemma is large in mammalian muscle fibers, our results demonstrate that a significant fraction of the experimentally recorded ICl arises from TTS contributions.


1976 ◽  
Vol 67 (3) ◽  
pp. 265-293 ◽  
Author(s):  
B Hille ◽  
D T Campbell

A Vaseline gap potentiometric recording and voltage clamp method is developed for frog skeletal muscle fibers. The method is based on the Frankenhaeuser-Dodge voltage clamp for myelinated nerve with modifications to improve the frequency response, to compensate for external series resistance, and to compensate for the complex impedance of the current-passing pathway. Fragments of single muscle fibers are plucked from the semitendinosus muscle and mounted while depolarized by a solution like CsF. After Vaseline seals are formed between fluid pools, the fiber ends are cut once again, the central region is rinsed with Ringer solution, and the feedback amplifiers are turned on. Errors in the potential and current records are assessed by direct measurements with microelectrodes. The passive properties of the preparation are simulated by the "disk" equivalent circuit for the transverse tubular system and the derived parameters are similar to previous measurements with microelectrodes. Action potentials at 5 degrees C are long because of the absence of delayed rectification. Their shape is approximately simulated by solving the disk model with sodium permeability in the surface and tubular membranes. Voltage clamp currents consist primarily of capacity currents and sodium currents. The peak inward sodium current density at 5 degrees C is 3.7 mA/cm2. At 5 degrees C the sodium currents are smoothly graded with increasing depolarization and free of notches suggesting good control of the surface membrane. At higher temperatures a small, late extra inward current appears for small depolarizations that has the properties expected for excitation in the transverse tubular system. Comparison of recorded currents with simulations shows that while the transverse tubular system has regenerative sodium currents, they are too small to make important errors in the total current recorded at the surface under voltage clamp at low temperature. The tubules are definitely not under voltage clamp control.


2006 ◽  
Vol 27 (5-7) ◽  
pp. 275-290 ◽  
Author(s):  
Karin Jurkat-Rott ◽  
Michael Fauler ◽  
Frank Lehmann-Horn

Sign in / Sign up

Export Citation Format

Share Document