Diethylstilbestrol-associated hemolytic anemia with a positive direct antiglobulin test result

1989 ◽  
Vol 86 (5) ◽  
pp. 617-618 ◽  
Author(s):  
Craig S. Rosenfeld ◽  
Stephen J. Winters ◽  
Harry E. Tedrow
Author(s):  
Cristiane da Silva Rodrigues de Araújo ◽  
Bruna Accorsi Machado ◽  
Tamaris Fior ◽  
Júlia Mognon Mattiello ◽  
Mosseli Meinhart ◽  
...  

Blood ◽  
2012 ◽  
Vol 120 (21) ◽  
pp. 5159-5159
Author(s):  
Jitendra Mohan Khungar ◽  
Hara Prasad Prasad Pati ◽  
Manoranjan Mahapatra

Abstract Abstract 5159 Introduction: Auto Immune Hemolytic Anemia (AIHA) is one of the most common types of acquired hemolytic anaemias. Its main cause is auto antibody mediated rapid destruction of RBCs. Detection of these autoantibodies to erythrocytes is of fundamental importance for diagnosis. A number of methodologies have been tried for detection & evaluation of these autoantibodies. Demonstration of a positive Direct Antiglobulin Test (DAT) against these autoantibodies is an important serological assay in the diagnosis of auto immune hemolytic anemia (AIHA). This test is also considered as pathognomonic of immune-mediated hemolysis. This routinely used direct antiglobulin test (DAT) has the disadvantage of low sensitivity and does not detect low levels of red cell auto antibodies leading sometimes to false negative results. Flow cytometry can effectively diagnose such patients of auto immune hemolytic anemia with low levels of autoantibodies. Role of flow cytometry in the diagnosis of several non-malignant haematological disorders is being explored & present study has been conducted with the same objective. Aims & Objectives: This study was conducted with the following aims and objectives: •To assess the utility of flow-cytometry (FCM) in the diagnosis of suspected AIHA patients. •Compare the sensitivity of flow-cytometry (FCM) with Direct Antiglobulin Test (DAT) by Gel-card Test (GT). •To assess the positivity in DAT negative cases by flow-cytometry in suspected AIHA cases. Material & Methods: This was a prospective study, carried out in Haematology Deptt of All India Institute of Medical Sciences, where patients with suspected auto immune hemolytic anemia (AIHA) were studied during two years period. Blood samples of suspected patients of AIHA were tested by Gel Card Test as well as by Flow cytometry for detection of RBC bound IgG. Results: A total of 50 patients with suspected diagnosis of auto immune hemolytic anemia (AIHA) were studied by flow-cytometry as well as by Gel card test (GT) for detection of RBC bound IgG. Out of these 50 cases, 41 cases have turned out to be positive and 9 were negative by flow-cytometry. The quantification of positivity by flow-cytometry was obtained by calculating percentage fluorescence. The same 50 cases were also tested by Gel card test (GT). By Gel card test, out of 50 cases, 34 were positive & 16 were negative. Therefore, there were 7 cases which were negative for RBC bound IgG by Gel card test and these were positive by flow-cytometry. The flow cytometry figures of these cases will be shown & discussed in the presentation. Conclusions: Flow-cytometry is a reliable and sensitive method of detecting RBC-bound IgG antibodies for the diagnosis of auto immune hemolytic anemia. This can be used as a new routine diagnostic technique for auto immune hemolytic anemia. Disclosures: No relevant conflicts of interest to declare.


2020 ◽  
Vol 42 ◽  
pp. 382
Author(s):  
C.S.R. Araújo ◽  
J.M. Mattiello ◽  
L.L. Brittes ◽  
M. Meinhart ◽  
P. Bortolotti ◽  
...  

Blood ◽  
2009 ◽  
Vol 114 (22) ◽  
pp. 5091-5091
Author(s):  
Wilma Barcellini ◽  
Nicoletta Revelli ◽  
Francesca Guia Imperiali ◽  
Maria Antonietta Villa ◽  
Maria Cristina Manera ◽  
...  

Abstract Abstract 5091 Background The diagnosis of autoimmune hemolytic anemia (AIHA) is based on a positive direct antiglobulin test (DAT), which is performed by various methods with different sensitivity. Recently mitogen stimulated (MS)-DAT was suggested able to disclose a latent anti-erythrocyte autoimmunity Aims: To compare different traditional (tube, microcolumn and solid phase) and new (mitogen stimulated, MS)-DAT methods in different diagnostic conditions: 54 consecutive cases of hemolytic anemia of suspected autoimmune origin, 28 idiopathic AIHA in clinical remission, and 12 difficult cases of DAT-negative AIHA, and 2) to correlate results with hematologic and hemolytic parameters. Methods DAT tube, microcolumn, solid phase, and eluates were performed by standard techniques. MS-DAT was performed by stimulating whole blood with PHA, PMA and PWM and antibodies were detected by competitive solid phase ELISA. Results Forty out of 54 consecutive cases of suspected AIHA were positive by one or more tests namely 14 DAT-tube, 19 microcolumn, 19 solid phase and 35 MS-DAT. Among the 14 DAT-tube positive cases, 11 were confirmed by all test, and 3 by one or more (1 microcolumn, 1 solid phase, and 1 MS-DAT), eluates were positive in 11, and the majority of patients (10/14) showed hemolytic anemia. As regards the 26 DAT-tube negative cases, 7 were positive in microcolumn and solid-phase (eluates positive in 2/8, panreactive), and 16 in MS-DAT, although in both groups anemia and hemolytic signs were less clear. Mitogen stimulation increased the amount of RBC-bound IgG in all groups, suggesting that MS-DAT could disclose a latent autoimmunity. Tube-negative/other methods positive cases included patients with B-CLL, myelodysplasia/aplasia, and thalassemia intermedia, in which autoimmune phenomena are more frequently observed than overt clinical autoimmune diseases. MS-DAT failed to detect anti-erythrocyte antibodies in half cases AIHA in clinical remission which still were tube-positive. Finally, MS-DAT was the only positive test in 10 cases of AIHA of difficult diagnosis, and mitogen stimulation allowed the identification of autoantibody specificity in culture supernatants of 2 cases which gave weak positive results in microcolumn/solid phase only. Conclusion We concluded that a battery of tests rather than a single test is recommended for the diagnosis of AIHA, depending on the specific clinical context: tube is still a good choice for first screening, microcolumn and solid-phase, which are the automated routine, should be confirmed by a positive eluate to diagnose AIHA, although positivity without a clinical equivalent may be taken into account as part of an autoimmune habitus. MS-DAT could be considered as an additional test for selected cases of difficult diagnosis. Disclosures No relevant conflicts of interest to declare.


Sign in / Sign up

Export Citation Format

Share Document