scholarly journals Corrigendum to ‘Impact of Patient Prosthesis Mismatch on the Outcome of Transcatheter Pulmonic Valve Implantation’ [The American Journal of Cardiology 151C (2021) 93-99]

Author(s):  
Daiji Takajo ◽  
Thomas J Forbes ◽  
Daisuke Kobayashi
Author(s):  
Matjaz Bunc ◽  
Miha Cercek ◽  
Tomaz Podlesnikar ◽  
Simon Terseglav ◽  
Klemen Steblovnik

Abstract Background Failure of a small surgical aortic bioprosthesis represents a challenging clinical scenario with valve-in-valve (ViV) transcatheter aortic valve implantation (TAVI) often resulting in patient-prosthesis mismatch. Bioprosthetic valve fracture (BVF) performed as a part of the ViV TAVI has recently emerged as an alternative approach with certain types of surgical bioprostheses. Case summary An 81-year-old woman with a history of three surgical aortic valve procedures presented with heart failure. Aortic bioprosthesis degeneration with severe stenosis and moderate regurgitation was found. The patient was deemed a high-risk surgical candidate and the heart team decided that ViV TAVI was the preferred treatment option. Due to the very small 19 mm stented surgical aortic bioprosthesis Mitroflow 19 mm (Sorin Group, Italy) we decided to perform BVF as a part of ViV TAVI to prevent patient-prosthesis mismatch. Since this was the first BVF procedure in our centre, an ex vivo BVF of the same kind of bioprosthetic valve was performed first. Subsequently, successful BVF with implantation of Evolut R 23 mm (Medtronic, USA) self-expandable transcatheter valve was performed. Excellent haemodynamic result was achieved and no periprocedural complications were present. The patient had an immediate major improvement in clinical status and remains asymptomatic after 6 months. Discussion Bioprosthetic valve fracture together with ViV TAVI is a safe and effective emerging technique for treatment of small surgical aortic bioprosthesis failure. Bioprosthetic valve fracture allows marked oversizing of implanted self-expandable transcatheter aortic valves, leading to excellent haemodynamic and clinical results. An ex vivo BVF can serve as an important preparatory step when introducing the new method.


2008 ◽  
Vol 86 (5) ◽  
pp. 1466-1472 ◽  
Author(s):  
Stefano M. Marianeschi ◽  
Francesco Santoro ◽  
Elena Ribera ◽  
Emanuele Catena ◽  
Gabriele Vignati ◽  
...  

2020 ◽  
Vol 125 (1) ◽  
pp. 135-139 ◽  
Author(s):  
Arka Chatterjee ◽  
Nirmanmoh Bhatia ◽  
Maria Gutierrez Torres ◽  
Marc G. Cribbs ◽  
David C. Mauchley ◽  
...  

2020 ◽  
Vol 21 (Supplement_1) ◽  
Author(s):  
S Muscoli ◽  
V Cammalleri ◽  
J Cosma ◽  
M Zuccaro ◽  
M Macrini ◽  
...  

Abstract BACKGROUND Early structural valve deterioration (SVD) frequently occurs in Mitroflow aortic bioprosthesis, especially for small sizes (19-mm and 21-mm), and it is associated with reduced overall survival. Treatment by percutaneous valve-in-valve (ViV) implantation is considered a challenging procedure. This is mainly due to an elevated risk of coronary ostia obstruction and high residual post-procedural mean gradients (mG), particularly when severe pre-existing patient-prosthesis mismatch (PPM) is present. PURPOSE Aim of our study was to assess the feasibility of transfemoral ViV in small Mitroflow aortic valves using supra-annular self-expanding valves, named CoreValve and Evolut R and Acurate neo and report the midterm clinical results by comparing serum natriuretic peptide type B levels (BNP) before the procedure and at a mean follow-up of 2 years. METHODS This is an observational study including 11 patients with stenotic-type SVD of small Mitroflow aortic valves, considered at high/prohibitive risk for surgical reoperation, who underwent ViV implantation between July 2012 and March 2018. We performed echocardiographic assessment of valve hemodynamics (according to VARC-2 definitions) before and after the procedure and during the follow-up. We used the BNP ratio (the ratio between measured serum BNP/NT-proBNP level and maximal normal level) to compare BNP results before the procedure and at follow-up. All-cause mortality during the hospitalization and follow-up was also reported. RESULTS The Mitroflow size was 19-mm in 4 patients and 21-mm in 7 patients. Pre-existing severe PPM was present in 4 patients and moderate PPM in 7. CoreValve 26 was implanted in 2 patients, EvolutR 23 in 5 and Acurate neo S in 4 patients. We reported no coronary obstruction, deaths or other major events during the hospitalization. At a mean follow-up of 2 years one patient died. The baseline aortic mG of 56 ± 19 mmHg has significantly reduced after the procedure to 16,6 ± 8 mmHg (p < 0.0001) and follow-up 29,6 ± 16 mmHg (p = 0.008). A post-procedural mG≥20, but <40 mmHg, was observed in 3 patients. BNP ratio at baseline was 14,6 ± 12; only one patient had a BNP ratio <3. At follow-up (n = 7 patients), BNP ratio was significantly lowered to 1,5 ± 1,08 (p = 0.01) with only one patient with a BNP ratio >3. Patients with mPG ≥20 mmHg did not show differences in terms of mortality and reduction of serum BNP levels. CONCLUSIONS In our experience the ViV procedure on small degenerated aortic Mitroflow bioprosthesis appears to be technically feasible and provides good midterm clinical results with a net reduction in serum BNP levels, although an increase in mG was observed. Even though a post-procedural mG ≥20 mmHg is considered indicative of suboptimal aortic valve hemodynamics (according to VARC-2 criteria), its correlation with worse outcomes remains unclear and deserves further investigations.


Sign in / Sign up

Export Citation Format

Share Document