reversed phase liquid chromatography
Recently Published Documents


TOTAL DOCUMENTS

2183
(FIVE YEARS 160)

H-INDEX

101
(FIVE YEARS 7)

2022 ◽  
pp. 462818
Author(s):  
Gino Groeneveld ◽  
Melissa N. Dunkle ◽  
Matthias Pursch ◽  
Edwin P.C. Mes ◽  
Peter J. Schoenmakers ◽  
...  

Author(s):  
Martin Meyer ◽  
Lidia Montero ◽  
Sven W. Meckelmann ◽  
Oliver J. Schmitz

AbstractThis work presents a comparative study for the analysis of carbohydrates for four common chromatographic methods, each coupled to mass spectrometry. Supercritical fluid chromatography (SFC), hydrophilic interaction liquid chromatography (HILIC), reversed-phase liquid chromatography (RP-LC) and gas chromatography (GC) with detection by triple quadrupole mass spectrometer (QqQ-MS) are compared. It is shown that gas chromatography and reversed-phase liquid chromatography, each after derivatisation, are superior to the other two methods in terms of separation performance. Furthermore, comparing the different working modes of the mass spectrometer, it can be determined that a targeted analysis, i.e. moving from full scan to single ion monitoring (SIM) and multiple reaction monitoring (MRM), results in an improvement in the sensitivity as well as the repeatability of the method, which has deficiencies especially in the analysis using HILIC. Overall, RP-LC–MS in MRM after derivatisation with 1-phenyl-3-methyl-5-pyrazolone (PMP) proved to be the most suitable method in terms of separation performance, sensitivity and repeatability for the analysis of monosaccharides. Detection limits in the nanomolar range were achieved, which corresponds to a mass concentration in the low µg/L range. The applicability of this method to different biological samples was investigated with various herbal liquors, pectins and a human glycoprotein. Graphical abstract


Author(s):  
Rainer Stoffel ◽  
Michael A. Quilliam ◽  
Normand Hardt ◽  
Anders Fridstrom ◽  
Michael Witting

Abstract Chromatographic retention time information is valuable, orthogonal information to MS and MS/MS data that can be used in metabolite identification. However, while comparison of MS data between different instruments is possible to a certain degree, retention times (RTs) can vary extensively, even when nominally the same phase system is used. Different factors such as column dead volumes, system extra column volume, and gradient dwell volume can influence absolute retention times. Retention time indexing (RTI), routinely employed in gas chromatography (e.g., Kovats index), allows compensation for deviations in experimental conditions. Different systems have been reported for RTI in liquid chromatography, but none of them have been applied to metabolomics to the same extent as they have with GC. Recently, a more universal RTI system has been reported based on a homologous series of N-alkylpyridinium sulfonates (NAPS). These reference standards ionize in both positive and negative ionization modes and are UV-active. We demonstrate the NAPS can be used for retention time indexing in reversed-phase-liquid chromatography-mass spectrometry (RP-LC–MS)–based metabolomics. Having measured >500 metabolite standards and varying flow rate and column dimension, we show that conversion of RT to retention indices (RI) substantially improves comparability of retention information and enables to use of RI for metabolite annotation and identification.


2021 ◽  
pp. 462792
Author(s):  
Elizaveta S. Fedorova ◽  
Dmitriy D. Matyushin ◽  
Ivan V. Plyushchenko ◽  
Andrey N. Stavrianidi ◽  
Aleksey K. Buryak

Author(s):  
Josefine Carlsson ◽  
Francesco Iadaresta ◽  
Jonas Eklund ◽  
Rozanna Avagyan ◽  
Conny Östman ◽  
...  

AbstractThe global manufacturing of clothing is usually composed of multistep processes, which include a large number of chemicals. However, there is generally no information regarding the chemical content remaining in the finished clothes. Clothes in close and prolonged skin contact may thus be a significant source of daily human exposure to hazardous compounds depending on their ability to migrate from the textiles and be absorbed by the skin. In the present study, twenty-four imported garments on the Swedish market were investigated with respect to their content of organic compounds, using a screening workflow. Reversed-phase liquid chromatography coupled to electrospray ionization/high-resolution mass spectrometry was used for both suspect and non-target screening. The most frequently detected compound was benzothiazole followed by quinoline. Nitroanilines with suspected mutagenic and possible skin sensitization properties, and quinoline, a carcinogenic compound, were among the compounds occurring at the highest concentrations. In some garments, the level of quinoline was estimated to be close to or higher than 50,000 ng/g, the limit set by the REACH regulation. Other detected compounds were acridine, benzotriazoles, benzothiazoles, phthalates, nitrophenols, and organophosphates. Several of the identified compounds have logP and molecular weight values enabling skin uptake. This pilot study indicates which chemicals and compound classes should be prioritized for future quantitative surveys and control of the chemical content in clothing as well as research on skin transfer, skin absorption, and systemic exposure. The results also show that the current control and prevention from chemicals in imported garments on the Swedish market is insufficient. Graphical abstract


Sign in / Sign up

Export Citation Format

Share Document