Thermal-hydraulic performance optimization of inline and staggered fin-tube compact heat exchangers applying longitudinal vortex generators

2016 ◽  
Vol 95 ◽  
pp. 311-329 ◽  
Author(s):  
Leandro O. Salviano ◽  
Daniel J. Dezan ◽  
Jurandir I. Yanagihara
2021 ◽  
Vol 39 (5) ◽  
pp. 1523-1531
Author(s):  
Katherine Barquín ◽  
Alvaro Valencia

Over the last decades several studies have searched for improved Fin and Tube Heat Exchanger (FTHE) designs capable of providing the best thermo-hydraulic performance. The present study aims at quantifying and comparing the thermo-hydraulic performance of different FTHE configurations. Six different designs were analyzed. The first FTHE consisted of an in-line circular tube arrangement and the last one was a FTHE with staggered oval tube with two pairs of Delta Winglet Vortex Generators (DWVG) in common flow up–common flow down (CFU-CFD) configuration. The best performance was obtained using DWVG in CFU-CFD orientation. This configuration enabled a 90% increase of the thermal performance factor when compared with the first case, using only two pairs of vortex generator´s per tube.