Laparoscopic ventral hernia repair with the Goretex Dualmesh: long-term results and review of the literature

Hernia ◽  
2005 ◽  
Vol 9 (4) ◽  
pp. 348-352 ◽  
Author(s):  
Ph. Topart ◽  
L. Ferrand ◽  
F. Vandenbroucke ◽  
P. Lozac’h
Hernia ◽  
2021 ◽  
Author(s):  
P. J. O’Dwyer ◽  
C. Chew ◽  
H. Qandeel

Abstract Background Repair of a ventral hernia is increasingly being performed by a laparoscopic approach despite lack of good long term follow up data on outcomes. The aim of this study was to examine the long term performance of a polyester mesh and to assess its elastic properties in patients undergoing laparoscopic ventral hernia repair. Methods All patients being assessed for a ventral hernia repair between August 2011 and November 2013 were placed on a prospective database. Those undergoing laparoscopic repair with a polyester mesh were seen at clinic at one month and one year, while their electronic records were assessed at 34 months (range 24–48 months) and 104 months (range 92–116 months). In addition, CT scans of the abdomen and pelvis performed for any reason on these patients during the follow up period were reviewed by a consultant gastrointestinal radiologist. Mechanical failure testing of the mesh was also performed. Results Thirty-two of the 100 patients assessed for ventral hernia repair had a laparoscopic repair with a polyester mesh. Nineteen (59%) had CT scans performed during the follow-up period. No recurrence was recorded at 34 months, while three (9.4%) had a recurrence at 104 months. Two had central breakdown of the mesh at 81 and 90 months, while 1 presented acutely at 116 months after operation. Mesh had stretched across the defect by an average of 21% (range 5.7–40%) in nine patients. Mechanical testing showed that this mesh lost its elasticity at low forces ranging between 1.8 and 3.2 N/cm. Conclusion This study shows that late recurrence is a problem following laparoscopic ventral hernia repair with polyester mesh. The mesh loses it elasticity at a low force. This combined with degradation of mesh seems the most likely cause of failure. This is unlikely to be a unique problem of polyester mesh and further long-term studies are required to better assess this operative approach to ventral hernia repair.


1982 ◽  
Vol 63 (3) ◽  
pp. 37-40
Author(s):  
B. L. Elyashevich ◽  
F. Sh. Sharafislamov ◽  
R. M. Ramazanov

Developed and applied in patients with hernias of the anterior abdominal wall a method of plasty with own tissues using a mechanical suture. 109 patients with postoperative and recurrent ventral hernias were operated on. This method of ventral hernia repair allows to restore the anatomy and function of the abdominal wall, standardizes and simplifies the technique of the operation, reducing the time of its implementation, and gives 95.4% positive long-term results.


Hernia ◽  
2017 ◽  
Vol 21 (6) ◽  
pp. 917-923 ◽  
Author(s):  
Emilie Liot ◽  
Romain Bréguet ◽  
Valérie Piguet ◽  
Frédéric Ris ◽  
Francesco Volonté ◽  
...  

2011 ◽  
Vol 77 (4) ◽  
pp. 458-465 ◽  
Author(s):  
Jason B. Brill ◽  
Patricia L. Turner

Although most surgeons report using both transfascial sutures and laparoscopically placed tacks to secure prostheses in laparoscopic ventral hernia repair, a significant minority have reported large series in which sutures were omitted. A systematic review of the available literature was conducted for large case series and controlled trials documenting long-term follow-up. Forty-three articles were identified, including 6015 patients whose prostheses were secured with transfascial sutures (with or without tacks), and 2450 patients receiving tacks or staples alone. The mean follow-up time reported was 30.1 months. No significant difference was found in rates of hernia recurrence, mesh removal, prolonged postoperative pain, patient body mass index, or hernia defect size between the two groups. The suture group did experience a significantly higher rate of surgical site infection. Although suture tensile strength is greater than that of tacks, and despite numerous anecdotal reports of hernia recurrence secondary to suture failure or omission, the existing literature does not show superiority of one mesh fixation technique over the other for recurrence, whereas infection rates increase when transfascial suture is used.


Hernia ◽  
2017 ◽  
Vol 21 (4) ◽  
pp. 591-600 ◽  
Author(s):  
E. H. H. Mommers ◽  
B. J. M. Leenders ◽  
W. K. G. Leclercq ◽  
T. S. de Vries Reilingh ◽  
J. A. Charbon

Sign in / Sign up

Export Citation Format

Share Document