Three-dimensional evaluation of angular, linear, and resorption features of maxillary impacted canines on cone-beam computed tomography

2017 ◽  
Vol 34 (1) ◽  
pp. 66-72 ◽  
Author(s):  
İlhan Metin Dağsuyu ◽  
Fatih Kahraman ◽  
Rıdvan Okşayan
2017 ◽  
Vol 2017 ◽  
pp. 1-5 ◽  
Author(s):  
İlhan Metin Dağsuyu ◽  
Rıdvan Okşayan ◽  
Fatih Kahraman ◽  
Mehmet Aydın ◽  
İbrahim Şevki Bayrakdar ◽  
...  

Objectives. To assess the relationship between dental follicle width and maxillary impacted canines’ descriptive and resorptive features with three-dimensional (3D) cone-beam computed tomography (CBCT). Methods. The study comprised 102 patients with cone-beam computed tomography 3D images and a total of 140 impacted canines. The association between maxillary impacted canine dental follicle width and the variables of gender, impaction side (right and left), localization of impacted canine (buccal, central, and palatal), and resorption of the adjacent laterals was compared. Measurements were analyzed with Student’s t-test, Kruskal-Wallis test, and Mann–Whitney U statistical test. Results. According to gender, no statistically significant differences were found in the follicle size of the maxillary impacted canine between males and females (p>0.05). Widths of the follicles were determined for the right and left impaction sides, and no statistically significant relation was found (p>0.05). There were statistically significant differences between root resorption degrees of lateral incisors and maxillary impacted canine follicle width (p<0.05). Statistically significant higher follicle width values were present in degree 2 (mild) resorption than in degree 1 (no) and degree 3 (moderate) resorption samples (p<0.05). Conclusions. No significant correlation was found between follicle width and the variables of gender, impaction side, and localization of maxillary impacted canines. Our study could not confirm that increased dental follicle width of the maxillary impacted canines exhibited more resorption risk for the adjacent lateral incisors.


Diagnostics ◽  
2021 ◽  
Vol 11 (5) ◽  
pp. 757
Author(s):  
Maged Sultan Alhammadi ◽  
Abeer Abdulkareem Al-mashraqi ◽  
Rayid Hussain Alnami ◽  
Nawaf Mohammad Ashqar ◽  
Omar Hassan Alamir ◽  
...  

The study sought to assess whether the soft tissue facial profile measurements of direct Cone Beam Computed Tomography (CBCT) and wrapped CBCT images of non-standardized facial photographs are accurate compared to the standardized digital photographs. In this cross-sectional study, 60 patients with an age range of 18–30 years, who were indicated for CBCT, were enrolled. Two facial photographs were taken per patient: standardized and random (non-standardized). The non-standardized ones were wrapped with the CBCT images. The most used soft tissue facial profile landmarks/parameters (linear and angular) were measured on direct soft tissue three-dimensional (3D) images and on the photographs wrapped over the 3D-CBCT images, and then compared to the standardized photographs. The reliability analysis was performed using concordance correlation coefficients (CCC) and depicted graphically using Bland–Altman plots. Most of the linear and angular measurements showed high reliability (0.91 to 0.998). Nevertheless, four soft tissue measurements were unreliable; namely, posterior gonial angle (0.085 and 0.11 for wrapped and direct CBCT soft tissue, respectively), mandibular plane angle (0.006 and 0.0016 for wrapped and direct CBCT soft tissue, respectively), posterior facial height (0.63 and 0.62 for wrapped and direct CBCT soft tissue, respectively) and total soft tissue facial convexity (0.52 for both wrapped and direct CBCT soft tissue, respectively). The soft tissue facial profile measurements from either the direct 3D-CBCT images or the wrapped CBCT images of non-standardized frontal photographs were accurate, and can be used to analyze most of the soft tissue facial profile measurements.


2020 ◽  
Vol 5 (1) ◽  
Author(s):  
Ateksha Bhardwaj Khanna

Abstract Background Endodontic disease can adversely affect the quality of life and therefore early diagnosis and consequent timely treatment is of paramount importance for the Endodontist. Radiology is an essential component in treatment planning, disease monitoring and assessment of treatment outcome. Periapical radiographs and panoramic radiography are frequently utilised but they provide only two-dimensional representation of three-dimensional structures. The advent of cone beam computed tomography (CBCT) offers three-dimensional accuracy of the hard tissue images with a reasonable cost and this has revolutionised imaging of the dentomaxillofacial structures. This imaging system has been seen to overcome some limitations of conventional radiography, as brought out in this review. The improvement in the accuracy is, however, accompanied at the cost of increased radiation exposure to the patient. Nevertheless, smaller areas of exposure are normally appropriate for endodontic imaging, and adjustment in the exposure parameters can further moderate the effective dose (Loubele et al. 37(6):309-18, 2008). Aims and objectives The aim of this review is to present the pertinent literature on the various applications of cone beam computed tomography in the field of endodontics. Methods Literature was electronically searched on the following sources; Medline and Keats Library. Further, a manual search was performed on the following journals: International Endodontic Journal, Journal of Endodontics, Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology, Endodontology, Journal of Dental Research, European Journal of Oral Sciences & Odontology and Dentomaxillofacial Radiology. A preliminary search was performed to gain an idea of the available literature using keywords ‘Cone Beam Computed Tomography’ to view the volume of the literature evident and identify questions to be addressed in this review. The initial search showed 243 potential articles. After scrutinising the titles and abstracts of the retrieved articles, 70 relevant studies were reviewed in full text. Furthermore, ‘published guidelines on the use of CBCT’ were also searched so as to include the results as an additional source material. All the articles eligible to be included in the review were in the English language and ranged from the year 1960 to the present. Also all the studies reviewed were based on the various uses of cone beam computed tomography in the field of endodontics. The keywords used to search were ‘Cone Beam Computed Tomography (CBCT)’, ‘Conventional radiography’, ‘Applications of CBCT in endodontics’, ‘CBCT and tooth morphology’, ‘CBCT and apical periodontitis’, ‘CBCT and vertical root fractures’, ‘CBCT and resorption’, ‘CBCT and pre-surgical assessment’, ‘CBCT and dento-alveolar trauma’ and ‘CBCT and endodontic outcome’. Results Every case is unique and CBCT should be considered only after studying each case individually. CBCT imaging needs to be adopted or used where information from conventional imaging systems is either inadequate for the management of endodontic problems or inconclusive. Having said that, it is safe to state that CBCT imaging has the potential to become the first choice for endodontic treatment planning and outcome assessment, especially when new scanners with lower radiation doses and enhanced resolution would be available.


2011 ◽  
Vol 140 (5) ◽  
pp. 607-615 ◽  
Author(s):  
Scott Stratemann ◽  
John C. Huang ◽  
Koutaro Maki ◽  
David Hatcher ◽  
Arthur J. Miller

Sign in / Sign up

Export Citation Format

Share Document