Value of gated-SPECT MPI for ischemia-guided PCI of non-culprit vessels in STEMI patients with multivessel disease after primary PCI

2018 ◽  
Vol 25 (5) ◽  
pp. 1616-1620
Author(s):  
Lawrence M. Phillips ◽  
João V. Vitola ◽  
Leslee J. Shaw ◽  
Raffaele Giubbini ◽  
Ganesan Karthikeyan ◽  
...  
2020 ◽  
Vol 10 (1) ◽  
Author(s):  
Amalia Peix ◽  
Kenia Padrón ◽  
Lázaro O. Cabrera ◽  
Osmín Castañeda ◽  
Danet Milán ◽  
...  

Abstract Purpose To analyze the evolution post-cardiac resynchronization therapy (CRT) in left ventricular non-compaction (LVNC) cardiomyopathy (CM) patients compared to other types of CM, according to clinical and functional variables, by using gated-SPECT myocardial perfusion imaging (MPI). Methods Ninety-three patients (60 ± 11 years, 28% women) referred for pre-CRT assessment were studied and divided into three groups: 1 (non-ischemic CM with LVNC, 11 patients), 2 (ischemic CM, 28 patients), and 3 (non-ischemic CM, 53 patients). All were studied by a 99mTc-MIBI gated-SPECT MPI at rest pre-CRT implantation and 6 ± 1 months after, including intraventricular dyssynchrony assessment by phase analysis. Quality of life was measured by the Minnesota Living with Heart Failure Questionnaire (MLHFQ). Results No differences in sex, atherosclerotic risk factors other than smoking habit, and MLHFQ results were found among groups. LVNC CM patients were younger, with greater QRS width and lower left ventricular ejection fraction (LVEF) at baseline, but the differences were not significant. No significant differences were found at baseline regarding ventricular function, although end-systolic volume was slightly higher in LVNC CM patients. Mean SRS was significantly higher (p < 0.0001) in ischemic patients (14.9) versus non-ischemic ones (8.7 in group 1 and 9 in group 2). At baseline, LVNC CM patients were significantly more dyssynchronous: Their phase standard deviation (PSD) was higher (89.5° ± 14.2°) versus groups 2 (65.2° ± 23.3°) and 3 (69.7° ± 21.7°), p = 0.007. Although the quality of life significantly improved in all groups, non-ischemic patients (with or without LVNC) showed a higher LVEF increase and volumes reduction at 6 months post-CRT. Dyssynchrony reduced post-CRT in all groups. Nevertheless, those more dyssynchronous at baseline (LVNC CM) exhibited the most significant intraventricular synchronism improvement: PSD was reduced from 89.5° ± 14.2° at baseline to 63.7° ± 20.5° post-CRT (p = 0.028). Six months post-CRT, 89% of patients were responders: 11 (100%) of those with LVNC CM, 25 (86%) of those with ischemic CM, and 47 (89%) of patients with non-ischemic CM. No patient with LVNC CM had adverse events during the follow-up. Conclusion CRT contributes to a marked improvement in non-ischemic CM patients with non-compaction myocardium. Phase analysis in gated-SPECT MPI is a valuable tool to assess the response to CRT.


Circulation ◽  
2008 ◽  
Vol 118 (suppl_18) ◽  
Author(s):  
Niels J Verouden ◽  
Bimmer E Claessen ◽  
René J van der Schaaf ◽  
Karel T Koch ◽  
Jan Baan ◽  
...  

Background Incomplete ST-segment deviation resolution (STR) after epicardial flow restoration may represent microvascular dysfunction and predicts an unfavorable outcome in patients with ST-segment elevation myocardial infarction (STEMI). From recently published data concerning STEMI patients that underwent primary percutaneous coronary intervention (PCI), increased mortality in patients with multivessel disease (MVD) was attributed to the presence of a chronic total occlusion (CTO) in a non-infarct-related artery (IRA). We evaluated whether the presence of MVD with or without a CTO in a non-IRA significantly contributes to incomplete STR in a large cohort of patients undergoing primary PCI for STEMI. Methods In this single-center study, 2127 STEMI patients underwent primary PCI between 2000 and 2006. The IRA and presence of MVD was determined during diagnostic angiography preceding primary PCI. MVD was assessed if ≥ 1 non-IRA showed ≥ 1 coronary stenosis of ≥ 70% and a CTO was defined as a 100% luminal narrowing in a non-IRA. STR was defined as the relative difference (in %) of the summed ST deviation between the pre-PCI and the immediately post-PCI 12-lead ECG. A post-PCI STR of ≥ 70% was considered complete. Results During emergency coronary angiography, singlevessel disease (SVD) was observed in 1474 (69.3 %) patients, MVD without a CTO in 433 (20.4 %) patients, and MVD with a CTO in a non-IRA in 220 (10.3 %) patients. MVD patients less frequently showed complete STR compared to patients with SVD (OR 1.2 95% CI, 1.0 – 1.5 p = 0.046). However, the occurrence of complete STR in SVD patients and MVD patients without a CTO was comparable (OR 1.1, 95% CI, 0.9 – 1.4 p = 0.43). In MVD patients with a CTO, STR was significantly less often complete compared to patients with SVD or with MVD without a CTO (OR 1.6 95% CI, 1.1 – 2.6 p = 0.01). Conclusion STEMI patients with MVD undergoing primary PCI showed complete STR less often compared to SVD patients. This effect is mainly due to a subgroup of MVD patients with a CTO in a non-IRA and not due to mere MVD.


Author(s):  
Amelia Jimenez-Heffernan ◽  
Sadaf Butt ◽  
Claudio T. Mesquita ◽  
Teresa Massardo ◽  
Amalia Peix ◽  
...  

Author(s):  
Piotr J. Slomka ◽  
Guido Germano ◽  
Daniel S. Berman

Gated MPS provides an accurate and reproducible method for measuring myocardial perfusion at stress and rest as well as LVEF, EDV, ESV and diastolic function. It also provides a means of assessing regional wall motion abnormality, either at rest or post-stress. These functions and perfusion measurements obtained from gated MPS complement each other in CAD diagnosis as well as risk stratification. This chapter presents a comprehensive review of techniques used in gated SPECT processing to quantify function and perfusion, including the latest techniques and developments.


2010 ◽  
Vol 55 (10) ◽  
pp. A89.E842
Author(s):  
William Lane Duvall ◽  
Lori B. Croft ◽  
Samantha Buckley ◽  
Eric Ginsberg ◽  
Tapan Godiwala ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document