scholarly journals Patient-specific computer modelling – its role in the planning of transcatheter aortic valve implantation

2016 ◽  
Vol 25 (2) ◽  
pp. 100-105 ◽  
Author(s):  
N. El Faquir ◽  
B. Ren ◽  
N. M. Van Mieghem ◽  
J. Bosmans ◽  
P. P. de Jaegere
2020 ◽  
Vol 2020 ◽  
pp. 1-22
Author(s):  
Adi A. Basri ◽  
Mohammad Zuber ◽  
Ernnie I. Basri ◽  
Muhammad S. Zakaria ◽  
Ahmad F. A. Aziz ◽  
...  

This study investigated the impact of paravalvular leakage (PVL) in relation to the different valve openings of the transcatheter aortic valve implantation (TAVI) valve using the fluid structure interaction (FSI) approach. Limited studies were found on the subject of FSI with regards to TAVI-PVL condition, which involves both fluid and structural responses in coupling interaction. Hence, further FSI simulation with the two-way coupling method is implemented to investigate the effects of hemodynamics blood flow along the patient-specific aorta model subjected to the interrelationship between PVL and the different valve openings using the established FSI software ANSYS 16.1. A 3D patient-specific aorta model is constructed using MIMICS software. The TAVI valve identical to Edward SAPIEN XT 26 (Edwards Lifesciences, Irvine, California), at different Geometrical Orifice Areas (GOAs), is implanted into the patient’s aortic annulus. The leaflet opening of the TAVI valve is drawn according to severity of GOA opening represented in terms of 100%, 80%, 60%, and 40% opening, respectively. The result proved that the smallest percentage of GOA opening produced the highest possibility of PVL, increased the recirculatory flow proximally to the inner wall of the ascending aorta, and produced lower backflow velocity streamlines through the side area of PVL region. Overall, 40% GOA produced 89.17% increment of maximum velocity magnitude, 19.97% of pressure drop, 65.70% of maximum WSS magnitude, and a decrement of 33.62% total displacement magnitude with respect to the 100% GOA.


Author(s):  
Simon H. Sündermann ◽  
Michael Gessat ◽  
Willibald Maier ◽  
Jörg Kempfert ◽  
Thomas Frauenfelder ◽  
...  

Objective We tested the hypothesis that simulated three-dimensional prosthesis overlay procedure planning may support valve selection in transcatheter aortic valve implantation (TAVI) procedures. Methods Preoperative multidimensional computed tomography (MDCT) data sets from 81 consecutive TAVI patients were included in the study. A planning tool was developed, which semiautomatically creates a three-dimensional model of the aortic root from these data. Three-dimensional templates of the commonly used TAVI implants are spatially registered with the patient data and presented as graphic overlay. Fourteen physicians used the tool to perform retrospective planning of TAVI procedures. Results of prosthesis sizing were compared with the prosthesis size used in the actually performed procedure, and the patients were accordingly divided into three groups: those with equal size (concordance with retrospective planning), oversizing (retrospective planning of a smaller prosthesis), and undersizing (retrospective planning of a larger prosthesis). Results In the oversizing group, 85% of the patients had new pacemaker implantation. In the undersizing group, in 66%, at least mild paravalvular leakage was observed (greater than grade 1 in one third of the cases). In 46% of the patients in the equal-size group, neither of these complications was observed. Conclusions Three-dimensional prosthesis overlay in MDCT-derived patient data for patient-specific planning of TAVI procedures is feasible. It may improve valve selection compared with two-dimensional MDCT planning and thus yield better outcomes.


Sign in / Sign up

Export Citation Format

Share Document