Maintenance error reduction strategies in nuclear power plants, using root cause analysis

1989 ◽  
Vol 20 (2) ◽  
pp. 115-121 ◽  
Author(s):  
Tung-Ming Wu ◽  
Sheue-Ling Hwang
Author(s):  
Chen Qiang ◽  
Han Ning ◽  
Chen Weihan ◽  
Che Yinhui

Pipe rupture in the Condensate Extraction system (CEX) of nuclear power plants will lead to high oxygen content in the secondary circuit and therefore exacerbates equipment and pipeline corrosion. At the same time, there is a risk of loss of vacuum in the system, which has a direct impact on the safe and stable operation of nuclear power plants and will affect the economic benefits. In this paper, Equipment Failure Root Cause Analysis (ERCA) methodology is employed combined with metallography analysis (SEM analysis, XRD) and finite element simulation analysis, to investigate the root cause for drainage pipeline rupture in CEX System of Pressurized Water Reactor (PWR). Detailed analysis process of ERCA was introduced including RCA project establishment, data collection, failure modes analysis and so on. The most probable failure mode is pointed out through the investigation and evidence analyzed. It suggests that the improper design and the installation of limiting orifice plate should be the root cause. And corresponding corrective actions are put forward in details to prevent the recurrence.


Author(s):  
Che Yinhui ◽  
Guan Jianjun ◽  
Zu Shuai ◽  
Chen Qiang

Electric feedwater pump is an important feedwater equipment of nuclear power plants, and its reliability is directly related to the safe and steady operation of nuclear power plants and also economic benefits. In fact, corrosion of electric feedwater pump motor shaft occurs repeatedly, and even bearing shell in the motor can be burned out happen sometimes. This text sets out to analyze the cause of corrosion of electric feedwater pump motor shaft, identify the root cause, and further work out pertinent corrective actions based on the structure of the feedwater pump.


Author(s):  
Evy De Bruycker ◽  
Séverine De Vroey ◽  
Xavier Hallet ◽  
Jacqueline Stubbe ◽  
Steve Nardone

During the 2012 outage at Doel 3 (D3) and Tihange 2 (T2) Nuclear Power Plants (NPP), a large number of nearly-laminar indications were detected mainly in the lower and upper core shells. The D3/T2 shells are made from solid casts that were pierced and forged. Restart authorization in 2013 was accompanied by a number of “mid-term” requirements, to be completed during the first operating cycle after the restart. One of these requirements was the mechanical testing of irradiated specimens containing hydrogen flakes. These tests showed unexpected results regarding the shift in the Reference Temperature for Nil Ductility Transition (RTNDT) of the flaked material VB395 (Steam Generator shell rejected because of flakes) after irradiation. This paper presents the root cause analysis of this unexpected behaviour and its transferability (or not) to the D3/T2 Reactor Pressure Vessels (RPVs). A mechanistic and a manufacturing based approach were used, aiming at identifying the microstructural mechanisms responsible for the atypical embrittlement of VB395 and evaluating the plausibility of these mechanisms in the D3/T2 RPVs. This work was based on expert’s opinions, literature data and test results. Both flaked and unflaked samples have been investigated in irradiated and non-irradiated condition. All hydrogen-related mechanisms were excluded as root cause of the unexpected behaviour of VB395. Two possible mechanisms at the basis of the atypical embrittlement of VB395 were identified, but are still open to discussion. These mechanisms could be linked to the specific manufacturing history of the rejected VB395 shell. Since the larger than predicted shift in transition temperature after irradiation of VB395 is not linked with the hydrogen flaking and since none of the specific manufacturing history features that are possible root causes are reported for the D3/T2 RPVs, the D3/T2 shells should not show the unexpected behaviour observed in VB395.


2006 ◽  
Vol 321-323 ◽  
pp. 426-429
Author(s):  
Deok Hyun Lee ◽  
Myung Sik Choi ◽  
Do Haeng Hur ◽  
Jung Ho Han ◽  
Myung Ho Song ◽  
...  

Most of the corrosive degradations in steam generator tubes of nuclear power plants are closely related to the residual stress existing in the local region of a geometric change, that is, an expansion transition, u-bend, ding, dent, bulge, etc. Therefore, accurate information on a geometric anomaly in a tube is a prerequisite to the activity of a non destructive inspection for a precise and earlier detection of a defect in order to prevent a failure during an operation, and also for a root cause analysis of a failure. In this paper, a newly developed eddy current technique of a three-dimensional profilometry is introduced and the proof for the applicability of the technique to a plant inspection is provided. The quantitative profile measurement using a new eddy current probe was performed on steam generator expansion mock-up tubes with various geometric anomalies typically observed in the operating power plants, and the accuracy of the measured data was compared with those from the laser profilometry.


Author(s):  
James B. Riddle

Abstract This paper will examine semiconductor wear out at San Onofre Nuclear Generation Station (SONGS). The topics will include case studies, failure mechanisms, diagnostic techniques, failure analysis techniques and root cause corrective actions. Nuclear power plants are unique in that instrumentation and control circuits are continuously energized, are periodically tested, and have been in operation for greater than 25 years. Root cause evaluations at SONGS have identified numerous semiconductor failures due to wear out. Case studies include light output deterioration in opto-isolators, junction alloying failures of transistors and integrated circuits and parametric shifts in operational amplifiers. In most cases the devices do not fail catastrophically but degraded to the point of circuit level functional failure. Failure analysis techniques include circuit analysis, board level troubleshooting to identify the degraded components. Intermittent failures require power cycling, thermal cycling, and long term monitoring to identify the responsible components. Corrective actions for semiconductor wear out at SONGS include enhanced monitoring and proactive change out of identified part types.


2005 ◽  
Vol 129 (10) ◽  
pp. 1246-1251 ◽  
Author(s):  
Stephen S. Raab ◽  
Dana M. Grzybicki ◽  
Richard J. Zarbo ◽  
Frederick A. Meier ◽  
Stanley J. Geyer ◽  
...  

Abstract Context.—The utility of anatomic pathology discrepancies has not been rigorously studied. Objective.—To outline how databases may be used to study anatomic pathology patient safety. Design.—The Agency for Healthcare Research and Quality funded the creation of a national anatomic pathology errors database to establish benchmarks for error frequency. The database is used to track more frequent errors and errors that result in more serious harm, in order to design quality improvement interventions intended to reduce these types of errors. In the first year of funding, 4 institutions (University of Pittsburgh, Henry Ford Hospital, University of Iowa, and Western Pennsylvania Hospital) reported cytologic-histologic correlation error data after standardizing correlation methods. Root cause analysis was performed to determine sources of error, and error reduction plans were implemented. Participants.—Four institutions self-reported anatomic pathology error data. Main Outcome Measures.—Frequency of cytologic-histologic correlation error, case type, cause of error (sampling or interpretation), and effect of error on patient outcome (ie, no harm, near miss, and harm). Results.—The institutional gynecologic cytologic-histologic correlation error frequency ranged from 0.17% to 0.63%, using the denominator of all Papanicolaou tests. Based on the nongynecologic cytologic-histologic correlation data, the specimen sites with the highest discrepancy frequency (by project site) were lung (ranging from 16.5% to 62.3% of all errors) and urinary bladder (ranging from 4.4% to 25.0%). Most errors detected by the gynecologic cytologic-histologic correlation process were no-harm events (ranging from 10.7% to 43.2% by project site). Root cause analysis identified sources of error on both the clinical and pathology sides of the process, and error intervention programs are currently being implemented to improve patient safety. Conclusions.—A multi-institutional anatomic pathology error database may be used to benchmark practices and target specific high-frequency errors or errors with high clinical impact. These error reduction programs have national import.


Author(s):  
Guan Jianjun ◽  
Che Yinhui ◽  
Ma Lei

Incident investigation and root cause analysis (RCA) are widely used in nuclear power plant incident investigation and root cause confirmation. In this paper, based on the analysis literature reviews of root cause investigation of related incidents in IAEA (International Atomic Energy Agency), Europe and the United States, the analysis methods and techniques or tools of root causes in the world are studied, the incident investigation and analysis methods and techniques for root causes are analyzed and summarized. Through a comparison of various analysis methods and relevant application techniques and tools, differences between these root cause analysis techniques and tools are elaborated in terms of both concept and applicable application. In addition, application of RCA analysis methods and techniques is also briefed based on domestic RCA application practices.