Biologically competitive effect of Desulfovibrio desulfurican and Pseudomonas stutzeri on corrosion of X80 pipeline steel in the Shenyang soil solution

2022 ◽  
pp. 108051
Author(s):  
Qi Fu ◽  
Jin Xu ◽  
Boxin Wei ◽  
Qingyu Qin ◽  
Yunlong Bai ◽  
...  
2012 ◽  
Vol 47 (6) ◽  
pp. 441-445 ◽  
Author(s):  
C Q Ren ◽  
N Xian ◽  
X Wang ◽  
L Liu ◽  
Y P Zheng

2014 ◽  
Vol 28 (1) ◽  
pp. 93-102 ◽  
Author(s):  
Tang-Qing Wu ◽  
Mao-Cheng Yan ◽  
De-Chun Zeng ◽  
Jin Xu ◽  
Chang-Kun Yu ◽  
...  

2011 ◽  
Vol 335-336 ◽  
pp. 468-473 ◽  
Author(s):  
Chuan He ◽  
Xu Chen ◽  
Yang Xu ◽  
Zhi Yong Liu

X80 pipeline steel specimens were treated by electrochemical hydrogen charging under various current density and charging time. The polarization resistance and corrosion rate of X80 steel were analyzed in Yingtan simulated soil solution under the different hydrogen charging conditions. The results showed that hydrogen accelerated anodic dissolution and enhanced corrosion sensitivity. With hydrogen in the steel, the charge transfer resistance and polarization resistance decreased, double electric layer capacitor and corrosion current increased. The effects were enhanced with the increase of hydrogen charging time and current density.


2010 ◽  
Vol 146-147 ◽  
pp. 920-925 ◽  
Author(s):  
Yuan Cheng ◽  
Hong Ying Yu ◽  
Li Xin Zhang ◽  
Ying Wang ◽  
Xu Meng ◽  
...  

The stress corrosion cracking susceptibility of X80 pipeline steel was investigated in a simulated soil solution using slow strain rate tensile (SSRT) tests. The different potentials were applied in the tests. The fracture surfaces were observed using scanning electron microscopy (SEM). The X80 steel was susceptible to SCC in simulated solution. The SCC susceptibility had no apparent change with the anodic potentials applied. The fracture mechanism was anodic dissolution. However, the SCC susceptibility increased with the decrease of the cathodic potentials obviously. The cracking was induced by the Hydrogen diffusing into the metal.


2011 ◽  
Vol 197-198 ◽  
pp. 1549-1554 ◽  
Author(s):  
Yuan Cheng ◽  
Hong Ying Yu ◽  
Ying Wang ◽  
Xu Meng ◽  
Li Xin Zhang ◽  
...  

The stress corrosion cracking (SCC) susceptibility of X80 pipeline steel, which was used in the Second West-East Gas Pipeline, was investigated in simulated soil solution of Xinzhou in Hubei province of China. The SCC susceptibility was studied using the slow strain rate tensile (SSRT) tests in which different potentials were applied. The fracture surfaces were observed using SEM. X80 steel was susceptible to SCC in simulated solution. The SCC was not serious with the anodic potentials applied. The fracture mechanism was anodic dissolution. But the SCC was affected obviously with different cathodic potentials because of the different influence of the hydrogen.


2019 ◽  
Vol 66 (6) ◽  
pp. 868-878
Author(s):  
Yu Fu ◽  
Jie Kou ◽  
Cuiwei Du

Purpose Pipelines are seriously corroded due to the close distance between pipelines and high voltage transmission lines. The purpose of this paper is to study the influence of alternating current (AC) on corrosion behavior of X80 pipeline steel in coastal soil solution. Design/methodology/approach The corrosion behavior of X80 steel under different AC densities in coastal soil solution was investigated by electrochemical measurements and image processing technology. Furthermore, a quantitative description model of AC corrosion through fractal dimension of corrosion image was established. Findings The results show that under low AC density the X80 steel is mainly uniform corrosion, and once AC density reaches 150 A/m2, the corrosion morphology gradually turns to pitting corrosion with irregular circle. For another aspect, the fractal dimension of corrosion images shows that the two/three-dimensional fractal dimension increase with the increase of AC density, presenting a linear and an exponential relationship respectively. In addition, the variation of the three-dimensional fractal dimension is the same as that of average corrosion rate. The threshold of the increasing trend of fractal dimension as well as corrosion type is 150 A/m2. Originality/value The investigation provides a quantitative method to describe AC corrosion morphology through fractal dimension. Furthermore, the method is of benefit to process corrosion images automatically.


Sign in / Sign up

Export Citation Format

Share Document