Osteochondral fragment of the metacarpophalangeal joint

2022 ◽  
pp. 905-911
Author(s):  
Nick Carlson
2019 ◽  
Vol 80 (3) ◽  
pp. 246-258 ◽  
Author(s):  
Sarah Y. Broeckx ◽  
Frederik Pille ◽  
Simon Buntinx ◽  
Leen Van Brantegem ◽  
Luc Duchateau ◽  
...  

2019 ◽  
Vol 2019 ◽  
pp. 1-5
Author(s):  
Joana Monteiro Pereira ◽  
Miguel Quesado ◽  
Marcos Silva ◽  
João Das Dores Carvalho ◽  
Hélder Nogueira ◽  
...  

Complex dorsal metacarpophalangeal (MCP) joint dislocations as a result of hyperextension injuries are uncommon in the pediatric population and irreducible to closed maneuvers. Treatment of these complex lesions is invariably surgical, and dorsal or volar approaches are traditionally used. The authors describe a case of a 16-year-old male who suffered a fall onto his outstretched right hand in a soccer game. The patient presented to the ER with pain and deformity of the index finger MCP joint. Radiographs confirmed a complex MCP dislocation with a small osteochondral fragment. A lateral surgical approach was made, and interposition of the volar plate and an osteochondral fragment blocking the reduction were found. This versatile approach allowed access to volar and dorsal structures, minimizing the risk of surgical scarring and mobility arch limitation. To our knowledge, there are no reported cases regarding a lateral surgical approach.


2011 ◽  
Vol 02 (06) ◽  
pp. 353-355 ◽  
Author(s):  
Kelvin Ramsey ◽  
S. Overstall ◽  
A. Fleming

Author(s):  
Xiang Qian Shi ◽  
Ho Lam Heung ◽  
Zhi Qiang Tang ◽  
Kai Yu Tong ◽  
Zheng Li

Stroke has been the leading cause of disability due to the induced spasticity in the upper extremity. The constant flexion of spastic fingers following stroke has not been well described. Accurate measurements for joint stiffness help clinicians have a better access to the level of impairment after stroke. Previously, we conducted a method for quantifying the passive finger joint stiffness based on the pressure-angle relationship between the spastic fingers and the soft-elastic composite actuator (SECA). However, it lacks a ground-truth to demonstrate the compatibility between the SECA-facilitated stiffness estimation and standard joint stiffness quantification procedure. In this study, we compare the passive metacarpophalangeal (MCP) joint stiffness measured using the SECA with the results from our designed standalone mechatronics device, which measures the passive metacarpophalangeal joint torque and angle during passive finger rotation. Results obtained from the fitting model that concludes the stiffness characteristic are further compared with the results obtained from SECA-Finger model, as well as the clinical score of Modified Ashworth Scale (MAS) for grading spasticity. These findings suggest the possibility of passive MCP joint stiffness quantification using the soft robotic actuator during the performance of different tasks in hand rehabilitation.


2017 ◽  
Vol 22 (01) ◽  
pp. 35-38 ◽  
Author(s):  
Eichi Itadera ◽  
Takahiro Yamazaki

We developed a new internal fixation method for extra-articular fractures at the base of the proximal phalanx using a headless compression screw to achieve rigid fracture fixation through a relatively easy technique. With the metacarpophalangeal joint of the involved finger flexed, a smooth guide-pin is inserted into the intramedullary canal of the proximal phalanx through the metacarpal head and metacarpophalangeal joint. Insertion tunnels are made over the guide-pin using a cannulated drill. Then, a headless cannulated screw is placed into the proximal phalanx. All of five fractures treated by this procedure obtained satisfactory results.


2006 ◽  
Vol 31 (7) ◽  
pp. 1193-1196 ◽  
Author(s):  
J. Woodfin Kennedy ◽  
Lesley K. Wong ◽  
Behrooz Kalantarian ◽  
Leslie Turner ◽  
Cauley W. Hayes

2021 ◽  
pp. 175319342098185
Author(s):  
Xia Fang ◽  
Ping-tak Chan ◽  
Shengbo Zhou ◽  
Xinyi Dai ◽  
Ruiji Guo ◽  
...  

Correction of unequal radial polydactyly in which neither thumb duplicates possess both well-developed proximal and distal components, remains challenging. Current techniques using on-top plasty techniques require circumferential incisions, often resulting in postoperative swelling and dorsal scars. We described our experience using a volar approach to achieve better aesthetic and functional results. Twenty-one patients underwent this surgery between 2008 and 2018, with a mean follow-up of 5.1 years. The mean flexion–extension arc for the metacarpophalangeal joint was 75° and that of the interphalangeal joint was 43°. Mean percentage of key, tripod and tip pinch strength were 77%, 79% and 77%, respectively, when compared with the contralateral side. The Vancouver Scar Scale showed an average score of 1.2. We conclude from our study that the volar approach to on-top plasty is a good technique for the correction of unequal radial polydactyly, with good functional and aesthetic results. Level of evidence: IV


2021 ◽  
pp. 175319342110177
Author(s):  
Daniel B. Herren ◽  
Hajime Ishikawa ◽  
Marco Rizzo ◽  
Mark Ross ◽  
Michael Solomons

This review describes the different possibilities for arthroplasties at the proximal interphalangeal joint, thumb carpometacarpal joint, distal radioulnar joint, metacarpophalangeal joint and the wrist. For each joint, the indication for arthroplasty is explained, the surgical technique with the suitable implant is described and a brief summary of the outcomes reported in the literature is given.


Life Sciences ◽  
2002 ◽  
Vol 70 (20) ◽  
pp. 2445-2455 ◽  
Author(s):  
Paula A Jiménez ◽  
Lorena Garcı́a ◽  
H Adarmes ◽  
E González ◽  
M.A Valenzuela

Sign in / Sign up

Export Citation Format

Share Document