44 Rapid Rule-Out of Type 1 Acute Myocardial Infarction Using a Contemporary Cardiac Troponin I Assay with Initial Undetectable Concentrations or Serial Concentrations Below the 99th Percentile

2016 ◽  
Vol 68 (4) ◽  
pp. S19
Author(s):  
S.W. Smith ◽  
Y. Sandoval ◽  
J. Cao ◽  
S.A. Love ◽  
K. Schulz ◽  
...  
Circulation ◽  
2017 ◽  
Vol 135 (17) ◽  
pp. 1597-1611 ◽  
Author(s):  
Jasper Boeddinghaus ◽  
Thomas Nestelberger ◽  
Raphael Twerenbold ◽  
Karin Wildi ◽  
Patrick Badertscher ◽  
...  

2013 ◽  
Vol 34 (suppl 1) ◽  
pp. P1300-P1300
Author(s):  
M. Rubini Gimenez ◽  
R. Twerenbold ◽  
T. Reichlin ◽  
B. Meller ◽  
B. Moehring ◽  
...  

2019 ◽  
Vol 40 (Supplement_1) ◽  
Author(s):  
C Bang ◽  
C Hansen ◽  
K Glerup Lauridsen ◽  
C Alcaraz Frederiksen ◽  
M Schmidt ◽  
...  

Abstract Introduction Current ESC guidelines have introduced a 0h/1h algorithm for accelerated rule-in or rule-out of acute myocardial infarction (MI) when using assay specific high-sensitive cardiac troponin I (hs-cTnI). Several studies have investigated the diagnostic performance and safety of this approach using different hs-cTnI assays. However, little is known of the diagnostic performance of a 0h/30min algorithm. Purpose To evaluate the diagnostic accuracy of early rule-in or rule-out of MI after 30 minutes by applying assay specific hs-cTnI cut-off values from a recently validated 0h/1h algorithm. Methods We prospectively enrolled chest pain patients suggestive of MI admitted to the Emergency Department. Patients underwent serial hs-cTnI measurements at admission (0 hour) and after 3 hours according to clinical practice. In addition, hs-cTnI measurements were performed after 30 minutes. The assay specific cut-off values from the 0h/1h algorithm were applied to the 30 minute cohort (figure 1). Final diagnosis was adjudicated independently by two physicians. Results In total, 943 patients were included. MI was the final diagnosis in 67 (7.1%) patients. Overall, absolute hs-cTnI values after 30 minutes were significantly higher in the MI group than in the non-MI group (19.2 (Q1:Q3) 2.7–75.3) ng/L versus 0.1 (0.2–0.7) ng/L, p<0.001). When applying the assay-specific hs-cTnI cut-off valuesfor the 0h/1h algorithmto the 30 minute patient cohort, 52.4% of patients were classified as rule-out with a negative predictive value of 100% (95% CI: 99.2–100). In total, 8.5% were classified as rule-in with a positive predictive value of 83.8% (95% CI: 74.2–90.3). Sensitivity was 100% (95% CI: 94.6–100) and specificity was 97.4% (95% CI: 95.7–98.6). Overall, 39.1% were assigned to the observational zone with a 3.5% prevalence of MI. Conclusions The use of assay specific hs-cTnI measurement at admission (0h) and 30 min later can be used to safely rule-out MI. This indicates that it might be safe to develop a 0h/30min algorithm and hereby reduce time to diagnosis even further. NCT03634384. Acknowledgement/Funding Randers Regional Hospital, A.P Møller Foundation, Boserup Foundation, Korning Foundation, Højmosegård Grant, Siemens Healthcare (TNIH assays), etc.


2016 ◽  
Vol 171 (1) ◽  
pp. 92-102.e5 ◽  
Author(s):  
Cedric Jaeger ◽  
Karin Wildi ◽  
Raphael Twerenbold ◽  
Tobias Reichlin ◽  
Maria Rubini Gimenez ◽  
...  

2018 ◽  
Vol 64 (5) ◽  
pp. 820-829 ◽  
Author(s):  
Jaimi Greenslade ◽  
Elizabeth Cho ◽  
Christopher Van Hise ◽  
Tracey Hawkins ◽  
William Parsonage ◽  
...  

Abstract BACKGROUND Low concentrations of cardiac troponin (cTn) have been recommended for rapid rule-out of acute myocardial infarction (AMI). We examined the Beckman Coulter Access high-sensitivity cardiac troponin I (hs-cTnI) assay to identify a single test threshold that can safely rule out AMI. METHODS This analysis used stored samples collected in 2 prospective observational studies. In all, 1871 patients presenting to a tertiary emergency department with symptoms of acute coronary syndrome had blood taken for measurement of cTnI on presentation. The endpoint was type 1 myocardial infarction (T1MI). Sensitivity and negative predictive value (NPV) were calculated for hs-cTnI values below the 99th percentile. RESULTS Ninety-eight patients had T1MI (5.2%), and 638 (34.1%) patients had an hs-cTnI &lt;2 ng/L (limit of detection), with sensitivity of 99.0% (95% CI, 94.4%–100%) and NPV of 99.8% (95% CI, 99.1%–100%). No hs-cTnI value above a concentration of 2 ng/L achieved sensitivity of 99%. However, an NPV of 99.5% was achieved at values &lt;6 ng/L. A cutoff &lt;6 ng/L enabled 1475 (78.8%) patients to be ruled out on presentation with sensitivity of 93.9% (95% CI, 87.1%–97.7%). CONCLUSIONS A single baseline cTn &lt;2 ng/L measured with the Access hs-cTnI assay performed well for rule-out of AMI. This cutoff concentration identified 99% of patients with AMI and could reduce the number of patients requiring lengthy assessment. A cutoff of &lt;6 ng/L yielded a high NPV but missed more cases of AMI than would be acceptable to clinicians.