Valve Thrombosis 7 Months After Transcatheter Aortic Valve Implantation

2014 ◽  
Vol 98 (3) ◽  
pp. 1079-1081 ◽  
Author(s):  
Clarence Pingpoh ◽  
Gregor Pache ◽  
Diab Nawras ◽  
Ludwig Guenkel ◽  
Kueri Sami ◽  
...  
Author(s):  
Helge Möllmann ◽  
David M. Holzhey ◽  
Michael Hilker ◽  
Stefan Toggweiler ◽  
Ulrich Schäfer ◽  
...  

Abstract Background Transcatheter aortic valve implantation (TAVI) has become standard treatment for elderly patients with symptomatic severe aortic valve stenosis. The ACURATE neo AS study evaluates 30-day and 1-year clinical and hemodynamic outcomes in patients treated with the ACURATE neo2 valve. Methods The primary endpoint of this single-arm multicenter study is 30-day all-cause mortality. Other key endpoints include device performance, echocardiographic measures assessed by an independent core laboratory, and VARC-2 clinical efficacy and safety endpoints through 12 months. Results The study enrolled 120 patients (mean age 82.1 ± 4.0 years; 67.5% female, mean baseline STS score 4.8 ± 3.8%). The VARC-2 composite safety endpoint at 30 days occurred in 13.3% of patients. All-cause mortality was 3.3% at 30 days and 11.9% at 1 year. The 30-day stroke rate was 2.5% (disabling stroke 1.7%); there were no new strokes between 30 days and 12 months. The rate of permanent pacemaker implantation was 15.0% (18/120) at 30 days and 17.8% (21/120) at 1 year. No patients required re-intervention for valve-related dysfunction and there were no cases of valve thrombosis or endocarditis. Patients demonstrated significant improvement in mean aortic valve gradient (baseline 38.9 ± 13.1 mmHg, 1 year 7.8 ± 3.5 mmHg; P < 0.001 in a paired analysis). In the overall population, paravalvular leak was evaluated at 1 year as none/trace in 60.5%, mild in 37.0%, and moderate in 2.5%; no patients had severe PVL. Conclusions One-year outcomes from the ACURATE neo AS study support the safety and performance of TAVI with the ACURATE neo2 valve. Graphic Abstract


2019 ◽  
Vol 8 (2) ◽  
pp. 280 ◽  
Author(s):  
Mark Ranasinghe ◽  
Karlheinz Peter ◽  
James McFadyen

Transcatheter aortic valve implantation (TAVI) has emerged as an important alternative to surgical aortic valve repair (SAVR) for patients with severe aortic stenosis. This rapidly advancing field has produced new-generation devices being delivered with small delivery sheaths, embolic protection devices and improved retrieval features. Despite efforts to reduce the rate of thrombotic complications associated with TAVI, valve thrombosis and cerebral ischaemic events post-TAVI continue to be a significant issue. However, the antithrombotic treatments utilised to prevent these dreaded complications are based on weak evidence and are associated with high rates of bleeding, which in itself is associated with adverse clinical outcomes. Recently, experimental data has shed light on the unique mechanisms, particularly the complex haemodynamic changes at sites of TAVI, that underpin the development of post-TAVI thrombosis. These new insights regarding the drivers of TAVI-associated thrombosis, coupled with the ongoing development of novel antithrombotics which do not cause bleeding, hold the potential to deliver newer, safer therapeutic paradigms to prevent post-TAVI thrombotic and bleeding complications. This review highlights the major challenge of post-TAVI thrombosis and bleeding, and the significant issues surrounding current antithrombotic approaches. Moreover, a detailed discussion regarding the mechanisms of post-TAVI thrombosis is provided, in addition to an appraisal of current antithrombotic guidelines, past and ongoing clinical trials, and how novel therapeutics offer the hope of optimizing antithrombotic strategies and ultimately improving patient outcomes.


2016 ◽  
Vol 207 ◽  
pp. 122-124 ◽  
Author(s):  
Stefan Toggweiler ◽  
Kai Schmidt ◽  
Matthias Paul ◽  
Florim Cuculi ◽  
Richard Kobza ◽  
...  

2021 ◽  
Vol 23 (Supplement_E) ◽  
pp. E142-E146
Author(s):  
Francesco Saia ◽  
Mateusz Orzalkiewicz

Abstract Transcatheter aortic valve implantation has become a valid alternative to surgical aortic valve replacement for patients with symptomatic severe aortic stenosis, regardless of baseline surgical risk. The incidence of periprocedural complications has steadily declined over the years, thanks to technical advancement of transcatheter heart valves, delivery systems, and increased operators’ experience. Beyond the most common periprocedural complications, there are a few uncommon but potentially severe complications that more often occur during follow-up, although they may also arise in the periprocedural phase. Stroke, infective endocarditis, valve thrombosis, and cognitive decline are among them. In this brief review, we describe the incidence, predictive factors, and potential preventive measures for those events.


2015 ◽  
Vol 68 (3) ◽  
pp. 198-204 ◽  
Author(s):  
Juan G. Córdoba-Soriano ◽  
Rishi Puri ◽  
Ignacio Amat-Santos ◽  
Henrique B. Ribeiro ◽  
Omar Abdul-Jawad Altisent ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document