TCT-145: New Generation Optical Coherence Tomography In Clinical Practice

2009 ◽  
Vol 104 (6) ◽  
pp. 58D
2020 ◽  
pp. 112067212090976
Author(s):  
Maria Cristina Savastano ◽  
Marco Rispoli ◽  
Bruno Lumbroso ◽  
Luca Di Antonio ◽  
Leonardo Mastropasqua ◽  
...  

Purpose: To assess the current role of fluorescein angiography after the introduction of optical coherence tomography angiography in real-life clinical practice. Methods: This was a multicentric retrospective observational study to evaluate the number of fluorescein angiography and optical coherence tomography angiography procedures performed by different devices from January 2013 to December 2018. The centers involved were Centro Italiano Macula (Rome), and ophthalmology departments of University “G. D’Annunzio” Chieti–Pescara (Chieti) and “Azienda Ospedaliero Universitaria Careggi” (Florence). Results: Out of 19,898 total fluorescein angiography procedures performed in the observation period, 3444 (17.3%) were in 2013, 3972 (19.9%) were in 2014, 3601 (18.1%) were in 2015, 3407 (17.2%) were in 2016, 3285 (16.5%) were in 2017, and 2189 (11%) were in 2018. Out of 7949 optical coherence tomography angiography procedures performed in the observation period, none were performed in 2013, 550 (6.9%) were in 2014, 908 (11.5%) were in 2015, 2098 (26.4%) were in 2016, 2090 (26.3%) were in 2017, and 2303 (28.9%) were in 2018. Conclusion: Fluorescein angiography procedures were performed less often after the introduction of optical coherence tomography angiography technology. The ease, speed, and safety of the optical coherence tomography angiography procedure in everyday clinical practice have facilitated more optical coherence tomography angiography application compared to fluorescein angiography in recent years. In the future, we will probably evaluate the different pathologies that still need an evaluation by fluorescein angiography.


2019 ◽  
Vol 40 (Supplement_1) ◽  
Author(s):  
Y Matsuhiro ◽  
M Nishino ◽  
H Nakamura ◽  
K Yasumoto ◽  
A Tanaka ◽  
...  

Abstract Background New generation drug eluting stents (DES) have improved target vessel failure as compared with early generation DES and bare metal stent. Contemporary several new generation DES are different each other regarding strut thickness and drug and polymer type. A little is known about which stent induces a more favorable vascular healing at follow up. Purpose In this study, we compared the vascular healing at 8-month follow up by optical coherence tomography (OCT) between 4 different kinds of new generation DES. Methods We enrolled 112 consecutive patients (121 lesions) who underwent PCI using 4 kinds of new generation DES including biodegradable-polymer everolimus-eluting stents (BP-EES), biodegradable-polymer sirolimus-eluting stents (BP-SES), durable-polymer everolimus-eluting stents (DP-EES) and durable-polymer zotarolimus-eluting stents (DP-ZES) and who underwent 8-month follow up angiogram and OCT between July 2016 and April 2018. We compared the OCT parameters including percentage of covered struts, uncovered struts, well-apposed and uncovered struts, malapposed strut and mean neointimal hyperplasia (NIH) thickness between them. Results BP-EES consisted of 29 lesions, BP-SES consisted of 25 lesions, DP-EES consisted of 38 lesions and DP-ZES consisted of 29 lesions. A total of 734 frames with 5163 struts in BP-EES, 481 frames with 4214 struts in BP-SES, 783 frames with 6119 struts in DP-EES and 583 frames with 4708 struts in DP-ZES were analyzed. As shown in a table, mean NIH thickness was significantly higher in BP-EES and BP-SES. Thus, we compared the OCT parameters between durable-polymer (DP) group including DP-ZES and DP-EES and biodegradable-polymer (BP) group including BP-EES and BP-SES. The percentage of uncovered struts was significantly lower and mean NIH thickness was significantly higher in BP group than DP group. Results of OCT parameters BP-EES (n=29) BP-SES (n=25) DP-EES (n=38) DP-ZES (n=29) P value BP group (n=54) DP group (n=67) P value Covered struts (%) 89.5±13.6 92.4±8.6 85.5±17.5 85.0±17.7 0.29 90.9±11.6 85.3±17.4 0.08 Uncovered struts (%) 8.8±10.8 7.1±8.7 14.5±17.5 15.0±17.7 0.14 8.0±9.9 14.7±17.4 0.03 Well-apposed and uncovered struts (%) 7.9±9.9 5.9±7.7 11.7±13.1 12.3±14.0 0.15 7.0±8.9 11.9±13.4 0.04 Malapposed struts (%) 0.8±1.6 1.3±2.2 2.7±5.8 2.7±4.7 0.33 1.0±1.9 2.7±5.3 0.07 Mean NIH thickness (μm) 102±57 121±48 78±28 88±33 <0.01 111±53 82±31 <0.01 Conclusion The present OCT study demonstrated that delayed neointimal healing characterized by the presence of uncovered struts and lower mean NIH thickness was less common in BP group than DP gruop. Biodegradable-polymer may be more favorable than durable-polymer from the point of view of vascular healing.


2016 ◽  
Vol 56 (3) ◽  
pp. 155-162 ◽  
Author(s):  
Luigi Antonio De Vitis ◽  
Lucia Benatti ◽  
Livia Tomasso ◽  
Giovanni Baldin ◽  
Adriano Carnevali ◽  
...  

2012 ◽  
Vol 157 (3) ◽  
pp. 341-346 ◽  
Author(s):  
Periklis A. Davlouros ◽  
Eleni Mavronasiou ◽  
Ioanna Xanthopoulou ◽  
Vasileios Karantalis ◽  
Grigorios Tsigkas ◽  
...  

2016 ◽  
Vol 17 (2) ◽  
pp. 71-73
Author(s):  
Luis Ortega-Paz ◽  
Salvatore Brugaletta ◽  
Hector M. Garcia-Garcia

Sign in / Sign up

Export Citation Format

Share Document