Outcomes of Supplementary Spring Wire Fixation With Volar Plating for Volar Lunate Facet Fragments in Distal Radius Fractures

Hand ◽  
2020 ◽  
pp. 155894472097640
Author(s):  
Nathaniel Fogel ◽  
Lauren M. Shapiro ◽  
Allison Roe ◽  
Sahitya Denduluri ◽  
Marc J. Richard ◽  
...  

Background Intra-articular distal radius fractures with small volar lunate facet fragments can be challenging to address with volar plate fixation alone. Volar locked plating with supplementary spring wire fixation has been previously described in a small series but has not been further described in the literature. We hypothesized that this technique can provide adequate fixation for volar lunate facet fragments smaller than 15 mm in length, which are at risk of displacement. Methods We completed a retrospective chart review (2015-2019) of patients who underwent volar locked plating with the addition of supplementary spring wire fixation for intra-articular distal radius fractures with a volar lunate facet fragment (<15 mm). Postoperative radiographs were assessed to evaluate union, evidence of hardware failure, escape of the volar lunate facet fragment, and postoperative volar tilt. Clinical outcome was assessed with wrist flexion/extension, arc of pronosupination, and Quick Disabilities of the Arm, Shoulder, and Hand Score ( QuickDASH) scores. Results Fifteen patients were identified, of which all went on to fracture union. There were no hardware failures or escape of the volar lunate facet fragment at final follow-up. One patient underwent hardware removal for symptoms of flexor tendon irritation. The mean wrist flexion was 59°, wrist extension was 70°, pronation was 81°, and supination was 76°. The mean QuickDASH score was 18.5. The mean postoperative volar tilt was 3.6°. Conclusions Supplementary spring wire fixation with standard volar plating provides stable fixation for lunate facet fragments less than 15 mm. This technique is a safe and reliable alternative to commercially available fragment-specific implants.

Hand ◽  
2019 ◽  
Vol 15 (5) ◽  
pp. 698-706
Author(s):  
Tyler S. Pidgeon ◽  
Peter Casey ◽  
Rita E. Baumgartner ◽  
Harrison Ferlauto ◽  
David S. Ruch

Although volar locked plating (VLP) of distal radius fractures is common, complications remain a considerable concern for upper extremity specialists using modern techniques. Complications following VLP of DR fractures were recorded prospectively from January 2005 to January 2017. Fractures were characterized using the AO classification, and complications were described by severity. Severe complications required operative treatment and/or resulted in permanent impairment, moderate complications required nonoperative treatment, and mild complications resolved without intervention. The available Current Procedural Terminology data for uncomplicated VLP were used to calculate the complication rate. Statistical analysis compared severe and nonsevere complications. Thirty-seven patients (27 women; 39 radii) experienced complications following VLP of DR fractures, resulting in a complication rate of 13.2%. For those with complications, the mean age was 48.5 ± 13.5 years (range: 19-78 years) and the mean follow-up was 13.7 ± 9.0 months (range: 3-36 months). A majority (28/39: 71.8%) had type C fractures. The most common complications were hardware complication requiring removal (18) and malunion (6). There were only 3 tendon ruptures. There were 25 unplanned returns to the operating room in 24 radii (22 patients). The most common reason was removal of hardware (18). Patients with severe complications more commonly had AO type C fractures and required longer follow-up. Modern VLP of DR fractures has a complication rate of 13.2%. Hardware complication requiring removal was the most notable complication of VLP. Tendon rupture has become rare with modern techniques. AO type C fractures were associated with more severe complications.


Hand ◽  
2020 ◽  
pp. 155894472091834
Author(s):  
William L. Wang ◽  
Jack Abboudi ◽  
Gregory Gallant ◽  
Christopher Jones ◽  
William Kirkpatrick ◽  
...  

Background: Scapholunate (SL) ligament injuries can occur concomitantly with distal radius fractures (DRFs), and the management of acute SL injury in the setting of DRFs remains controversial. The purpose of the study is to identify the radiographic incidence of SL widening in DRF treated with volar plate fixation and to determine the functional outcomes of DRF with concomitant radiographic SL-widening. Methods: One hundred and seventeen patients with DRFs, with and without radiographic SL-widening, and treated with volar locked plating, were prospectively enrolled. No SL ligament repairs or reconstructions were performed in any cases. Patients with DRFs with radiographic criteria for SL widening were compared to those without. Patients were evaluated at 3 months and 1 year postoperatively with Quick Disabilities of the Arm, Shoulder, and Hand and Patient-Rated Wrist Evaluation (PRWE) questionnaires. Results: Thirty-one patients (26.5%) were found to have radiographic evidence of SL widening. Patients with concomitant SL widening had less wrist extension at 3 months (52.4 degrees vs 60.8, P = .034) and at 1 year (64.5 degrees vs 71.8, P = .023). The group with SL widening had greater articular step off at 3 months (0.33 vs 0.06, P = .042), but no difference at 1 year (0.11 vs 0.05, P = .348). There were no differences in wrist flexion, supination, pronation, volar tilt, radial inclination, radial height, ulnar variance, PRWE scores, and Quick Dash scores at 3 months and 1 year. Conclusions: Radiographic SL-widening is a common finding associated with DRFs undergoing surgical repair. There are similar clinical outcomes between those with untreated SL widening compared to those without an SL widening at 1-year postoperatively.


Author(s):  
Guido W. Van Oijen ◽  
Esther M. M. Van Lieshout ◽  
Maarten R. L. Reijnders ◽  
Anand Appalsamy ◽  
Tjebbe Hagenaars ◽  
...  

Abstract Purpose This systematic literature review aimed to make a detailed overview on the clinical and functional outcomes and to get insight into the possible superiority of a treatment method for extra-articular distal radius fractures. Methods Embase, Medline, Cochrane Library, Web of Science, and Google Scholar were searched for studies describing treatment results. Five treatment modalities were compared: plaster cast immobilization, K-wire fixation, volar plating, external fixation, and intramedullary fixation. Results Out of 7,054 screened studies, 109 were included in the analysis. Overall complication rate ranged from 9% after plaster cast treatment to 18.5% after K-wire fixation. For radiographic outcomes, only volar tilt in the plaster cast group was lower than in the other groups. Apart from better grip strength after volar plating, no clear functional differences were found across treatment groups. Conclusion Current literature does not provide uniform evidence to prove superiority of a particular treatment method when looking at complications, re-interventions, and long-term functional outcomes.


Hand ◽  
2021 ◽  
pp. 155894472110289
Author(s):  
Anthony L. Logli ◽  
Marco Rizzo

Background: Owing to the many unique disease characteristics of Parkinson disease (PD)—namely resting tremors, muscular rigidity, and poor bone quality—we hypothesized that this patient population would have inferior outcomes with surgical management of acute distal radius fractures (DRFs) compared with the literature available on the general population. Methods: This is a retrospective observational study performed at a single, level 1, academic center from 2001 to 2020 capturing all adult patients with an isolated, acute, and closed DRF that ultimately underwent operative treatment. International Classification of Diseases 10 codes were used to identify 30 patients for manual chart review. Several patient and fracture characteristics were accounted for and complications, reoperations, and failures of surgical intervention were recorded. Results: There was a total of 7/30 failures (23%), 6/30 reoperations (20%), and 12 complications in 9/30 wrists (complication rate, 30%) at a mean latest follow-up of 11 months (1.2-158 months). Of the 7 failures, 5 were due to loss of reduction, and 2 of them were deep infections with mean time to failure of 8.3 weeks (range, 11 days-5.2 months). Conclusions: This study found a high rate of complications, reoperations, and early failure despite a short follow-up period and a small cohort of patients with PD treated surgically for a DRF. We recommend locked plating if suitable for the fracture type and early involvement of a multidisciplinary team to assist with medical optimization of PD to increase chances of a successful outcome.


2021 ◽  
Vol 108 (Supplement_2) ◽  
Author(s):  
J Mulrain ◽  
K Joshi ◽  
F Doyle ◽  
A Abdulkarim

Abstract Introduction Distal radius fractures are common and trends for fixation have changed with increased use of volar locking plates in recent time. A meta-analysis will summarise the best evidence for treatment. Method A systematic review was conducted using PRISMA methodology to identify studies that reported clinical and/or radiological outcomes in patients with AO type C distal radius fractures when treated with external fixation versus ORIF. Results 10 randomised trials were included in this review, reporting on 967 patients. Clinical outcomes are in favour of volar plating at 3 months post-operation, but no difference between the two groups is seen at 6 or 12 months. Analysis of complication rates shows a minute increase in risk-ratio for volar plating versus external fixation. Subgroup analysis showed significantly higher re-operations after plate fixation and significantly higher infection after external fixation. Conclusions Internal fixation of complex distal radius fractures confers an improved clinical outcome at early follow up only and a minimally increased risk of complications. The improved grip strength with volar plating is only superior at early follow up and no long-term superiority is seen with either intervention. The type of surgery in this injury type therefore remains at the surgeon’s consideration on a case-by-case basis.


2014 ◽  
Vol 15 (1) ◽  
Author(s):  
Paul Ruckenstuhl ◽  
Gerwin A Bernhardt ◽  
Patrick Sadoghi ◽  
Mathias Glehr ◽  
Lukas A Holzer ◽  
...  

Author(s):  
M. Carolina Orbay ◽  
Jorge L. Orbay

AbstractGreater understanding of specific fracture patterns following distal radius fractures has arisen with the advent of volar plating. The volar marginal fragment (VMF) is a small peripheral piece of bone which is critical to carpal stability. Failure to achieve good fixation of the VMF can result in volar subluxation of the carpus and distal radioulnar joint instability. Due to its small, distal nature, this fragment can be easily missed and difficult to fix. Loss of reduction of the VMF following operative fixation presents specific challenges and surgical considerations dictated by patient characteristics and timing. Our goal of this review is to present a classification system for these failed VMFs which can help guide surgical treatment as well as expected outcomes.


2013 ◽  
Vol 26 (4) ◽  
pp. 248
Author(s):  
Ki-Chan An ◽  
Gyu-Min Kong ◽  
Jang-Seok Choi ◽  
Hi-Chul Gwak ◽  
Joo-Yong Kim ◽  
...  

2017 ◽  
Vol 43 (2) ◽  
pp. 142-147 ◽  
Author(s):  
Daniel Martinez-Mendez ◽  
Alejandro Lizaur-Utrilla ◽  
Joaquin de-Juan-Herrero

We compared outcomes in elderly patients with intra-articular distal radius fractures treated by closed reduction and plaster immobilization or open reduction and internal fixation with a volar plate. Ninety-seven patients older than 60 years were randomly allocated to conservative (47 patients) or surgical (50 patients) treatment. Over a 2-year period, we assessed patient-rated wrist evaluation score, DASH (disability arm, shoulder and hand) questionnaire, pain, wrist range of motion, grip strength, and radiological parameters. The functional outcomes and quality of life were significantly better after volar plating fixation compared with conservative treatment. We found that restoration of the articular surface, radial inclination, and ulnar variance affected the outcomes, but the articular step-off did not. Twenty-five per cent of the patients with conservative treatment had secondary loss of reduction. We conclude that surgical plating leads to better outcomes than conservative treatment for elderly patients with intra-articular distal radius fractures. Level of evidence: I


Sign in / Sign up

Export Citation Format

Share Document