Myosonographic study of abdominal wall dynamics to assess donor site morbidity after microsurgical breast reconstruction with a DIEP or an ms-2 TRAM flap

2016 ◽  
Vol 69 (5) ◽  
pp. 598-603 ◽  
Author(s):  
K. Seidenstuecker ◽  
U. Legler ◽  
B. Munder ◽  
C. Andree ◽  
A. Mahajan ◽  
...  
2010 ◽  
Vol 43 (02) ◽  
pp. 166-172
Author(s):  
Chacko Cyriac ◽  
Ramesh Kumar Sharma ◽  
Gurpreet Singh

ABSTRACT Background: The pedicled TRAM flap has been a workhorse of autologous breast reconstruction for decades. However, there has been a rising concern about the abdominal wall donor site morbidity with the use of conventional TRAM flap. This has generally been cited as one of the main reasons for resorting to “abdominal wall friendly” techniques. This study has been undertaken to assess the abdominal wall function in patients with pedicled TRAM flap breast reconstruction. The entire width of the muscle and the overlying wide disk of anterior rectus sheath were harvested with the TRAM flap in all our patients and the anterior rectus sheath defect was repaired by a Proline mesh. Materials and Methods: Abdominal wall function was studied in 21 patients who underwent simultaneous primary unipedicled TRAM flap reconstruction after mastectomy for cancer. In all the patients, the abdominal wall defect was repaired using wide sheet of Proline mesh both as inlay and onlay. The assessment tools included straight and rotational curl ups and a subjective questionnaire. The abdominal wall was also examined for any asymmetry, bulge, or hernia. The minimal follow-up was 6 months postoperative. The objective results were compared with normal unoperated volunteers. Results and Conclusions: The harvesting the TRAM flap certainly results in changes to the anterior abdominal wall that can express themselves to a variable degree. A relatively high incidence of asymptomatic asymmetry of the abdomen was seen. There was total absence of hernia in our series even after a mean follow-up period of 15.5 months. A few patients were only able to partially initiate the sit up movement and suffered an important loss of strength. In most patients, synergists took over the functional movement but as the load increased, flexion and rotation performances decreased. The lack of correlation between exercise tests and the results of the questionnaire suggests that this statistically significant impairment was functionally not important. The patients encountered little or no difficulty in theis day-to-day activities. Our modification of use of a wide mesh as inlay and onlay repair minimizes the donor site morbidity. This also avoids maneuvers meant for primary closure of the rectus sheath defects, which can result in distortion of umbilicus. Therefore, in conclusion, the unipedicled TRAM flap should be regarded as a valuable option in breast reconstruction provided careful repair of the abdominal wall defect is undertaken using Proline mesh.


Microsurgery ◽  
2004 ◽  
Vol 24 (3) ◽  
pp. 174-181 ◽  
Author(s):  
Heike Benditte-Klepetko ◽  
O. Sommer ◽  
R. Steinbach ◽  
H. Czembirek ◽  
M. Deutinger

2006 ◽  
Vol 118 (Supplement) ◽  
pp. 102
Author(s):  
Liza C. Wu ◽  
Anureet Bajaj ◽  
David Woosuk Chang ◽  
Suyu Liu ◽  
Gregory D. Ayers ◽  
...  

2015 ◽  
Vol 3 (8) ◽  
pp. e476 ◽  
Author(s):  
Mario Rietjens ◽  
Francesca De Lorenzi ◽  
Manconi Andrea ◽  
Jean-Yves Petit ◽  
Prakasit Chirappapha ◽  
...  

2020 ◽  
Vol 9 (9) ◽  
pp. 3030
Author(s):  
Kathrin Bachleitner ◽  
Laurenz Weitgasser ◽  
Amro Amr ◽  
Thomas Schoeller

Various techniques for breast reconstruction ranging from reconstruction with implants to free tissue transfer, with the disadvantage of either carrying a foreign body or dealing with donor site morbidity, have been described. In patients who had a unilateral mastectomy and offer a contralateral mamma hypertrophy a breast reconstruction can be performed with the excess tissue from the hypertrophic side using the split breast technique. Here a local internal mammary artery perforator (IMAP) flap of the hypertrophic breast can be used for reconstruction avoiding the downsides of implants or a microsurgical reconstruction and simultaneously reducing the enlarged donor breast in order to achieve symmetry. Methods: Between April 2010 and February 2019 the split breast technique was performed in five patients after mastectomy due to breast cancer. Operating time, length of stay, complications and the need for secondary operations were analyzed and the surgical technique including flap supercharging were described in detail. Results: All five IMAP-flaps survived and an aesthetically pleasant result could be achieved using the split breast technique. An average of two secondary corrections to achieve better symmetry were necessary after each breast reconstruction. Complications included venous flap congestion, partial flap necrosis and asymmetry. No breast cancer recurrence was recorded. An overall approval of the surgical technique among patients was observed. Conclusions: The use of the contralateral breast for unilateral total breast reconstruction represents an additional highly useful technique for selected patients, is safe and reliable results can be achieved. Although this technique is carried out as a single-stage procedure, including breast reduction and reconstruction at the same time, secondary operations may be necessary to achieve superior symmetry and a satisfying aesthetic result. Survival of the IMAP-flaps can be improved by venous supercharging of the flaps onto the thoracoepigastric vein.


2013 ◽  
Vol 132 (6) ◽  
pp. 1383-1391 ◽  
Author(s):  
Edward I. Chang ◽  
Eric I. Chang ◽  
Miguel A. Soto-Miranda ◽  
Hong Zhang ◽  
Naveed Nosrati ◽  
...  

2021 ◽  
pp. 1107-1114
Author(s):  
Hinne A. Rakhorst

Microsurgery in general has made dramatic improvements over the past decades. This applies to microsurgery in general and to breast reconstructive surgery especially. The demand for autologous breast reconstruction has risen. Since the introduction of the free transverse rectus abdominis myocutaneous (TRAM) flaps, through the muscle-sparing TRAM, flaps designs have evolved into the current gold standard, the deep inferior epigastric perforator (DIEP) flap. From experiences and increasing numbers of flap procedures performed by surgeons, techniques became more familiar and part of standard care. These factors gave rise to the development of a growing number of areas of the body where tissues of interest can be harvested using perforator flap-based techniques. This chapter discusses the most common as well as the ‘rising stars’ in terms of flaps to be used as alternative flaps to the DIEP flap for breast reconstruction. It discusses practical issues on dissection as well as donor site morbidity.


Sign in / Sign up

Export Citation Format