Outdoor relative radiometric calibration method using gray scale targets

2013 ◽  
Vol 56 (7) ◽  
pp. 1825-1834 ◽  
Author(s):  
YiNi Duan ◽  
Lei Yan ◽  
Bin Yang ◽  
Xin Jing ◽  
Wei Chen
2020 ◽  
Vol 40 (6) ◽  
pp. 0628002
Author(s):  
许和鱼 Xu Heyu ◽  
张黎明 Zhang Liming ◽  
李鑫 Li Xin ◽  
黄文薪 Huang Wenxin ◽  
司孝龙 Si Xiaolong ◽  
...  

2018 ◽  
Vol 47 (8) ◽  
pp. 817003
Author(s):  
王灵丽 Wang Lingli ◽  
白 杨 Bai Yang ◽  
潘 征 Pan Zheng ◽  
谷文双 Gu Wenshuang ◽  
武红宇 Wu Hongyu

2020 ◽  
Vol 12 (11) ◽  
pp. 1726 ◽  
Author(s):  
Jung-Il Shin ◽  
Yeong-Min Cho ◽  
Pyung-Chae Lim ◽  
Hae-Min Lee ◽  
Ho-Yong Ahn ◽  
...  

As the use of unmanned aerial vehicle (UAV) images rapidly increases so does the need for precise radiometric calibration. For UAV images, relative radiometric calibration is required in addition to the traditional vicarious radiometric calibration due to the small field of view. For relative radiometric calibration, some UAVs install irradiance sensors, but most do not. For UAVs without them, an intelligent scheme for relative radiometric calibration must be applied. In this study, a relative radiometric calibration method is proposed to improve the quality of a reflectance map without irradiance measurements. The proposed method, termed relative calibration by the optimal path (RCOP), uses tie points acquired during geometric calibration to define the optimal paths. A calibrated image from RCOP was compared to validation data calibrated with irradiance measurements. As a result, the RCOP method produces seamless mosaicked images with uniform brightness and reflectance patterns. Therefore, the proposed method can be used as a precise relative radiometric calibration method for UAV images.


Sensors ◽  
2020 ◽  
Vol 21 (1) ◽  
pp. 139
Author(s):  
Shengli Chen ◽  
Xiaobing Zheng ◽  
Xin Li ◽  
Wei Wei ◽  
Shenda Du ◽  
...  

To calibrate the low signal response of the ocean color (OC) bands and test the stability of the Fengyun-3D (FY-3D)/Medium Resolution Spectral Imager II (MERSI-II), an absolute radiometric calibration field test of FY-3D/MERSI-II at the Lake Qinghai Radiometric Calibration Site (RCS) was carried out in August 2018. The lake surface and atmospheric parameters were mainly measured by advanced observation instruments, and the MODerate spectral resolution atmospheric TRANsmittance algorithm and computer model (MODTRAN4.0) was used to simulate the multiple scattering radiance value at the altitude of the sensor. The results showed that the relative deviations between bands 9 and 12 are within 5.0%, while the relative deviations of bands 8, and 13 are 17.1%, and 12.0%, respectively. The precision of the calibration method was verified by calibrating the Aqua/Moderate-resolution Imaging Spectroradiometer (MODIS) and National Polar-orbiting Partnership (NPP)/Visible Infrared Imaging Radiometer (VIIRS), and the deviation of the calibration results was evaluated with the results of the Dunhuang RCS calibration and lunar calibration. The results showed that the relative deviations of NPP/VIIRS were within 7.0%, and the relative deviations of Aqua/MODIS were within 4.1% from 400 nm to 600 nm. The comparisons of three on-orbit calibration methods indicated that band 8 exhibited a large attenuation after launch and the calibration results had good consistency at the other bands except for band 13. The uncertainty value of the whole calibration system was approximately 6.3%, and the uncertainty brought by the field surface measurement reached 5.4%, which might be the main reason for the relatively large deviation of band 13. This study verifies the feasibility of the vicarious calibration method at the Lake Qinghai RCS and provides the basis and reference for the subsequent on-orbit calibration of FY-3D/MERSI-II.


Sign in / Sign up

Export Citation Format

Share Document