scholarly journals Distal Radius Fractures and the Volar Lunate Facet Fragment: Kirschner Wire Fixation in Addition to Volar-Locked Plating

Hand ◽  
2013 ◽  
Vol 9 (2) ◽  
pp. 230-236 ◽  
Author(s):  
Amy M. Moore ◽  
David G. Dennison
2015 ◽  
Vol 22 (07) ◽  
pp. 944-948
Author(s):  
Qazi Muhammad Furquan ◽  
Naveed Ahmed Solangi ◽  
Muhammad Bux Chachar ◽  
Ghulam Mustafa Kaimkhani ◽  
Malik Wasim Ahmed ◽  
...  

Objectives: To determine functional outcome of percutaneous Kirschner wirefixation and short arm cast in intra-articular distal radius fractures in patients of 20-70 years.Study Design: Descriptive case series. Setting: Department of Orthopedic Surgery, DowUniversity of Health Sciences / Civil Hospital Karachi. Period: 1st April, 2013 to 30th September,2013. Methods: A total of 62 patients with closed type III distal fractures according to Frykmanclassification were included in this study. Patient lying in supine position and after generalanesthesia, closed reduction was done with the forearm in prone position, aiming to restorenormal anatomical position. Two Kirschner wires were inserted from radial styloid process inparallel and oblique fashion to the medial cortex of the radius and one transversely from lateralto medial for intra-articular fragments. Final functional outcome was assessed after 12 weeks ofsurgery and recorded on pre-designed Proforma. Results: Acceptable functional outcome ofpercutaneous Kirschner wire fixation and short arm cast in intra-articular distal radius fractureswas observed in 80.65% (50/62) cases. Conclusions: It is concluded that functional outcomeof percutaneous Kirschner wire fixation and short arm cast procedure is satisfactory in intraarticulardistal radius fractures and it appears to be an easy, technically less demanding andeffective method for stabilization, so this procedure can be applied for patients with thesefractures.


2010 ◽  
Vol 18 (1) ◽  
pp. 85-86 ◽  
Author(s):  
Palaniappan Lakshmanan ◽  
Varun Dixit ◽  
Mike R Reed ◽  
Joel Lester Sher

2012 ◽  
Vol 16 (3) ◽  
pp. 120-123 ◽  
Author(s):  
Padmanabhan Subramanian ◽  
Shanjitha Kantharuban ◽  
Sophie Shilston ◽  
Oliver James Pearce

Hand ◽  
2020 ◽  
pp. 155894472097640
Author(s):  
Nathaniel Fogel ◽  
Lauren M. Shapiro ◽  
Allison Roe ◽  
Sahitya Denduluri ◽  
Marc J. Richard ◽  
...  

Background Intra-articular distal radius fractures with small volar lunate facet fragments can be challenging to address with volar plate fixation alone. Volar locked plating with supplementary spring wire fixation has been previously described in a small series but has not been further described in the literature. We hypothesized that this technique can provide adequate fixation for volar lunate facet fragments smaller than 15 mm in length, which are at risk of displacement. Methods We completed a retrospective chart review (2015-2019) of patients who underwent volar locked plating with the addition of supplementary spring wire fixation for intra-articular distal radius fractures with a volar lunate facet fragment (<15 mm). Postoperative radiographs were assessed to evaluate union, evidence of hardware failure, escape of the volar lunate facet fragment, and postoperative volar tilt. Clinical outcome was assessed with wrist flexion/extension, arc of pronosupination, and Quick Disabilities of the Arm, Shoulder, and Hand Score ( QuickDASH) scores. Results Fifteen patients were identified, of which all went on to fracture union. There were no hardware failures or escape of the volar lunate facet fragment at final follow-up. One patient underwent hardware removal for symptoms of flexor tendon irritation. The mean wrist flexion was 59°, wrist extension was 70°, pronation was 81°, and supination was 76°. The mean QuickDASH score was 18.5. The mean postoperative volar tilt was 3.6°. Conclusions Supplementary spring wire fixation with standard volar plating provides stable fixation for lunate facet fragments less than 15 mm. This technique is a safe and reliable alternative to commercially available fragment-specific implants.


Author(s):  
Liam Sanders ◽  
Nick Johnson ◽  
Joseph J. Dias

Abstract Background There is currently no consensus for the optimum configuration and number of Kirschner wires (K-wires) to use for the stabilization of dorsally displaced distal radius fractures. In this biomechanical study, we compared the load to failure and stiffness of four common K-wire configurations to identify the strongest construct for use in extra-articular dorsally displaced distal radius fractures. Case Description We created a standard distal radius fracture model in turkey tarsometatarsi which was stabilized using two or three K-wires (1.6 mm) in four different configurations. Following a power calculation, 10 fracture models of each configuration underwent testing in cantilever bending and axial compression. Literature Review Recent randomized trials have shown no evidence that volar locking plates are superior to K-wires for the treatment of dorsally displaced distal radius fractures. This has led to an increase in the popularity of much cheaper K-wires. Several different K-wire techniques have been described but there is no strong evidence to determine which is the optimal configuration and number of wires. Clinical Relevance The three-wire interfragmentary configuration was stiffer than the three-wire Kapandji in axial compression and cantilever bending. There was no difference in load to failure in cantilever bending or axial compression. The three-wire interfragmentary technique is the stiffest configuration of K-wires for dorsally displaced distal radius fractures. The two-wire Kapandji technique was significantly weaker than the other configurations, especially in cantilever bending. Conclusion The authors recommend to always use three wires for percutaneous pinning and never to use two intrafocal wires alone.


Hand ◽  
2021 ◽  
pp. 155894472110289
Author(s):  
Anthony L. Logli ◽  
Marco Rizzo

Background: Owing to the many unique disease characteristics of Parkinson disease (PD)—namely resting tremors, muscular rigidity, and poor bone quality—we hypothesized that this patient population would have inferior outcomes with surgical management of acute distal radius fractures (DRFs) compared with the literature available on the general population. Methods: This is a retrospective observational study performed at a single, level 1, academic center from 2001 to 2020 capturing all adult patients with an isolated, acute, and closed DRF that ultimately underwent operative treatment. International Classification of Diseases 10 codes were used to identify 30 patients for manual chart review. Several patient and fracture characteristics were accounted for and complications, reoperations, and failures of surgical intervention were recorded. Results: There was a total of 7/30 failures (23%), 6/30 reoperations (20%), and 12 complications in 9/30 wrists (complication rate, 30%) at a mean latest follow-up of 11 months (1.2-158 months). Of the 7 failures, 5 were due to loss of reduction, and 2 of them were deep infections with mean time to failure of 8.3 weeks (range, 11 days-5.2 months). Conclusions: This study found a high rate of complications, reoperations, and early failure despite a short follow-up period and a small cohort of patients with PD treated surgically for a DRF. We recommend locked plating if suitable for the fracture type and early involvement of a multidisciplinary team to assist with medical optimization of PD to increase chances of a successful outcome.


Sign in / Sign up

Export Citation Format

Share Document