ELECTRIC POWER SYSTEM TRANSIENT STABILITY ESTIMATION AND CONTROL ACTION CHOICE

Author(s):  
V.M. Cheban ◽  
A.P. Dolgov ◽  
A.K. Landman ◽  
V.M. Levin
2018 ◽  
Vol 10 (11) ◽  
pp. 4140 ◽  
Author(s):  
Seungchan Oh ◽  
Heewon Shin ◽  
Hwanhee Cho ◽  
Byongjun Lee

Efforts to reduce greenhouse gas emissions constitute a worldwide trend. According to this trend, there are many plans in place for the replacement of conventional electric power plants operating using fossil fuels with renewable energy sources (RESs). Owing to current needs to expand the RES penetration in accordance to a new National power system plan, the importance of RESs is increasing. The RES penetration imposes various impacts on the power system, including transient stability. Furthermore, the fact that they are distributed at multiple locations in the power system is also a factor which makes the transient impact analysis of RESs difficult. In this study, the transient impacts attributed to the penetration of RESs are analyzed and compared with the conventional Korean electric power system. To confirm the impact of the penetration of RESs on transient stability, the effect was analyzed based on a single machine equivalent (SIME) configuration. Simulations were conducted in accordance to the Korean power system by considering the anticipated RES penetration in 2030. The impact of RES on transient stability was provided by a change in CCT by increasing of the RES penetration.


Author(s):  
Syarifuddin Nojeng ◽  
Syamsir Syamsir ◽  
Reny Murniati

Transient stability analysis is conducted to determine the ability of the electric power system in maintaining the operating stability after a major disturbance. The disturbance can be trigger an impact on the stability of the rotor angle, voltage, and system frequency which can cause loss of synchronization. In this paper, the impact of the interconnection of the Tombolo-Pao mini hydro power plant (MHPP) on the stability of the system was analyzed by several scenarios to determine the behavior of system parameters in a 20 kV system interconnection network. This research is an implementation of regulatory provisions relating to the study of the connection to the PLN distribution network through by regulator. Based on the result of simulation study, transient stability of generators at TomboloPao power plant about 0.1 second, will not occur with network configuration according to modeling activation of anti-islanding protection of Tombolo Pao Power Plant which is set by 2 second. The simulation results show that the location of the disturbance in the electric power system has been influenced by the behavior of the power plant (synchronous generator) which can lead to the instability of the micro-hydro connected to the micro-grid system 20 kV.


Sign in / Sign up

Export Citation Format

Share Document