The influence of hollow-cathode lamp line profiles upon analytical curves in atomic absorption spectroscopy

1974 ◽  
Vol 29 (11-12) ◽  
pp. 301-317 ◽  
Author(s):  
H.C. Wagenaar ◽  
I. Novotný ◽  
L. De Galan
1967 ◽  
Vol 21 (5) ◽  
pp. 329-331 ◽  
Author(s):  
G. Rossi ◽  
N. Omenetto

A demountable water-cooled hollow-cathode lamp for general use as a sharp-line source in atomic-absorption spectroscopy is described. The effective removal of the atomic vapors from the mouth of the cathode and the consequent possibility of raising the discharge current are stressed. The lamp has worked satisfactorily for 1 yr for 13 elements. Sensitivities either comparable to or exceeding those obtained with conventional tubes were observed.


1985 ◽  
Vol 39 (3) ◽  
pp. 519-526 ◽  
Author(s):  
M. D. Lowe ◽  
M. M. Sutton

The characteristics of a capillary discharge lamp, developed as a spectral source for the measurement of sulphur, phosphorus, selenium, and arsenic concentrations by flame atomic absorption spectroscopy, have been determined. Atomic spectral lines for each of the elements were produced when flowing mixtures of helium and vapor of the element, or a compound of the element, were passed through a quartz capillary discharge tube. Absorbance-concentration relationships, together with analytical sensitivities and detection limits, were obtained for sulphur, phosphorus, selenium, and arsenic with the use of a modified flame atomic absorption spectrophotometer, the optical system of which was purged with argon when necessary. The capillary discharge lamp readings were compared with measurements made under similar operating conditions with selenium and arsenic hollow cathode lamps. The capillary discharge lamp results were also compared with those obtained by other workers using electrodeless discharge lamps, modified hollow cathode lamps, and controlled temperature-gradient lamps. It was evident that the capillary discharge lamp possesses performance characteristics which make it potentially suitable as a spectral source for atomic absorption spectroscopy. Sensitivities and detection limits obtained with the use of this novel lamp were similar to those reported for other spectral sources.


1965 ◽  
Vol 19 (3) ◽  
pp. 65-68 ◽  
Author(s):  
Walter Slavin ◽  
David C. Manning

The use of neon as filler gas in lead hollow cathode lamps provides considerably more light energy than was available with earlier lamps. The spectroscopic performance of these lamps is reported as a function of gas fill, lamp current and spectral bandpass The detection limit for the lead analysis is shown to be 0.03 ppm lead in aqueous solutions with the new lamps and particular atomic absorption instrumentation


1977 ◽  
Vol 31 (2) ◽  
pp. 150-155 ◽  
Author(s):  
Tsutomu Araki ◽  
Teruo Uchida ◽  
Shigeo Minami

A novel use of pulsed hollow cathode lamps for the purpose of background correction with a dual wavelength atomic absorption spectrophotometer is described. The pulsed hollow cathode lamp in conjunction with a transient signal gating system behaves as if the analyte source and the background correction source are firing alternately in time. Determinations of Fe, Mg, and Cd are carried out in order to evaluate the performance in practical analyses. Procedures and results on the time-resolved measurement of emission spectra and resonance line profiles from several kinds of pulsed hollow cathode lamps are also demonstrated in detail.