Reducing the risk of flexor pollicis longus tendon rupture after volar plate fixation for distal radius fractures: validation of the tendon irritation test

2014 ◽  
Vol 24 (8) ◽  
pp. 1425-1429 ◽  
Author(s):  
Seigo Suganuma ◽  
Kaoru Tada ◽  
Hiroyuki Tsuchiya
2020 ◽  
Vol 09 (03) ◽  
pp. 219-224 ◽  
Author(s):  
Kamil Yamak ◽  
Hüseyin Gökhan Karahan ◽  
Berrak Karatan ◽  
Cemil Kayalı ◽  
Taşkın Altay

Abstract Background The aim of this study is to evaluate the frequency of flexor pollicis longus (FPL) tendon rupture and factors leading to this rupture during the follow-up of patients who underwent volar plate fixation because of distal radius fracture. Patients and Methods A total of 109 distal radius fractures of 102 patients treated with volar plate fixation and periodically followed up for at least 1 year between January 2013 and May 2018 were evaluated. Fractures were categorized according to the AO Foundation/Orthopaedic Trauma Association (AO/OTA) Fracture-Dislocation Classification and Soong's grading was used for classifying volar plate position. All patients operated were inquired retrospectively in terms of flexor tendon rupture. Results Gender distribution revealed 45 females and 57 males. Mean age was 47.9 (range: 17–88) years. Mean period of follow-up was 27 months. Distribution of fractures in accordance with the AO/OTA distal radius classification was 6, 8, 7, 12, 24, 33, 11, and 8 patients with types A2, A3, B1, B2, B3, C1, C2, and C3, respectively. When volar plate positions were analyzed with Soong's classification, it revealed that 79 (72.4%), 23 (21.1%), and 7 (6.5%) plates were grade 0, 1, and 2, respectively. In total, evaluating the three patients with FPL rupture, it revealed that the volar plate was positioned distally during fixation because the fracture line had advanced to the distal of the watershed line, the distal portion of the plate had lost complete connection with the bone, and at this portion, it was observed that the pronator quadratus muscle was not covering the plate entirely (Soong's classification grade 2). Patients did not have additional flexor tendon injury. Conclusion FPL tendon rupture is a rare but serious complication of volar plate fixation performed for distal radius fractures. We believe that appropriate choice of implant and careful surgical technique, along with the close follow-up of patients, with Soong's classification grade-2 volar positions would help in preventing this complication. Level of Evidence This is a Level 3a, differential diagnosis/symptom prevalence study.


Hand Surgery ◽  
2011 ◽  
Vol 16 (03) ◽  
pp. 271-275 ◽  
Author(s):  
Kaoru Tada ◽  
Kazuo Ikeda ◽  
Kenji Shigemoto ◽  
Seigo Suganuma ◽  
Hiroyuki Tsuchiya

We evaluated the presence of "tendon irritation" of flexor pollicis longus (FPL) for cases of distal radius fracture treated with volar plates to prevent FPL tendon rupture. This report details cases of 24 patients. The presence of pain or a sense of incompatibility and subdermal crepitus around the wrist with an active thumb motion were defined as symptoms of FPL tendon irritation. Twelve of 24 patients complained of FPL tendon irritation. The plates were removed in nine of these 12 patients, while tendon injury was found in three cases. The other 12 patients did not complain of FPL tendon irritation. Four of these 12 patients underwent plate removal, and tendon injury was not detected. The results of this study indicate that FPL tendon irritation is likely to appear before tendon rupture. Therefore, FPL tendon rupture might be prevented by plate removal in patients who complained of tendon irritation.


Author(s):  
Anil. K. Bhat ◽  
Ashwath. M. Acharya ◽  
Prajwal P. Mane ◽  
Lakshmikanth. H. Karegowda

Abstract Background Purpose was to correlate flexor pollicis longus tendon (FPL) attrition using Ultrasonography with plate position on radiographs following volar locked compression plate fixation (LCP) in patients who have undergone pronator quadratus (PQ) repair for distal radius fractures. Methods Status of flexor pollicis longus tendon was analyzed by ultrasonography in patients who underwent volar locked compression plating with pronator quadratus repair at a minimum of one year follow up. Soong’s criteria was used to assess the plate position and then correlated the ultrasonography findings of flexor pollicis longus. Results There were 33 patients included in our study, of which 15 belonged to Soong’s grade zero, 10 were grade one and eight were grade two. Flexor pollicis longus attrition was noted in all cases with grade two plating. Conclusion Pronator quadratus repair may not prevent attritional changes in higher grades of Soong’s, hence follow up may be required in these patients to identify attritional changes and early implant removal to prevent complications.


2013 ◽  
Vol 38 (9) ◽  
pp. 1691-1697 ◽  
Author(s):  
Brian J. Chilelli ◽  
Ronak M. Patel ◽  
David M. Kalainov ◽  
Jie Peng ◽  
Li-Qun Zhang