Comparison of the Performance of Two Different Spectral-Domain Optical Coherence Tomography Angiography Devices in Clinical Practice

2016 ◽  
Vol 56 (3) ◽  
pp. 155-162 ◽  
Author(s):  
Luigi Antonio De Vitis ◽  
Lucia Benatti ◽  
Livia Tomasso ◽  
Giovanni Baldin ◽  
Adriano Carnevali ◽  
...  
Author(s):  
Anna Lentzsch ◽  
Laura Schöllhorn ◽  
Christel Schnorr ◽  
Robert Siggel ◽  
Sandra Liakopoulos

Abstract Purpose To compare swept-source (SS) versus spectral-domain (SD) optical coherence tomography angiography (OCTA) for the detection of macular neovascularization (MNV). Methods In this prospective cohort study, 72 eyes of 54 patients with subretinal hyperreflective material (SHRM) and/or pigment epithelial detachment (PED) on OCT possibly corresponding to MNV in at least one eye were included. OCTA scans were acquired using two devices, the PLEX Elite 9000 SS-OCTA and the Spectralis SD-OCTA. Fluorescein angiography (FA) was used as reference. Two graders independently evaluated en face OCTA images using a preset slab as well as a manually modified slab, followed by a combination of en face and cross-sectional OCTA. Results Sensitivity (specificity) for the automated slabs was 51.7% (93.0%) for SS-OCTA versus 58.6% (95.3%) for SD-OCTA. Manual modification of segmentation increased sensitivity to 79.3% for SS-OCTA but not for SD-OCTA (58.6%). The combination of en face OCTA with cross-sectional OCTA reached highest sensitivity values (SS-OCTA: 82.8%, SD-OCTA: 86.2%), and lowest number of cases with discrepancies between SS-OCTA and SD-OCTA (4.2%). Fleiss kappa as measure of concordance between FA, SS-OCTA, and SD-OCTA was 0.56 for the automated slabs, 0.60 for the manual slabs, and 0.73 (good agreement) for the combination of en face OCTA with cross-sectional OCTA. Concordance to FA was moderate for the automated slabs and good for manual slabs and combination with cross-sectional OCTA of both devices. Conclusion Both devices reached comparable results regarding the detection of MNV on OCTA. Sensitivity for MNV detection and agreement between devices was best when evaluating a combination of en face and cross-sectional OCTA.


2020 ◽  
pp. 112067212090976
Author(s):  
Maria Cristina Savastano ◽  
Marco Rispoli ◽  
Bruno Lumbroso ◽  
Luca Di Antonio ◽  
Leonardo Mastropasqua ◽  
...  

Purpose: To assess the current role of fluorescein angiography after the introduction of optical coherence tomography angiography in real-life clinical practice. Methods: This was a multicentric retrospective observational study to evaluate the number of fluorescein angiography and optical coherence tomography angiography procedures performed by different devices from January 2013 to December 2018. The centers involved were Centro Italiano Macula (Rome), and ophthalmology departments of University “G. D’Annunzio” Chieti–Pescara (Chieti) and “Azienda Ospedaliero Universitaria Careggi” (Florence). Results: Out of 19,898 total fluorescein angiography procedures performed in the observation period, 3444 (17.3%) were in 2013, 3972 (19.9%) were in 2014, 3601 (18.1%) were in 2015, 3407 (17.2%) were in 2016, 3285 (16.5%) were in 2017, and 2189 (11%) were in 2018. Out of 7949 optical coherence tomography angiography procedures performed in the observation period, none were performed in 2013, 550 (6.9%) were in 2014, 908 (11.5%) were in 2015, 2098 (26.4%) were in 2016, 2090 (26.3%) were in 2017, and 2303 (28.9%) were in 2018. Conclusion: Fluorescein angiography procedures were performed less often after the introduction of optical coherence tomography angiography technology. The ease, speed, and safety of the optical coherence tomography angiography procedure in everyday clinical practice have facilitated more optical coherence tomography angiography application compared to fluorescein angiography in recent years. In the future, we will probably evaluate the different pathologies that still need an evaluation by fluorescein angiography.


Author(s):  
Pasha Anvari ◽  
Amin Najafi ◽  
Reza Mirshahi ◽  
Mahsa Sardarinia ◽  
Maryam Ashrafkhorasani ◽  
...  

Purpose: To compare the area of the foveal avascular zone (FAZ) in the superficial and deep retinal layers using two different spectral-domain optical coherence tomography angiography (OCTA) devices. Methods: A cross-sectional comparative study was conducted to obtain macular OCTA images from healthy subjects using Optovue RTVue XR Avanti (Optovue, Inc, Fremont, CA) and Spectralis HRA+OCTA (Heidelberg Engineering, Heidelberg, Germany). Two independent trained graders measured the FAZ area using automated slab segmentation. The FAZ area in the superficial and deep retinal layers were compared. Results: Twenty-three eyes of 23 subjects were included. The graders agreement was excellent (>0.86) for all measurements. The mean FAZ area was significantly larger at the superficial retinal layer as compared to the deep retinal layer on both devices (0.31 ± 0.08 mm2 vs 0.26 ± 0.08 mm2 in Optovue and 0.55 ± 0.16 mm2 vs 0.36 ± 0.13 mm2 in Spectralis, both P < 0.001). The mean FAZ area was significantly greater in the superficial and deep retinal layers using Spectralis as compared to Optovue measurements (P < 0.001 for both comparisons). Conclusion: In contrast to previous reports, the FAZ area was larger in the superficial retina as compared to deep retinal layers using updated software versions. Measurements from different devices cannot be used interchangeably.


Sign in / Sign up

Export Citation Format

Share Document