Highly sensitive detection of melamine based on reversed phase liquid chromatography mass spectrometry

2009 ◽  
Vol 54 (5) ◽  
pp. 732-737 ◽  
Author(s):  
QingQing Wu ◽  
KeXin Fan ◽  
Wei Sha ◽  
HongQiang Ruan ◽  
Rong Zeng ◽  
...  
1979 ◽  
Vol 51 (14) ◽  
pp. 2324-2328 ◽  
Author(s):  
B. L. Karger ◽  
D. P. Kirby ◽  
Paul. Vouros ◽  
R. L. Foltz ◽  
B. Hidy

Author(s):  
Rainer Stoffel ◽  
Michael A. Quilliam ◽  
Normand Hardt ◽  
Anders Fridstrom ◽  
Michael Witting

Abstract Chromatographic retention time information is valuable, orthogonal information to MS and MS/MS data that can be used in metabolite identification. However, while comparison of MS data between different instruments is possible to a certain degree, retention times (RTs) can vary extensively, even when nominally the same phase system is used. Different factors such as column dead volumes, system extra column volume, and gradient dwell volume can influence absolute retention times. Retention time indexing (RTI), routinely employed in gas chromatography (e.g., Kovats index), allows compensation for deviations in experimental conditions. Different systems have been reported for RTI in liquid chromatography, but none of them have been applied to metabolomics to the same extent as they have with GC. Recently, a more universal RTI system has been reported based on a homologous series of N-alkylpyridinium sulfonates (NAPS). These reference standards ionize in both positive and negative ionization modes and are UV-active. We demonstrate the NAPS can be used for retention time indexing in reversed-phase-liquid chromatography-mass spectrometry (RP-LC–MS)–based metabolomics. Having measured >500 metabolite standards and varying flow rate and column dimension, we show that conversion of RT to retention indices (RI) substantially improves comparability of retention information and enables to use of RI for metabolite annotation and identification.


Sign in / Sign up

Export Citation Format

Share Document