Statistical Comparison of Multiple Methods for the Determination of Dissolved Oxygen Levels in Natural Waters

2002 ◽  
Vol 7 (3) ◽  
pp. 146-148 ◽  
Author(s):  
Matthew E. Johll ◽  
David Poister ◽  
Jill Ferguson
2018 ◽  
Vol 3 (2) ◽  
pp. 95
Author(s):  
Asep Ridwanudin ◽  
Varian Fahmi ◽  
Idham Sumarto Pratama

Oxygen is a vital parameter in aquaculture activities. The decrease of dissolved oxygen levels in aquaculture media should be highly observed, since very low dissolved oxygen conditions (hypoxia) could negatively affect to the growth and survival of fish. Therefore, research on the condition of hypoxia is very important to be studied. This study was conducted in January-February 2013 at the Laboratorium of Fish Reproductive Physiology, Pukyong National University, South Korea to measure oxygen consumption in tilapia Oreochromis niloticus (total length: 14.2 ± 1.4 cm, weight: 31.3 ± 2.0 g) under normal conditions (normoxia) and hypoxia. Measurement was conducted using respirometer (dimension: 20 × 17,5 × 10 cm; volume: 3,5 L) every 10 minutes during four hours of observation. Experiment was conducted with three replications. The results showed that oxygen consumption of tilapia fingerlings in hypoxia conditions (12.09 ± 3.20 mg O2/kg/h) was lower than normoxia (35.67 ± 4.19 mg O2/kg/h) (P<0.01). Continuous hypoxic conditions could negatively affect fish movements, which could ultimately lead to mortality when dissolved oxygen levels are very low. Meanwhile, the results on determination of critical oxygen levels for tilapia showed a dissolved oxygen range of 1.9 ± 0.5 mg/L


2018 ◽  
Vol 3 (2) ◽  
pp. 165
Author(s):  
Vitas Atmadi Prakoso ◽  
Young Jin Chang

Oxygen is a vital parameter in aquaculture activities. The decrease of dissolved oxygen levels in aquaculture media should be highly observed, since very low dissolved oxygen conditions (hypoxia) could negatively affect to the growth and survival of fish. Therefore, research on the condition of hypoxia is very important to be studied. This study was conducted in January-February 2013 at the Laboratorium of Fish Reproductive Physiology, Pukyong National University, South Korea to measure oxygen consumption in tilapia <em>Oreochromis niloticus</em> (total length: 14.2 ± 1.4 cm, weight: 31.3 ± 2.0 g) under normal conditions (normoxia) and hypoxia. Measurement was conducted using respirometer (dimension: 20 × 17,5 × 10 cm; volume: 3,5 L) every 10 minutes during four hours of observation. Experiment was conducted with three replications. The results showed that oxygen consumption of tilapia fingerlings in hypoxia conditions (12.09 ± 3.20 mg O<sub>2</sub>/kg/h) was lower than normoxia (35.67 ± 4.19 mg O<sub>2</sub>/kg/h) (P&lt;0.01). Continuous hypoxic conditions could negatively affect fish movements, which could ultimately lead to mortality when dissolved oxygen levels are very low. Meanwhile, the results on determination of critical oxygen levels for tilapia showed a dissolved oxygen range of 1.9 ± 0.5 mg/L.


Sign in / Sign up

Export Citation Format

Share Document