Application of a digital guide in the removal of foreign body from the maxillofacial region

2019 ◽  
Vol 57 (7) ◽  
pp. 708-709
Author(s):  
W. Ma ◽  
L.D. Wang ◽  
Y. Liang ◽  
M. Li
2013 ◽  
Vol 14 (6) ◽  
pp. 1193-1196 ◽  
Author(s):  
Deepak Pandyan ◽  
N Nandakumar ◽  
Burhanuddin N Qayyumi

ABSTRACT The anatomic complexity of the maxillofacial region makes the retrieval of foreign bodies a daunting task for the maxillofacial Surgeon. Moreover the inability of 2-dimensional imaging to precisely locate foreign bodies makes it challenging. The anatomic proximity of critical structures and esthetic considerations limits the access and thus poses a greater challenge for the surgeon in cases of foreign body retrieval. Hereby we propose a simple technique and a case report to support, the retrieval of small (<5 mm greatest dimension) objects from the maxillofacial region. The present technique uses a 2 dimensional mobile C arm Fluoroscopy and a needle triangulation method to precisely locate a loosened miniplate screw in the mandibular angle region. How to cite this article Pandyan D, Nandakumar N, Qayyumi BN, Kumar S. C-Arm Fluoroscopy: A Reliable Modality for Retrieval of Foreign Bodies in the Maxillofacial Region. J Contemp Dent Pract 2013;14(6):1193-1196.


2017 ◽  
Vol 32 (1) ◽  
pp. 50
Author(s):  
Gilberto Leal Grade ◽  
Roberta Dalmolin Bergoli De Almeida ◽  
Leandro Calcagno Reinhardt ◽  
Marcos Antonio Torriani

Although injuries with the presence of foreign bodies in the maxillofacial region are relatively common in urgency and emergency services, they still pose a diagnostic challenge that is related to several factors, such as type of trauma, foreign body material, patient’s level of consciousness and anatomical site involved. A third of foreign bodies in the face are not detected upon initial examination and may remain in deep tissues until they are accidentally encountered by imaging tests for other purposes or until the patient shows symptoms such as pain or swelling. This article reports a case of a 9 cm piece of wood extracted from a patient’s middle third region of the left midface after 30 days of trauma occurrence, with associated infection suggesting a clinical picture of neoplasia.


2018 ◽  
Vol 65 (2) ◽  
pp. 111-112
Author(s):  
Masanori Tsukamoto ◽  
Jun Hirokawa ◽  
Takeshi Yokoyama

Retained foreign bodies sometimes occur in various surgical procedures and can lead to severe complications. Foreign bodies in the oral and maxillofacial region are not rare because of the use of many small items and the natural communication with the outside environment in some areas. We experienced a case of foreign body in the nasal cavity, which was discovered 1 year later at a second operation for hardware removal after maxillofacial surgery. A small, soft material is usually placed between the nasal endotracheal tube and nostril to avoid nasal pressure ulcer at the ala of nose after prolonged anesthesia after our group's experiencing some cases of this complication. The foreign body was found in the pharynx during induction of a second anesthesia. Attention should be directed to not leaving any materials in the patient after surgery. In addition to the normal counts of sponges, needles, etc, other small nonsurgical materials used should be recorded by medical staff to help ensure nothing is retained in the patient.


2020 ◽  
Vol 27 (2) ◽  
pp. 132-134
Author(s):  
Ji-Eun Choi ◽  
Hack Jung Kim ◽  
Seung-Kyu Chung

Foreign bodies in the sinus are rare entities that are often associated with trauma. This paper presents a case of a metallic foreign body that was retained without any symptoms for over 40 years. A skull X-ray and computed tomography scans showed blades of scissors inside the maxillary sinus, extending to the middle meatus without affecting vital structures. The foreign body was successfully removed by an endoscopic approach. There were no complications during and after the surgery. The presence of retained foreign bodies in the maxillofacial region is rarely discussed in previous publications. This manuscript focuses on the asymptomatic period of this foreign body and aims to discuss the necessity and feasibility of a wait-and-see approach in selected cases.


2018 ◽  
Vol 2018 ◽  
pp. 1-3
Author(s):  
Feride Fatma Görgülü ◽  
Orhan Görgülü ◽  
Ayşe Selcan Koç ◽  
Fatma Yasemin Öksüzler

Paranasal sinus (PNS) foreign bodies are not common. They are usually due to penetrating trauma and iatrogenic events. On imaging, radiopaque foreign bodies can easily be detected by X-ray views of PNS. CT scan may be necessary to evaluate the exact location of foreign body in some cases. Foreign body in the PNS should be removed as early as possible. Approach and technique of its removal depend upon its size, shape, and location. Nasal endoscopic examination can be helpful for these cases. We present a pediatric girl case of penetrating FB injury inserted into the maxillary sinus towards nasopharynx in a suddenly braking car.


Anaesthesia ◽  
2000 ◽  
Vol 55 (10) ◽  
pp. 1036-1037 ◽  
Author(s):  
A. Dutta ◽  
K. Jain ◽  
P. Chari
Keyword(s):  

1982 ◽  
Vol 15 (3) ◽  
pp. 553-559 ◽  
Author(s):  
Richard C. Bryarly ◽  
Frederick J. Stucker
Keyword(s):  

Sign in / Sign up